chapter-420-3-16-a•Alabama Administrative Code Chapter 420-3-16-A — Appendices
Alabama Administrative Code Chapter 420-3-16-A — Appendices
chapter-420-3-16-aAla. Admin. Code ch. 420-3-16-ARegulation
420 Alabama Department of Public Health
Ala. Admin. Code r. 420-3-16-AA Appendix A - Animal Disease Control
Copies of the Bovine Tuberculosis Eradication: Uniform Methods and Rules (http://www.aphis.usda.gov/animal_health/ animal_diseases/ tuberculosis/downloads/tb-umr.pdf) and Brucellosis Eradication: Uniform Methods and Rules, (http://www.aphis.usda.gov/ animal diseases/brucellosis/ downloads/umr_bovine_bruc.pdf), current at the time of the adoption of these rules are available electronically using the hyperlinks above or may be obtained from your State Veterinarian:
Dr. Anthony G. Frazier Animal Industry Division Alabama Department of Agriculture & Industries 1445 Federal Drive Montgomery, Alabama 36107 or Veterinary Services Animal and Plant Health Inspection Service (APHIS) U.S. Department of Agriculture 4700 River Road, Unit 43 Riverdale, MD 20737 http://www.aphis.usda.gov/animal_health
It is recommended that regulatory agencies initiate and/or promote a mastitis control program. A well-planned and extended educational phase will encourage the support of producers and reduce the problems of enforcement.
The National Mastitis Council (NMC), 421 South Nine Mound Road, Verona, Wisconsin 53593 (www.nmconline.org), has studied a large number of existing control programs and has outlined a suggested flexible control program. In addition, review of the current knowledge of mastitis may be found in their publications: Current Concepts of Bovine Mastitis and Laboratory Handbook of Bovine Mastitis.
Sanitarians may find the screening test a useful device for detecting abnormal milk. Sample screening methods, as well as somatic cell diagnosis and reduction programs are discussed in the references above, as well as the Dairy Practices Council (DPC), 19 Titus Court, Richboro, Pennsylvania 18954 (www.dairypc.org) publication: The Fieldperson’s Guide to Troubleshooting High Somatic Cell Counts, DPC Guide Number 18.
Regulatory action should not be based on the use of mastitis screening tests alone. Screening tests should be used as an adjunct to a complete program of mastitis control and milking-time inspections.
History
- Author: G. M. Gallaspy, Jr.
- Authority: Code of Ala. 1975, §§22-2-2, 22-20-7.
- Repealed and New Rule: Filed October 18, 2018; effective December 2, 2018.
Ala. Admin. Code r. 420-3-16-AB Appendix B - Milk Sampling, Hauling, and Transportation
Milk sampling, hauling, and transport are integral parts of a modern dairy industry. Hauling, sampling, and transport can be categorized into three (3) separate functions: Dairy or industry plant samplers, bulk milk hauling and sampling, and milk transport from one (1) milk-handing facility to another.
I. MILK SAMPLING AND HAULING PROCEDURES
The dairy plant sampler is a person responsible for the collection of official samples for regulatory purposes outlined in 420-3-16-.07. These persons are employees of the Health Officer and are evaluated at least once each two (2) year period by an SSO or a properly delegated Sampling Surveillance Regulatory Official (dSSO). These individuals are evaluated using ADPH-FML-248A (Alabama Department of Public Health Bulk Milk Hauler Report and Sampler Evaluation Form), which is derived from the most current edition of Standard Methods for the Examination of Dairy Products SMEDP (refer to Appendix M).
Note: For the purposes of determining the inspection frequency for bulk milk hauler/samplers, industry plant samplers, and dairy plant samplers, the interval shall include the designated twenty-four (24) month period plus the remaining days of the month in which the inspection is due.
The bulk milk hauler or sampler is any person who collects official samples and may transport raw milk from a farm and/or raw milk products to or from a milk plant, receiving station, or transfer station and has in their possession a permit from any regulatory agency to sample such products. The bulk milk hauler or sampler occupies a unique position making this individual a critical factor in the current structure of milk marketing. As a weigher and sampler, they stand as the official, and frequently the only judge of milk volumes bought and sold. As a milk receiver, the operating habits directly affect the quality and safety of milk committed to their care. When the obligations include the collection and delivery of samples for laboratory analysis, the bulk milk hauler/sampler becomes a vital part of the quality control and regulatory programs affecting producer dairies. Section .04 of this rule requires that Health Officers establish criteria for issuing permits to bulk milk haulers or samplers. These individuals are evaluated at least once each two (2) year period using ADPH-FML-284A.
The industry plant sampler or bulk milk hauler or sampler is a person responsible for the collection of official samples for regulatory purposes at a milk plant, receiving station, or transfer station as outlined in Appendix N. These industry plant samplers are employees of the dairy plant, receiving station, or transfer station and are evaluated at least once each two (2) year period by an SSO or a dSSO. These industry plant samplers are evaluated using ADPH-FML-284A.
The milk tank truck driver is any person who transports raw or pasteurized milk or milk products to or from a milk plant, receiving station, or transfer station. Any transportation of a direct farm pickup requires the milk tank truck driver to have responsibility for accompanying official samples. The criteria for permitting these individuals should embrace at least the following:
TRAINING - To understand the importance of bulk milk collection and the techniques of sampling, including the use of an approved in-line sampler and approved aseptic samplers for milk tank trucks or for farm bulk milk tanks and/or silos, all bulk milk haulers or samplers and industry plant samplers shall be told why, and instructed how, in the proper procedures of picking up milk and the collection of samples. The Health Officer, dairy field person, route supervisors, or any appropriate person whose techniques and practices are known to meet the requirements can conduct this training. If the Health Officer does not conduct the training, the training shall be approved by or conducted under the supervision of the Health Officer. Training also frequently takes the form of classroom sessions in which the trainer describes pickup practices, demonstrates sampling and care of samples, and affords the candidate the opportunity for guided practice in these techniques. Basic considerations of sanitation and personal cleanliness, which are important to the protection of milk quality, are discussed here. Officials administering weights and measures may participate in these programs and provide instruction in the measuring of milk and the keeping of required records.
An examination, approved by the Health Officer shall be administered at the conclusion of this program. Candidates failing the exam, a score of less than 70 percent, shall be denied permits or licenses until indicated deficiencies are corrected. The examination should be adequate enough to determine if a bulk milk hauler or sampler is competent. The exam shall be composed of a minimum of twenty (20) total questions broken down into the following areas:
-
Six (6) questions relating to sanitation and personal cleanliness.
-
Six (6) questions relating to sampling and weighing procedures.
-
Four (4) questions relating to equipment, including proper use, care, cleaning, etc.
-
Four (4) questions relating to proper record keeping requirements.
Regularly scheduled refresher short courses by the regulatory agents and officials administering weights and measures would assist in maintaining and increasing the efficiency of the bulk milk hauler or sampler. Appropriate training should also be provided to industry plant samplers with regularly scheduled refresher short courses.
QUALIFICATIONS:
-
Experience - Experience may include a required period of observation during which the candidate accompanies a bulk milk hauler or sampler in the performance of their duties.
-
Personal References - Permit applications should be supported by suitable references testifying to the character and integrity of the candidate.
EVALUATION OF BULK MILK HAULER OR SAMPLER PROCEDURES
The routine inspection of bulk milk hauling or sampling procedures provides the Health Officer with an opportunity to check both the condition of the bulk milk hauler’s or sampler’s equipment and the degree of conformance with required practices.
The bulk milk hauler’s or sampler’s technique is best determined when the regulatory agent is able to observe the bulk milk hauler or sampler at one (1) or more farms. Each bulk milk hauler or sampler shall be inspected by the Health Officer prior to the issuance of a permit and at least once every twenty-four (24) months thereafter as referenced in 420-3-16-.06. The bulk milk hauler or sampler shall hold a valid permit prior to the collection of official samples. Health Officers may use inspections from any regulatory agency as a means of maintaining record requirements and enforcement.
Note: The option to utilize inspections of bulk haulers or samplers conducted by other regulatory agencies, as cited above, shall not be applicable to a third party certifier (TPC) authorized under the ICP.
The procedures for sampling and the care of samples should be in compliance with the current edition of SMEDP.
Specific items to be evaluated in determining compliance include:
-
Personal Appearance - Bulk milk haulers or samplers shall practice good hygiene; shall maintain a neat and clean appearance; and not use tobacco in the milkhouse.
-
Equipment Requirements
(a) Sample rack and compartment to hold all samples collected.
(b) Refrigerant to hold temperature of milk samples between 0°C- 4.5°C (32°F- 40°F).
(c) Sample dipper or other approved aseptic sampling devices of sanitary design and material approved by the Health Officer; clean and in good repair.
(d) Single use sample containers; properly stored.
(e) Calibrated pocket thermometer; certified for accuracy every six (6) months; accuracy ±1°C (2°F).
(f) Approved sanitizing agent and sample dipper container.
(g) Watch for timing milk agitation.
(h) Applicable sanitizer test kit.
(i) Single-service sanitary towels shall be provided for bulk tanks with a measuring rod.
- Milk Quality Checks
(a) Examine the milk by sight and smell for any off odor or any other abnormalities that would class the milk as not being acceptable. Reject if necessary.
(b) Wash hands thoroughly, and dry with a clean individual sanitary towel or other approved hand-drying device immediately prior to measuring and/or sampling the milk.
(c) Record milk temperature, collection time (optionally, in military time 24 hour clock), date of pick-up, and bulk milk hauler’s or sampler’s name and license or permit number on the farm weight ticket; monthly the hauler or sampler shall check the accuracy of the thermometer on each bulk tank and record results when used as a test thermometer. Accuracy of required recording thermometers shall be checked monthly against a standardized thermometer and recorded. Pocket thermometer shall be sanitized before use.
- Milk Measurements
(a) The measurement of the milk shall be taken before agitation. If the agitator is running upon arrival at the milkhouse, the measurement can be taken only after the surface of the milk has been quiescent.
(b) Carefully insert the measuring rod, after it has been wiped dry with a clean individual sanitary towel, into the tank. Repeat this procedure until two (2) identical measurements are taken. Record measurements on the farm weight ticket.
(c) Do not contaminate the milk during measurement.
- Universal Sampling System - When bulk milk haulers or samplers collect raw milk samples, the “universal sampling system” shall be employed, whereby samples are collected every time milk is picked up at the farm. This system permits the Health Officer, at its discretion, at any given time and without notification to the industry, to analyze samples collected by the bulk milk hauler/sampler. The use of the “universal sample” puts more validity and faith in samples collected by industry personnel. The following are sampling procedures:
(a) Pick-up and handling practices are conducted to prevent contamination of milk contact surfaces.
(b) The milk shall be agitated a sufficient time to obtain a homogeneous blend. Follow the Health Officer’s and/or manufacturer’s guidelines or when using an approved aseptic sampling device, follow the specified protocol and Standard Operating Procedure (SOP) for that device.
(c) While the farm bulk milk tank and/or silo are being agitated, bring the sample container, dipper, dipper container, and sanitizing agent for the outlet valve, or single-service sampling tubes into the milkhouse aseptically. Remove the cap from the farm bulk milk tank and/or silo outlet valve and examine for milk deposits or foreign matter and then sanitize if necessary. Protect the hose cap from contamination when removing it from the transfer hose and during storage.
(d) The sample may only be collected after the milk has been properly agitated or when using an approved aseptic sampling device, follow the specified protocol and SOP for that device. Remove the dipper or sampling device from the sanitizing solution or sterile container and rinse at least twice in the milk.
(e) Collect a representative sample or samples from the farm bulk milk tank and/or silo by using a sample dipper or other approved aseptic sampling device (refer to Section IV Requirements for Using An Approved Aseptic Sampler for Farm Bulk Milk Tanks and Silos of Appendix B for the specific protocol for the use of approved aseptic sampling devices). When transferring milk from the sampling equipment, caution should be used to assure that milk is not spilled back into the farm bulk milk tank and/or silo. Do not fill the sampling container more than three-quarters (¾) full. Close the cover on the sample container.
(f) The sample dipper shall be rinsed free of milk and placed in its carrying container.
(g) Close the cover or lid of the farm bulk milk tank.
(h) The sample shall be identified with the producer’s number at the point of collection.
(i) A temperature control sample shall be taken at the first stop of each load. This sample shall be labeled with collection time (optionally, in military time twenty-four [24] hour clock), date, temperature, and producer and bulk milk hauler or sampler identification.
(j) Place the sample or samples immediately into the sample storage case.
- Pump-Out Procedures
(a) Once the measurement and sampling procedures are completed, with the agitator still running, open the outlet valve and start the pump. Turn off the agitator when the level of milk is below the level that will cause over-agitation.
(b) When the milk has been removed from the tank, disconnect the hose from the outlet valve and cap the hose.
(c) Observe the inside surfaces of the bulk tank for foreign matter or extraneous material and record any objectionable observations on the farm weight ticket.
(d) With the outlet valve open, thoroughly rinse the entire inside the surface of the tank with warm water.
- Sampling Responsibilities
(a) All sample containers and single-service sampling tubes used for sampling shall comply with all the requirements that are in the current edition of SMEDP. Samples shall be cooled to and held between 0°C (32°F) and 4.5°C (40°F) during transit to the laboratory.
(b) Means shall be provided to properly protect the samples in the sample case. Keep refrigerant at an acceptable level.
(c) Racks shall be provided so that the samples are properly cooled in an ice bath.
(d) Adequate insulation of the sample container box or ice chest shall be provided to maintain the proper temperature of the samples throughout the year.
The SSO conducts periodic evaluations of sampling procedures. This program will promote uniformity and compliance of sample collection procedures.
II. REQUIREMENTS FOR USING AN APPROVED IN-LINE SAMPLER
A protocol specific to each milk producer who direct loads milk tank trucks (through by-passing the use of farm bulk milk tanks or silos) while utilizing an approved in-line sampler shall be developed by the Health Officer in cooperation with the sampling equipment manufacturer, the milk buyer, the milk producer, and the FDA. As a minimum, the protocol should include the following:
-
A description of how the milk sample is to be collected, identified, handled, and stored.
-
A description of the means used to refrigerate the sample collection device and milk sample collection container throughout the milk sample collection period.
-
A means to monitor the sampler device temperature and milk sample temperature and the milk temperature.
-
A description of how and when the sampler is to be cleaned and sanitized, if not of a single use design.
-
A listing of the licensed bulk milk haulers or samplers who have been trained to maintain, operate, clean, and sanitize the sample collection device as well as to collect, identify, handle, and store the milk sample.
-
A description of the method and means that will be used to determine weight of the milk on the milk tank truck.
III. REQUIREMENTS FOR USING AN APPROVED ASEPTIC SAMPLER FOR MILK TANK TRUCKS
A protocol specific to each milk plant in which industry plant samplers utilize an approved aseptic sampler shall be developed by the Health Officer in cooperation with the sampling equipment manufacturer, the milk plant, and the FDA. As a minimum, the protocol should include the following:
- A description of how the milk sample is to be collected, identified, handled, and stored.
(a) The aseptic sampler fitting shall be installed according to the manufacturer’s recommendations and in a manner that is compatible with its intended use.
(b) The aseptic sampler septum shall be installed according to the manufacturer’s instructions.
(c) Transfer of milk is achieved using an SOP specific to the aseptic sampler.
(d) An appropriate device, i.e., a syringe, shall be used to transfer the milk.
-
A description of how and when the aseptic sampler is to be cleaned and sanitized, if not of a single use design, as per the manufacturer’s instructions.
-
A listing of the industry plant samplers who have been trained to maintain, operate, clean, and sanitize the aseptic sampler as well as to collect, identify, handle, and store the milk sample.
IV. REQUIREMENTS FOR USING AN APPROVED ASEPTIC SAMPLER FOR FARM BULK MILK TANKS AND/OR SILOS
A protocol specific to each milk producer in which the milk producer, who transports milk only from his/her own dairy farm, or bulk milk haulers or samplers utilize an approved aseptic sampler shall be developed by the Health Officer in cooperation with the sampling equipment manufacturer, the milk producer and the FDA. As a minimum, the protocol should include the following:
- A description of how the milk sample is to be collected, identified, handled, and stored.
(a) The aseptic sampler fitting shall be installed according to the manufacturer’s recommendations and in a manner that is compatible with its intended use and does not create a dead end.
(b) The aseptic sampler septum shall be installed according to the manufacturer’s instructions.
(c) Transfer of milk is achieved using an SOP specific to the aseptic sampler.
-
A description of how and when the aseptic sampler is to be cleaned and sanitized, if not of a single use design, as per the manufacturer’s instructions.
-
A listing of the milk producer, who transports milk only from his/her own dairy farm, and/or licensed bulk milk haulers or samplers who have been trained to maintain, operate, clean, and sanitize the aseptic sampling device as well as collect, identify, handle, and store the milk sample.
V. REQUIREMENTS FOR THE SAMPLING OF RAW SHEEP MILK THAT HAS BEEN FROZEN PRIOR TO BEING TESTED FOR APPENDIX N DRUG RESIDUE
Raw sheep milk samples that have previously been frozen may be tested for Appendix N drug residue provided that the sampling protocol shall be approved by the Health Officer in which the dairy farm is located. The sampling protocol shall address the following items:
-
Samples shall be taken by a bulk milk hauler or sampler that is permitted by the Health Officer in which the dairy farm is located.
-
The sampling protocol shall assure that representative samples are taken.
-
A storage protocol that assures that the raw sheep milk and samples are frozen within 24 hours of sample collection in accordance with the handling of the negative control as specified in the FDA/NCIMS 2400 Form for the test kit that is being used.
-
The collected raw sheep milk and samples are stored in a freezer(s) that is properly maintained and temperature monitored in accordance with the FDA/NCIMS 2400 Form General Requirements.
-
Samples delivered to the testing laboratory for testing within sixty (60) days of the freezing of the raw sheep milk.
-
An appropriate sample chain-of-custody shall be utilized to assure sample identification and handling.
-
Copies of the approved sampling protocol shall be on file with the Health Officer and shall be available at the dairy farm, receiving milk plant, and the laboratory performing the testing. If a copy of the sampling protocol is not available at the dairy farm, receiving milk plant, or laboratory performing the testing, a copy shall be made available within twenty-four (24) hours of being requested by the Health Officer.
Note: If the sampling protocol has not been approved by the Health Officer; is not being followed; the sampling protocol has been modified without the Health Officer’s approval; or the dairy farm, receiving milk plant or laboratory performing the testing does not obtain a copy within twenty-four (24) hours of being requested by the Health Officer, it shall be considered an Appendix N violation for the dairy farm and/or receiving milk plant.
VI. MILK TANK TRUCK PERMITTING AND INSPECTION
Milk tank trucks shall be evaluated annually using the requirements established in 420-3-16-.04 and 420-3-16-.06 using the ADPH-FML-248B.
PERMITTING - Each milk tank truck shall bear a permit for the purpose of transporting milk and/or milk products (refer to 420-3-16-.04). The permit shall be issued to the owner of each milk tank truck by an authorized regulatory agency. The permit identification and regulatory agency issuing the permit shall be displayed on the milk tank truck. It is recommended that this permit be renewed each year pending satisfactory completion of an inspection as outlined in the following Inspection Section.
RECIPROCITY - Each permit shall be recognized by other regulatory agencies under the reciprocal agreements of the NCIMS and supporting documents of this rule. A milk tank truck need only bear one (1) permit from an appropriate Regulatory agency. A milk tank truck may be inspected at any time when deemed appropriate by the Health Officer. Absent proof of a current permit and current inspection, when the milk tank truck is inspected by a Regulatory agency other than the permitting agency, an inspection fee may be charged to the owner of the milk tank truck. This is necessary to allow a milk tank truck to pickup and deliver in several jurisdictions without the need for more than one (1) permit. A Health Officer may have the option of inspecting any milk tank truck at any time when milk and milk products are transported in or out of a particular jurisdiction. It is the responsibility of the milk tank truck owner or operator to maintain a current proof of inspection to avoid a re-inspection fee. Disputes concerning reciprocal agreements on milk tank truck inspection between regulatory agencies may be tendered to the Chair of the NCIMS or the Chair’s designee for resolution.
INSPECTION - Each milk tank truck shall be inspected at least once each year by a regulatory agency (refer to 420-3-16-.06). A copy of the current inspection report shall accompany the milk tank truck at all times, or the tank shall bear an affixed label, which identifies the regulatory agency with the month and year of inspection. The affixed label shall be located near the tank outlet valve or on the front left side of the milk tank truck bulkhead. When significant defects or violations are encountered by a regulatory agency, a copy of the report shall be forwarded to the permitting regulatory agency and also carried on the milk tank truck until the violations are corrected.
Milk tank truck inspections shall be conducted in a suitable location, i.e., a dairy plant, receiving, or transfer station or milk tank truck cleaning facility. Inspections may not require entry of confined spaces as defined by the Occupational Safety and Health Administration (OSHA) standards. When significant cleaning, construction, or repair defects are noted, the milk tank truck shall be removed from service until proper confined entry safety requirements can be satisfied to determine cleaning or repairs needed. Cleaning or repairs may be verified by a qualified individual to the satisfaction of the Health Officer.
Inspection reports completed by regulatory agencies other than the permitting agency shall be forwarded to the permitting agency for verification of inspection as required in the Permitting Section of this appendix. The permitting agency may use these reports to satisfy permit requirements.
MILK TANK TRUCK STANDARDS - All items of ADPH-FML248B fall into the categories of “Compliance,” “Non-Compliance,” or “Not Applicable” as determined during the inspection.
The following Items relate to ADPH-FML-248B:
- Samples and sampling equipment (when provided).
(a) Sample containers shall be stored to preclude contamination.
(b) The sample box shall be in good repair and kept clean.
(c) Sample transfer instrument shall be cleaned and sanitized to ensure that proper samples are collected.
(d) The sample transfer instrument container is provided and adequate means for maintaining sanitizer solutions is on hand.
(e) The samples are properly stored to preclude contamination.
(f) The sample storage compartment shall be clean.
(g) Samples are maintained at an acceptable temperature 0°C-4.5°C (32°F-40°F) and a temperature control sample is provided.
(h) An approved thermometer is available for use by the sampler. The accuracy of the thermometer is checked each six (6) months with the results and date recorded on the carrying case.
- Product Temperature 7°C (45°F) or Less
(a) The product temperature shall meet all the requirements of 420-3-16-.7, Items 18r-Raw Milk Cooling and 17p-Cooling of Milk and Milk Products.
(b) Product that remains in external transfer systems that exceeds 7°C (45°F) is discarded. This includes pumps, hoses, air elimination equipment, or metering systems.
- Equipment Construction, Cleaning, Sanitizing, and Repair: Items a. through l. on ADPH-FML-248B shall be evaluated according to the following criteria:
(a) Construction and Repair Requirements.
(1) The milk tank truck and all appurtenances shall meet applicable requirements of 420-3-16-.10(10), Item 10p-Sanitary Piping and 420-3-16-.10(11). Construction and Repair of Containers and Equipment. Equipment manufactured in conformity with 3-A Sanitary Standards, complies with sanitary design and construction requirements.
(2) The interior of the milk tank trucks shall be constructed of smooth, non-absorbent, corrosion-resistant, non-toxic material; and it shall be maintained in good repair.
(3) The appurtenances of the milk tank truck includes aseptic samples, if applicable, hoses, pumps, and fittings, shall be constructed of smooth, non-toxic cleanable material; and shall be maintained in good repair. Where flexibility is required, the fluid transfer system shall be free draining and so supported to maintain uniform slope and alignment. They shall be easily disassembled and accessible for inspection.
(4) The cabinet portion(s) of the tank used for the storage of appurtenances and sampling equipment, where applicable, shall be constructed to preclude contamination by dust, dirt; be clean; and in good repair.
(5) The milk tank truck dome lid assembly, vent, and dust cover shall be designed to protect the tank and milk from contamination.
(b) Cleaning and Sanitizing Requirements
-
The milk tank truck and all of its appurtenances shall be cleaned and sanitized in accordance with applicable requirements of 420-3-16-.10(12), Item 12p-Cleaning and Sanitizing of Containers and Equipment.
-
The milk tank truck shall be cleaned and sanitized prior to its first use. When the time elapsed after cleaning and sanitizing, and before its first use, exceeds ninety-six (96) hours the tank shall be re-sanitized.
-
It is allowable to pickup multiple loads continuously within a twenty-four (24) hour period, provided the milk tank truck is washed after each day’s used.
-
Exterior Condition of Tank - The exterior of the milk tank truck is properly constructed and in good repair. Defects and damage that would adversely affect products contained in the milk tank truck are pointed out on ADPH-FML-248B and corrective actions are prescribed. Cleanliness of the milk tank truck exterior is evaluated with consideration for existing weather and environmental conditions.
-
Wash and Sanitize Record
(a) The bulk milk hauler or sampler shall be responsible for assuring that the milk tank truck has been properly cleaned and sanitized at a permitted milk plant, receiving station, transfer station, or milk tank truck cleaning facility. A milk tank truck without proper cleaning and sanitizing documentation shall not be loaded or unloaded until the proper cleaning and sanitization can be verified.
Note: The option to use non-IMS listed milk tank truck cleaning facilities, as cited in a. above, shall not be applicable to a TPC authorized under the ICP.
(b) A cleaning and sanitizing tag shall be affixed to the outlet valve of the milk tank truck until the milk tank truck is next washed and sanitized. When the milk tank truck is washed and sanitized, the previous cleaning and sanitizing tag shall be removed and stored at the location where the milk tank truck was washed for a period of not less than fifteen (15) days.
(c) The following information shall be recorded on the cleaning and sanitization tag:
(1) Identification of the milk tank truck.
(2) Date and time (optionally, in military time [24] hour clock) of day the milk tank truck was cleaned and sanitized.
(3) Location where the milk tank truck was cleaned and sanitized.
(4) Signature or initials of the person who cleaned and sanitized the milk tank truck.
(d) The maintenance of all information on the cleaning and sanitizing tag shall be the responsibility of the bulk milk hauler or sampler or the milk tank truck operator.
(e) States shall submit to the NCIMS Executive Secretary an updated list of all currently permitted non-IMS listed milk tank truck cleaning facilities. The list is to be submitted for publication on the NCIMS web site.
- Location of Last Cleaning and Sanitizing
The location of the last cleaning and sanitizing shall be verified by the Health Officer during any milk tank truck inspection and recorded on the ADPH-FML-248B.
- Labeling - The maintenance of all pertinent information on all shipping documents, shipping invoices, bills of lading, or weight tickets is the responsibility of the bulk milk hauler/sampler. A milk tank truck transporting raw, heat-treated, or pasteurized milk, and milk products to a milk plant from another milk plant, receiving station, or transfer station is required to be marked with the name and address of the milk plant or hauler and the milk tank truck shall be under a proper seal. All shipping documents shall contain the following information as outlined in 420-3-16-.05:
(a) Shipper’s name, address, and permit number - Each milk tank truck load of milk shall include the IMS BTU identification number(s) or the IMS listed milk plant number for farm groups listed with a milk plant on the farm weight ticket or manifest;
(b) Permit identification of the hauler, if not an employee of the shipper.
(c) Point of origin of shipment.
(d) Milk tank truck identification number.
(e) Name of product.
(f) Weight of product.
(g) Temperature of product when loaded.
(h) Date of shipment.
(i) Name of supervising regulatory agency at the point of origin of shipment.
(j) Whether the contents are raw, pasteurized, or in the case of cream, lowfat or skim milk, whether it has been heat-treated.
(k) Seal number on inlet, outlet, wash connections, and vents; and
(l) Grade of product.
All information contained on the above described documents shall be verified by the regulatory agency and recorded on the appropriate inspection sheet for any bulk milk tank trucks under inspection.
-
Vehicle and Milk Tank Truck Properly Identified - It shall be the responsibility of the milk tank truck owner or operator to ensure the proper and legible identification of the milk tank truck(s) in their possession.
-
Previous Inspection Sheet or Affixed Label Available - When a milk tank truck transports milk and milk products from one (1) regulatory jurisdiction to another it is not necessary to inspect each milk tank truck upon each arrival. Milk tank truck owners and operators shall carry proof of annual inspection from a recognized regulatory agency. A milk tank truck may be inspected at any time or at the discretion of any regulatory agency responsible for the milk supply.
-
Sample Chain-of-Custody - When samples for official laboratory analysis are transported by any individual where the sample chain-of-custody must be established, the driver may be required to carry a valid permit or shall be evaluated biennially for the collection of samples for official laboratory analysis. The criteria from Section I, Evaluation of Bulk Milk Hauler or Sampler Procedures, Item 7, Sampling Responsibilities of this appendix shall be used as the basis for the evaluation. As an alternative, a sample case sealed as required by the regulatory agency may be accepted.
History
- Author: G. M. Gallaspy, Jr.
- Authority: Code of Ala. 1975, §§22-2-2, 22-20-7.
- Repealed and New Rule: Filed October 18, 2018; effective December 2, 2018.
Ala. Admin. Code r. 420-3-16-AC Appendix C - Dairy Farm Construction Standards and Milk Production
(I) TOILET AND SEWAGE DISPOSAL FACILITIES FLUSH TOILETS
(a) Flush toilets are preferable to pit privies, earth closets, or chemical toilets at both dairy farms and milk plants. Their installation shall conform to the applicable state plumbing regulations. Toilets shall be located in a well-lighted and well-ventilated room. Fixtures shall be protected against freezing. The following shall be considered defects in flush-toilet installations:
-
Insufficient water pressure or volume.
-
Leaky plumbing.
-
Clogged sewers, as evidenced by overflowing toilet bowl.
-
Broken tile lines or clogged disposal field.
-
Access of dairy lactating animals to the effluent below the sewer or disposal-field discharge.
-
Effluent coming to the surface of the ground in the absorption field.
-
Toilet room floor soaked with urine or other discharges.
-
Offensive odors or other evidence of lack of cleanliness.
-
Location of soil lines, septic tank, absorption field, or leaching pit closer to the source of water supply than the limits indicated in Appendix D.
(II) SEPTIC TANKS
(a) Disposal of the wastes from toilets should preferably be into a sanitary-sewer system. Where such systems are not available to a dairy farm or milk plant, the minimum satisfactory method should include treatment in a septic tank, with the effluent discharged into the soil. Where soil of satisfactory permeability is not available, the effluent shall be disposed of in accordance with the rules of the applicable government authority. It is preferable to treat floor drainage, wastes from washing of utensils, etc., in separate systems. When such wastes are combined with toilet wastes in the septic tank system, careful consideration shall be given to the expected flow in the design of both the septic tank and the leaching system.
(b) The septic tank shall be located a safe distance from water sources as determined by consideration of the criteria indicated in Appendix D and must meet all of the requirements of 420-3-1 Alabama Department of Public Health Onsite Sewage Treatment and Disposal.
(III) GUIDELINE #45 - GRAVITY FLOW GUTTERS FOR MANURE REMOVAL IN MILKING BARNS - Published by the Dairy Practices Council
(a) The gravity flow gutter concept for manure removal comes from Europe. Manure falls into a deep gutter in the barn floor and then flows by gravity to a cross channel or outlet pipe to storage. A low 8-20 centimeters (3)"- (8)" dam retains a lubricating liquid layer over which the manure flows (Fig. 1). After one (1) to three (3) weeks in a newly started gutter, the manure surface forms an incline of 1 percent to 3 percent above the dam. Then the manure moves continuously over the lip. The gutter shall be deep enough to contain manure sloped at this shallow angle.
Figure 1. Side Cross Section of a Gravity Flow Gutter
Figure 2. Stepped Gravity Flow Gutter
Figure 3. Cross Section of a Typical Gutter and Grate
(b) Because manure moves by its own weight, no mechanical equipment is required to remove it from the barn. Generally the cost of the gutter and cover grates is less than the cost of installing, operating, and maintaining a mechanical cleaner.
(c) This system is neither a flush gutter, where 115-225 liters (30-60 gallons) of water per cow is needed to remove manure from the gutter, nor is it an under-barn storage that is open to the barn. Rather, it is a conveying channel that carries the manure from behind the cow to the outside storage. The top surface of the slurry has been recorded to move 3 meters (10 feet) per hour.
(IV) CONSTRUCTION
(a) Gutter Depth - Gutter depth depends on the length of the gutter and the angle of incline of the manure surface. Design in this guideline assumes the manure surface forms a 3 percent slope. Most diets form wetter manure, and with no bedding the slope may be 1 percent less. The bottom should be level so the dam will hold a uniform liquid layer. The maximum depth of the gutter at the end opposite the discharge shall not exceed 138 centimeters (54 inches). In addition, the outlet shall be clear of obstructions.
(b) The depth includes an allowance for a 15 centimeters (6 inches) dam and 8 centimeters (3 inches) deep grates.
(c) Adding steps may decrease the maximum manure depth. The depth from the bottom of each dam to the bottom of the next level varies depending on the distance between steps (refer to Figure 2).
| TABLE 6 | | | | | | --- | --- | --- | --- | --- | | Slot Size vs. Cattle Age | | | | | | Age (Months) | 1-6 | 6-12 | 12-24 | Over 24 | | Slot Size (Inches) | 1-1 1/8 | 1 1/8 - 1 3/8 | 1 3/8 - 1 5/8 | 1 1/2 - 1 5/8 |
(d) Width of Gutters - The bottom of the gutter shall not exceed ninety-one 91 centimeters (thirty-six [36] inches) in width. A seventy-six (76) centimeters (thirty [30] inches) wide gutter is recommended. The gutter opening may be narrowed to fifty (50)- sixty (60) centimeters (twenty [20] to twenty-four [24] inches) in order to reduce the size and costs of grates.
Overflow Dam - The dam retains a lubricating liquid layer over the channel, which is essential to maintain flow. Typical heights range between eight (8) and twenty (20) centimeters (three [3] and eight [8] inches). Dams, if removable, would facilitate total cleanout, when and if necessary. Concrete, a steel plate, or a plank may be used to construct the dam. Caulking may be needed to seal the dam.
TABLE 7
| GRAVITY FLOW GUTTER DEPTH VS. LENGTH FOR MANURE FROM LACTATING ANIMALS | | | | | --- | --- | --- | --- | | Length | Depth | | | | Meters | Feet | Cm. | Inches | | 12 | 40 | 58 | 12 | | 18 | 60 | 78 | 18 | | 24 | 80 | 96 | 24 | | 30 | 100 | 114 | 30 | | 36 | 120 | 132 | 36 |
- Length - A 70 meter (226 feet) long gutter has worked, but typical distances between dams range from 12 to 24 meters (40 to 80 feet). Longer channels must be deeper; hence, they may cost more because they require more concrete and stronger forms.
TABLE 8
| GRAVITY FLOW GUTTER DEPTH VS. LENGTH FOR MANURE FROM LACTATING ANIMALS | | | | --- | --- | --- | | Step Height | | | | Length Between Dams | For 1.5% Manure Incline | For 3% Manure Incline | | 40' | 7" | 14" | | 50' | 9" | 18" | | 60' | 11" | 22" | | 70' | 13" | 25" | | 80' | 15" | 20" |
-
Grates - Commercial steel grates for stall barns and concrete slats for freestall barns are generally available. Table 7 suggests slot widths. Grates for stall barns are made from round or flat steel stock.
-
Cross Channel - The cross channel may be constructed like the gutter. At least a 60 centimeters (2 feet) drop from the top of the dam to the bottom of the cross channel is suggested to prevent backup of manure into it. The channel may be extended directly to storage. The slurry should enter the bottom; to prevent storage gases and cold air from returning up the channel. Channel depth, below grade, should be sufficient to prevent freezing.
Gravity flow via a concrete, steel, or plastic pipe may also be used to transfer manure to the bottom of the outside storage. Pipe as small as 38 centimeters (15 inches) diameter has been used successfully; however, 60 centimeters (24 inches) diameter pipe is recommended.
Do not empty channels into large sumps or pits within, or having direct openings into the barn. These storages will produce gas and odors that will be drawn into the barn through the ventilation systems.
Figure 4. Manure Transfer to Storage
MANAGEMENT
-
Flooding of Gutters - Prior to stocking the building, fill the gutters with 8 to 15 centimeters (3 to 6 inches) of water to start the lubrication layer.
-
Bedding Usage - The type and amount of bedding used is important to successful operation. Up to .5 kilograms (1 pound) per lactating animal per day of sawdust, fine cut shavings or peanut hulls still allows the system to work. Some have worked with long straw bedding, but it is not recommended. More bedding or long straw increases manure stiffness and may clog the gutter. Lactating animal mats allow minimum bedding use. Sometimes water may need to be added, depending upon the feed ration and amount of bedding used.
-
Wastage and Deposits - Keep feed and hay out of the gutter. Barn lime and soil brought in from outside may settle to the bottom. For this reason, the overflow dam on some gutters is removable for clean out. Buildup of solids has not been a problem under normal management, although the gutter will need cleaning if it has not been used for some time. Watch for islands of solids, especially where excess bedding or feed builds up. Cut these islands free of the walls to keep them flowing.
-
Cleaning Grates - Grates need cleaning at least weekly and, preferably, daily. A broom connected to a hose makes the job easy.
-
Flies and Odors - Flies have caused little or no problems. Biodegradable oil such as mineral oil may be sprayed on the manure surface to control them. Little or no odors have been observed in barns with good ventilation. There is no need to install fans to ventilate the gutters.
IV. CONVALESCENT (MATERNITY) PENS IN MILKING BARNS AND STABLES
While the requirement for concrete floors in milking barns and stables is necessary for good sanitation, climatic conditions in some areas of the country has created a need for convalescent (maternity) pens to be located in milking barns and stables. Therefore, convalescent pens may be allowed in the milk barn or stable; provided that the following requirements are met:
-
All floors in the production milking facility, with the exception of the convalescent pens, shall be of an impervious surface, with slopes for drainage as currently listed in the regulations.
-
Milk from animals milked in convalescent pens with non-impervious floors shall not enter the distribution system or be sold.
-
Routine milking in pens shall not be allowed.
-
Pens shall be located in a location so as not to contaminate milk holding transfer facilities or water supplies. Convalescent pens cannot be within 15 meters (50 feet) of a well.
-
A minimum of a 15 centimeters (6 inches) curb shall be provided on all exposed sides of the pen(s).
-
Convalescent pens shall be well bedded, clean, and dry at all times.
-
No water faucet or drinking fountain shall be located within the curbed area.
-
State sanitarians, at their discretion, may require cleaning and/or reconstruction of such pens, based at intervals as necessary when the pens present a sanitation problem.
-
It is recommended that the number of pens be limited to 1 per 50 lactating animals.
Figure 5. Side Cross Section of a Convalescent Pen
VI. GUIDELINES FOR CONVENTIONAL STALL BARN WITH GUTTER GRATES OVER LIQUID MANURE STORAGE
INTRODUCTION
The use of liquid manure storage under milking barns can be a cost, labor, and energy efficient method for handling dairy animal wastes. This type of system can aid in pollution control and will provide a safe and healthy environment for cattle and humans under the following guidelines:
-
Plans for the construction of a conventional stall barn, with gutter grates over liquid manure storage, shall be submitted to the Health Officer for approval before work is begun. Upon completion of the work, the builder shall furnish the purchaser with a signed written statement certifying that the system is constructed so as to be in full compliance with these guidelines.
-
The storage capacity of the liquid manure tank shall be for a minimum of nine (9) months.
-
A negative pressure mechanical ventilation system shall be installed to meet the following requirements (refer to Figures 6 and 7):
a. Provide a maximum exhaust capacity of 40 air changes per hour from the occupied area. Of this total, about one-half, 20 air changes per hour shall be considered the cold weather part of the system and shall be exhausted through the manure storage area. The remaining 20 air changes per hour shall be considered the warm weather part of the system and shall be exhausted through the barn walls.
b. Of the 20 air changes exhausted through the manure storage area there shall be a minimum continuous exhaust of 4 air changes per hour. The additional cold weather capacity of about 16 air changes per hour shall be thermostatically controlled. All fans exhausting from the manure storage area shall be installed in permanent fan houses built on the exterior wall of the barn and connected directly to the manure storage area. These fans shall be single-speed with a certified delivery rating against 6 millimeters (0.25 of an inch) water gauge static pressure. One (1) pit fan shall operate continuously. Airflow shall be from the occupied area through the gutters. The use of variable-speed fans is prohibited.
c. Fans supplying the additional summer capacity shall be mounted to discharge directly through the barn walls. They may be mounted on the outside of the building and the openings closed with insulated panels in cold weather, or when mounted in the walls be protected with an inside insulated cover to eliminate condensation and frost formation on the shutters and mountings. Warm weather fans are to be located on the same side of the barn as the pit fans. They must have a certified delivery rating against 3 millimeters (0.125 of an inch) water gauge static pressure and should be single speed.
d. All fans, except those providing the minimum continuous exhaust rate are to be controlled by thermostats located away from the barn walls. All pit fans are to be in operation before any of the wall fans are started. An electrical thermal overload device of the proper size shall protect each fan.
e. Calculation Method: To calculate the fan capacity in cubic feet per minute (cfm) for a particular barn, multiply the length times the width times the average ceiling height, all in feet, to obtain the volume. Divide the volume by 15 to obtain the minimum continuous capacity of 4 air changes per hour in cfm.
W × L × H15=cfm
For Example: Barn width 36 feet, length 160 feet and average ceiling height eight (8) feet-(6) inches. This would be a reasonable size for 60 stalls and 2 pens. The calculation of the minimum continuous exhaust for this example would be:
36 × 160 × 8.515=3,264 cfm
Total cold weather capacity of 20 air changes per hour equals 5 times the minimum capacity: 3,264 x 5 = 16,320 cfm.
Use 2 fans of 3,264 each and 2 fans of 4,896 cfm each to make up the total. Build (2) fan houses. Mount one 3,264 cfm and one 4,896 cfm fan in each. Operate one 3,264 cfm fan continuously. Thermostatically control the second 3,264 cfm fan at 4.5°C (40°F). Control the two (2) larger fans with thermostats set at 6°C (43°F) and 8°C (46°F). Divide the summer capacity of an additional 20 air changes per hour among three (3) fans of 5,440 cfm each. Locate these fans in the walls. Control them with thermostats set to 10°C–13°C (50°F–56°F (refer to Figure 6 for the approximate locations for all fans). Fans of the exact calculated capacity are usually unavailable. Always select those having a slightly higher rather than lower capacity.
f. Adequate incoming fresh air, to enable the fan exhaust system to function as designed, shall be provided. A continuous slot inlet with manual adjustment on 1 side is recommended to provide uniform fresh air distribution throughout the barn (refer to Figure 7). Adjustment of the slot opening opposite the fans is to be done manually for cold and warm weather conditions. Careful construction of the fresh air intake system is essential to the satisfactory performance of the ventilation system.
-
A stand-by generator to supply electric current to the ventilation system, in the event of a power failure, shall be provided.
-
Construction Requirements
a. The floor system over the pit shall be designed to safely support all animal weight, plus the possibility of a tractor that may be needed to remove a sick or dead animal. Agitating and pumping of the stored manure shall be done through annexes built outside the barn (refer to Figures 6 and 7). Service alley floor and lactating animal stall platforms shall be constructed to drain to the grated gutter tank opening, located between the lactating animal stall and the service alley.
b. Waste water from the milkhouse can be discharged into the pit. Sanitary (toilet) waste shall not be disposed of in the manure storage tank. When wastewater from the milkhouse is discharged into the pit, a drop pipe shall be connected to the discharge line so that the liquid waste will be deposited beneath the surface of the tank contents to prevent turbulence and possible odor production.
c. Grates over the gutters, tank slot openings, shall be of sufficient strength to support all applied loads. A suitable grate design is one using 16 millimeters (0.625 of an inch) smooth steel bars running the length of the open gutter. The distance between the center of the first bar and the vertical face of the stall platform should be 57 millimeters (2.25 inches). The remaining bars should be spaced 63 millimeters (2.5 inches) center-to-center. Support bars crossing the gutters should be 19 millimeters (0.75 of an inch) diameter and spaced 40 centimeters (16 inches) center-to-center.
-
Little or no bedding can be used with this system, rubber mats or equivalent, and lactating animal trainers shall be installed at the time the barn is constructed. Daily cleaning of grates with a stiff broom or scraper is recommended.
-
Other construction criteria and management practices recommended for stall dairy barns should be followed.
-
Requirements for emptying holding tanks:
a. Remove all animals and post signs on all doors that no one is to enter the milking barn during the time the tank is being agitated.
b. All pit fans shall be operating during agitation and emptying.
c. All milkhouse and feed storage area openings, doors, windows, etc., shall be closed.
The milking barn shall remain evacuated by animals. and people for at least one (1) hour, after agitation of the holding tank is completed.
Figure 6. Schematic Diagram Showing Suggested Exhaust Fan Locations for a Typical Stall Dairy Barn with Gutter Grates Over Liquid Manure Storage
Figure 7. Schematic Diagram Showing General Pattern of Ventilation Air Movement, Slot Inlet Design and Fan House for Pit Fans
I. DAIRY - CONSTRUCTION AND OPERATION - MILKING BARN, STABLE OR PARLOR
Numerous factors, including the size and topography of the farm, the availability of utilities, the condition and disposition of existing buildings, the dairy operator's ultimate goals for the enterprise, and the operator's construction budget serve to make each milk producer's herd housing problems individual and unique.
While there has been a tendency for workers to develop strong convictions about the practicability of given housing or milking systems, there is little doubt that the success or failure of most dairy farm operations may be traced to good or poor planning. When the unique problems of each system in its individual applications are given proper consideration, the job of producing clean milk is made easier and compliance with regulations is simplified. For example, operators of barns in which lactating animals are housed and milked will find that efficient ventilation not only reduces condensation but also relieves the problem of dust and mold on walls, ceilings, and windows. When window sills are sloped or windows set flush with interior walls in stanchion barns, the accumulation of dust and unwanted miscellaneous items is similarly lessened. Covered recessed light fixtures remain clean longer and are less subject to damage than those projecting from the ceiling.
Operators of milking parlor loose-housing systems, on the other hand, will value design features such as mechanically operated doors, which speed up animal traffic, and glazed wall finishes, which cut down the time required for proper post-milking wash-up of the parlor. Cleaner lactating animals result from proper planning and management of exercise yards and bedded areas. At least 9 square meters (100 square feet) of surfaced yard and not less than 5 square meters (50 square feet) of bedded space are recommended for each animal to be accommodated. Provisions shall also be made for the removal at least daily of manure from exercise yards and traffic lanes. Operators utilizing loose housing have shown considerable interest in free-stall housing. Many workers have concluded that it provides the solution to the problems of unclean lactating animals and excessive bedding demands that have plagued loose housing in past years. Milk producers planning new construction or large-scale changes in existing housing should carefully study its features.
Adequate light shall be available in all work areas in the milking barn, stable or parlor. Because many dairy functions are frequently performed after dark, it is important that the required minimum of 10 foot-candles (110 lux) of illumination be available from artificial sources. While absolute certainty of compliance with this requirement can only be confirmed by the use of a light meter, experience has shown that milking barns which otherwise meet the standards of these Rules will be properly lighted when equipped with one 100-watt bulb (or its fluorescent equal) for each 3 stanchions or per 3 meters (10 linear feet) of walkway behind each row of lactating animals in face-in barns or between rows of lactating animals in face-out barns. In addition, a smaller number of bulbs, equally spaced, are recommended for feed alleys in front of the lactating animals. When natural light is utilized, a minimum of .37 square meters (4 square feet) of window space for each 5.6 square meters (60 square feet) of floor space is recommended.
Construction plans and suggestions for the various systems of animal management are available to the sanitarian and the dairyman from numerous sources, including the USDA, the county extension agent, farm periodicals, and the trade associations serving the building supply industry.
MILKHOUSE
Milkhouses should be large enough to provide adequate space to meet present needs and should take into account the prospect of future expansion. Installed milkhouse equipment should be readily accessible to the operator. Aisles should be at least 76 centimeters (30 inches wide), with added allowance at the outlets of bulk milk tanks, adjacent to wash-and-rinse vats and where operational conditions warrant. It is especially important that the space available to bulk milk tanks and mechanical cleaning systems be adequate to permit their disassembly, inspection, and servicing.
Floor drains should not be located under bulk milk tanks unless there is sufficient room for servicing. Floor drains should not be located directly under the outlet of a bulk milk tank. Drains and waste disposal systems should be adequate to drain the volume of water used in rinsing and cleaning.
Milkhouses should be well ventilated. Proper ventilation not only avoids the obvious disadvantages of condensation on equipment and walls, it also lengthens the useful life of the building and its equipment. The constant need for renewal of painted surfaces, the repair of wooden fixtures and frames, and the removal of algae and mold from walls and ceilings of poorly ventilated milkhouses can represent a continuing expense to the operator.
Where possible, windows should be placed to provide cross ventilation. In addition, one (1) or more ceiling vents should be located to receive water vaporizing from wash-and-rinse vats and other sources of evaporative moisture.
Glass brick is sometimes substituted for windows in milkhouse construction. In these instances, mechanical ventilation shall be provided. A system affording filtered positive air pressure is recommended over exhaust ventilation, as the latter frequently draws dust, insects, and odors into the milkhouse.
The great demand for water under pressure in milkhouse operations has emphasized the importance of protecting plumbing from freezing. Devices that have proved effective include the insulation of water lines, the use of wrap-around heat tape, infrared lamps, and thermostatically controlled space heaters.
Insulated milkhouses make protection against freezing easier and more economical, and offer the additional advantage of greater comfort for the operator. The factor of personal convenience frequently results in better performance by the operator, with subsequent benefits to milk quality. Automated milking and mechanical cleaning systems of milking equipment has increased the use of hot water in the milkhouse. The following table indicates the volumes of water required to fill 30 meters 100 feet of pipeline of varying diameters:
TABLE 9
| WORK WATER VOLUME OF VARIOUS SIZED PIPELINES | | | --- | --- | | Length Between Dams | For 1.5% Manure Incline | | 1 | 4.7 | | 1.5 | 9.2 | | 2 | 16.3 |
Since most cleaning installations employ a pre-rinse, followed by wash-and-rinse cycles, this table actually represents only one-third (⅓) the usual milking-time demand for heated water. Also, it does not include the "take up" of collecting jars, pumps, rubber parts, etc. Udder washing, bulk milk tank cleaning, and similar milkhouse tasks offer additional uses for hot water.
Sanitarians should compute the hot water demand of the individual milking systems under their supervision and require that not less than the minimum amount be available at all times. Milk producers should be made aware of the fact that effective cleaning of mechanically cleaned installations is impossible without adequate hot water and should be encouraged to provide a supply which exceeds their expected need. Such planning avoids emergency shortages and allows for normal expansion of the herd and facilities.
Detailed plans for milkhouses, as well as recommendations on hot water needs, insulation, lighting, and ventilation are available from power companies, building supply associations, county agricultural extension agents, and state universities.
Refrigeration, electrical, or mechanical systems powered by gasoline or diesel engines has no place in a milkhouse, milking barn, or in any communicating passageway between the milkhouse and milking barn. Such equipment is characteristically given to oil leakage and the discharge of fumes. The space occupied by it is difficult to keep clean and frequently becomes a gathering place for trash and flammable materials. With effective planning, these engines and their accessory equipment can be located, without detriment to their performance, in a separate room or building adjacent to the barn or milkhouse.
MILKING METHODS
Milking methods shall be geared to permit the efficient withdrawal of milk without introducing undue numbers of bacteria or causing injury to the udder.
The goal of a successful milking procedure is to ensure that most dairy animals will be milked quickly, gently, and completely under conditions that optimize udder health and result in the production of milk with a low bacteria count and somatic cell count.
3-A Accepted Practices for the Design, Fabrication, and Installation of Milking and Milk Handling Equipment, Number 606-##, provides guidance on performance and information requirements and certain dimensional requirements for satisfactory functioning of milking equipment for milking and cleaning. Methods for milking equipment testing to ensure compliance with this Accepted Practice are presented in the NMC guidelines Procedures for Evaluating Vacuum Levels and Air Flow in Milking Systems.
Suggested milking procedures to minimize the risk of mastitis and to enhance the quality of milk are presented in the NMC publication Current Concepts of Bovine Mastitis and the NMC factsheet Recommended Milking Procedures.
It has been known for many years that a relationship exists between mastitis and milking practices. While not all the facts are known about mastitis, it is abundantly clear that its control is enhanced by use of mechanically sound milking equipment and good milking practices. The NMC has described a satisfactory milking system as one which:
-
Maintains a stable vacuum in the teat cup and at a level adequate for completely milking most udders in three (3) to five (5) minutes.
-
Does not stress the tissues of the teat by excessive stretching and ballooning.
-
Produces massage without harsh action.
-
Is designed so that the entire system can be sanitized efficiently and satisfactorily. The NMC considers proper milking procedure to include the following:
(i) Before the milking unit is applied to the udder, the operator takes thirty (30) seconds to prepare the lactating animal in the recommended manner to obtain milk letdown, and the milking machine should be applied immediately thereafter.
(ii) The teat cups are attached in a manner to limit the volume of air drawn into the system.
(iii) The teat cups are positioned as low on the teats as practicable.
(iv) The operator stays near the machine and, at the end point of milk removal, the claw is briefly pulled down to open the teat cavity and remove the strippings. Stripping by machine should not extend over a period of more than fifteen to twenty (15-20) seconds. Prolonging stripping can be injurious to the udder.
(v) Before removing the machine, the vacuum to the teat cups is broken and the cups removed in a gentle manner.
REVERSE FLUSH SYSTEMS
Systems are acceptable if they are designed, installed, and operated in accordance with the following parameters for reverse flush systems:
-
All product-contact surfaces shall conform to the construction criteria of 420-3-16-.09(09).
-
An intervening break to the atmosphere shall be provided between the water and/or chemical solution and the milk and/or milk product-contact surfaces at all times.
-
If a pre-rinse cycle is used it shall be with safe water.
-
The system shall provide for:
(a) A chemical solution cycle with a chemical solution complying with the provisions of Appendix F of these rules.
(b) The chemical solution strength shall be limited to that strength necessary to accomplish its intended effect and shall not leave a significant residual in the milk.
(c) A post-rinse cycle with safe water. The use of treated water to prevent psychrophilic microorganism contamination should be considered.
(d) A drain cycle with sufficient time to drain or remove all moisture from the product-contact surfaces of the reverse flush system.
- When air under pressure is used in contact with product or solution-contact surfaces, it shall comply with the requirements for air under pressure contained in 420-3-16-.09(16), provided that an exception to the piping requirement for the air piping downstream from the terminal filter may be granted when:
(a) The piping is used only for filtered air.
(b) At least one (1) access point is available to determine cleanliness of the air piping.
(c) The piping is of a smooth, non-absorbent, corrosion-resistant, non-toxic material, including any adhesives used in joints.
In some installations, a check-valve may be required to prevent water and/or chemical solution from entering these air lines.
DRUG RESIDUE AVOIDANCE CONTROL MEASURES
Animal identification and record keeping are critical for avoiding milk drug residues. Producers should establish systems to ensure that animal drugs are used properly and be able to provide evidence that adequate control over the administration of drugs to prevent residues in milk and/or meat has been implemented. These control systems should accomplish the following objectives:
- Lactating animals treated with medicinal agents are:
(a) Identified, i.e., leg bands, chalk marks, etc.; and/or
(b) Segregated; or
(c) Other means provided to preclude the adulteration of milk offered for sale.
- Treatment Records include the following information:
(a) Identity of the animal(s) treated.
(b) Date(s) of treatment.
(c) Drug(s) or other chemicals administered.
(d) Dosage administered
(e) Milk discard time.
(f) Withdrawal time prior to slaughter, even if zero.
Note: Records may consist of paper and file folders, card files, appointment book-type calendars, monthly paper calendars, chalk boards (temporary records), electronic computer records, etc.
-
Maintenance of Records - The proper use or misuse of some animal drugs may cause prolonged residues in milk 4 to 45 days and meat 18 to 24 months. Verification of drug treatment records may be necessary in the event of an investigation or trace back by the industry or Health Officer to identify specific treated animal(s) that may be related to a milk or dairy beef residue. Producers should maintain all treatment records for a minimum of two (2) years in the event of a need to trace back or follow up on a confirmed milk or meat residue.
-
Quarantine/segregation of treated animals or other means to preclude the sale of milk or offering of treated animals for sale for slaughter prior to the end of the prescribed withdrawal time.
-
Education of all farm personnel involved in treating animals on proper drug use and methods to avoid marketing adulterated milk or meat for human food.
INSECT AND RODENT CONTROL
The complete elimination of flies from the farm premises is practically unattainable. However, a major reduction of fly infestation is obtainable by the dairy farm operator who conscientiously follows a sustained program of sanitation, screening, and the proper use of insecticides.
The milk producer or milk plant operator must be continually aware of the potential hazard to people and animals which is inherent in most pesticides, including insecticides and rodenticides. It is important that they employ only those insecticides and rodenticides that are recommended by competent authority for the insect and rodent problems they seek to overcome, and that they follow implicitly the manufacturer's label directions for their use. Questions on the use of pesticides should be referred to the appropriate Health Officer and/or County Agricultural Extension Agent.
Intermittent, time release, high-pressure insect fogging or spraying systems shall be installed and operated in accordance with the following guidelines:
-
The insecticide shall be registered with the EPA.
-
The label on the insecticide container shall specify that the insecticide may be used on dairy farms and in milking areas.
-
The label shall contain adequate instructions for the safe use of the insecticide.
-
The insecticide shall be designated for use in an intermittent, time release, high-pressure insect fogging system and used in accordance with the labeling directions.
-
The container, tank, or barrel of concentrated insecticide or use solution and the pumping or pressurizing equipment shall not be located in the milkhouse.
-
Nozzles, which would emit, spray, or fog the insecticide shall not be located in the milkhouse.
-
Nozzles shall be located, positioned, and operated so that they will not spray, fog, drip, or drain any insecticide on milk pipeline and return solution line openings, milking machine appurtenances, including milk claws, inflations, flow sensors, and interconnecting flexible milk tubing, milk receivers, or releasers, milk pumps, weigh jars, milk measuring equipment, or over any area where milk is poured, strained, or transferred.
-
Nozzles shall be located, positioned, and operated so that they will not contaminate any feed or water.
-
The fogging or spraying systems, which have nozzles located in the milking barn or parlor, shall not be operated during milking. In addition, the system shall not operate during the washing and sanitizing of milking equipment in a milking barn or parlor. This may be accomplished by inter-wiring the system so that it will not operate when the vacuum pump is operating or by a master cut-off switch with a conspicuously posted sign warning the operator that the switch shall be turned off while milking, cleaning, and sanitizing.
-
The fogging or spraying system shall operate so that only the amount of insecticide necessary to accomplish the intended purpose of reducing fly and other insect populations is used. Excessive insecticide which leaves a film on exposed walls, floors, and equipment, should be considered a violation of Item 19r of these rules.
-
These systems should be considered an adjunct to and not a replacement for good sanitary practices of proper manure removal and disposal to adequately control fly and other insect breeding on dairy farms.
Effective rodent control, like insect control, is dependent on sanitation for much of its success. The careful elimination of trash and woodpiles; the rodent-proofing of feed bins, corn cribs, and similar structures; the prompt removal of spilled feed and manure to places of ultimate disposition; and the deliberate elimination of protected harborage areas in farm buildings, all tend to discourage rodents near the dairy farm. Such a program also pays excellent dividends in feed savings, lowered maintenance costs for farm buildings, reduced fire hazards, and lessened risk of disease outbreaks among farm animals.
Anticoagulant poisons, Warfarin, Fumarin, etc. have offered improved means of controlling rodents on the farm. Used according to directions, and with due precaution against their consumption by domestic animals, these chemicals should keep the rodent population in check while additional preventive programs are instituted.
REFERENCES
D. W. Bates, How to Plan Your Dairy Stall Barn, M-132 (Revised 1972) University of Minnesota.
Midwest Plan Service, Ames, Iowa, Plan No. 72327, Dairy Barn, 60 Tie Stalls, Gable Roof, Liquid Manure 1974.
D. W. Bates and J. F. Anderson, 1979. Calculation of Ventilation Needs for Confined Cattle, J. of the American Veterinary Medical Association, 1979.
Midwest Plan Service, Ames, Iowa, Dairy Housing and Equipment Handbook, 1985.
History
- Author: G. M. Gallaspy, Jr.
- Authority: Code of Ala. 1975, §§22-2-2, 22-20-7.
- Repealed and New Rule: Filed October 18, 2018; effective December 2, 2018.
Ala. Admin. Code r. 420-3-16-AD Appendix D - Standards for Water Sources
The Grade "A" Pasteurized Milk Ordinance, Revision 2015 (PMO), formal FDA interpretations of the PMO, and other written USPHS/FDA opinions shall be used in evaluating the acceptability of individual water supplies and water system construction requirements at dairy farms, milk plants, and single-service container manufacturing facilities.
The applicable Government Water Control Authority requirements, which are less stringent than the PMO, shall be superseded by the PMO. The applicable Alabama Water Control Authority (AWCA) requirements which are more strict than the PMO, shall not be considered in determining the acceptability of water supplies during ratings, check ratings, single-service listing evaluations, and audits. For example, the PMO requires a satisfactory farm water sample every three (3) years. If state law required such samples to be taken annually, a Sanitation Rating Officer (SRO) conducting a sanitation rating, which includes that farm, will give that farm full credit for water sample frequency, if the PMO three (3) year requirement is met, even though the state required annual frequency is not met.
Supplies other than individual water supplies, which have been approved as safe by the AWCA, shall be considered to be acceptable sources as provided in 420-3-16-.08 for Grade "A" inspections, as well as for all other IMS purposes without further inspection of the spring, well, or reservoir treatment facility(ies), testing records, etc.
I. LOCATION OF WATER SOURCES DISTANCE FROM SOURCES OF CONTAMINATION
All ground water sources should be located a safe distance from sources of contamination. In cases where sources are severely limited; however, a ground water aquifer that might become contaminated may be considered for a water supply, if treatment is provided. After a decision has been made to locate a water source in an area, it is necessary to determine the distance the source should be placed from the origin of contamination and the direction of water movement. A determination of a safe distance is based on specific local factors described in the following section on sanitary survey.
Because many factors affect the determination of "safe" distances between ground water supplies and sources of pollution, it is impractical to set fixed distances. Where insufficient information is available to determine the "safe" distance, the distance should be the maximum that economics, land ownership, geology, and topography will permit. It should be noted that the direction of ground water flow does not always follow the slope of the land surface. A person with sufficient training and experience to evaluate all of the factors involved should inspect each installation.
Since the safety of a ground water source depends primarily on considerations of good well construction and geology, these factors should be the guides in determining safe distances for different situations. The following criteria apply only to properly constructed wells, as described in this appendix. There is no safe distance for a poorly constructed well.
When a properly constructed well penetrates an unconsolidated formation, with good filtering properties, and when the aquifer itself is separated from sources of contamination by similar materials, research and experience have demonstrated that fifteen 15 meters (fifty [50] feet) is an adequate distance separating the two. Lesser distances should be accepted only after a comprehensive sanitary survey conducted by qualified applicable AWCA Officials has determined such lesser distances are both necessary and safe.
If it is proposed to install a properly constructed well in formations of unknown character, the state or U.S. Geological Survey and the state or local health agency should be consulted.
When wells must be constructed in consolidated formations, extra care should always be taken in the location of the well and in setting "safe" distances, since pollutants have been known to travel great distances in such formations. The owner should request assistance from the applicable state or local health agency.
The following table is offered as a guide in determining acceptable distances of a well from sources of contamination:
TABLE 10
| DISTANCE OF A WELL FROM SOURCES OF CONTAMINATION | | | | --- | --- | --- | | Formation | Minimum acceptable distance of a well from sources of contamination | | | Favorable (Unconsolidated) | 15 meters (50 feet) – Lesser distances only on applicable government agency approval following a comprehensive sanitary survey of the proposed site and immediate surroundings. | | | Unknown | 15 meters (50 feet) – Only after a comprehensive geological survey of the site and its surroundings has established, to the satisfaction of the applicable government agency that favorable formations do exist. | | | Poor (Consolidated) | Safe distances can be established only following both the comprehensive geological and comprehensive sanitary surveys. These surveys also permit determining the direction in which a well may be located with respect to sources of contamination. In no case should the acceptable distance be less than 15 meters (50 feet). | |
EVALUATING CONTAMINATION THREATS TO WELLS
Conditions unfavorable to the control of contamination and that may require specifying greater distances between a well and sources of contamination are:
-
Nature of the Contaminant: Human and animal excreta and toxic chemical wastes are serious health hazards. Salts, detergents, and other substances that dissolve in water can mix with ground water and travel with it. They are not ordinarily removed by natural filtration.
-
Deeper Disposal: Cesspools, dry wells, disposal, and waste injection wells and deep leaching pits that reach aquifers or reduce the amount of filtering earth materials between the wastes and the aquifer increase the danger of contamination.
-
Limited Filtration: When earth materials surrounding the well and overlying the aquifer are too coarse to provide effective filtration, as in limestone, coarse gravel, etc., or when they form a layer too thin, the risk of contamination is increased.
-
The Aquifer: When the materials of the aquifer itself are too coarse to provide good filtration, as in limestone, fractured rock, etc., contaminants entering the aquifer through outcrops or excavations may travel great distances. It is especially important in such cases to know the direction of ground water flow and whether there are outcrops of the formation, or excavations reaching it, "upstream" and close enough to be a threat.
-
Volume of Waste Discharged: Since greater volumes of wastes discharged and reaching an aquifer can significantly change the slope of the water table and the direction of ground water flow, it is obvious that heavier discharges can increase the threat of contamination.
-
Contact Surface: When pits and channels are designed and constructed to increase the rate of absorption, as in septic tank leaching systems, cesspools, and leaching pits, more separation from the water source will be needed than when tight sewer lines or waste pipes are used.
-
Concentration of Contamination Sources: The existence of more than one source of contamination, contributing to the general area, increases the total pollution load and, consequently, the danger of contamination.
SANITARY SURVEY
The importance of a sanitary survey of water sources cannot be overemphasized. With a new supply, the sanitary survey should be made in conjunction with the collection of initial engineering data, covering the development of a given source and its capacity to meet existing and future needs. The sanitary survey should include the detection of all health hazards and the assessment of their present and future importance.
Persons trained and competent in public health engineering and the epidemiology of waterborne diseases should conduct the sanitary survey. In the case of an existing supply, the sanitary survey should be made at a frequency compatible with the control of the health hazards and the maintenance of a good sanitary quality. The information furnished by the sanitary survey is essential to complete the interpretation of bacteriological and frequently the chemical data. This information should always accompany the laboratory findings. The following outline covers the essential factors that should be investigated or considered in a sanitary survey. Not all of the Items are pertinent to any one (1) supply and, in some cases; items not in the list would be important additions to the survey list.
Ground Water Supplies
-
Character of local geology and slope of ground surface.
-
Nature of soil and underlying porous strata; whether clay, sand, gravel, rock (especially porous limestone); coarseness of sand or gravel; thickness of water-bearing stratum; and depth to water table and location; and log and construction details of local wells in use and abandoned.
-
Slope of water table, preferably determined from observational wells or as indicated, presumptively, but not certainly, by the slope of ground surface.
-
Extent of drainage area likely to contribute water to the supply.
-
Nature, distance, and direction of local sources of pollution.
-
Possibility of surface-drainage water entering the supply and of wells becoming flooded and methods of protection.
-
Methods used for protecting the supply against pollution by means of sewage treatment, waste disposal, and the like.
-
Well Construction
(a) Total depth of well.
(b) Casing: Diameter, wall thickness, material, and lengths from surface.
(c) Screen or Perforations: Diameter, material, construction, locations, and lengths.
(d) Formation Seal: Material, cement, sand, bentonite, etc.; depth intervals; annular thickness; and method of placement.
-
Protection of Well at Top: Presence of sanitary well seal, casing height above ground floor or flood level, protection of well vent, and protection of well from erosion and animals.
-
Pump-house Construction: Floors, drains, etc., capacity of pumps, and draw-down when pumps are in operation.
-
Availability of an Unsafe Supply: Usable in place of normal supply, hence involving danger to the public health.
-
Disinfection Equipment: Supervision, test kits, or other types of laboratory control.
Surface Water Supplies
-
Nature of Surface Geology: Character of soils and rocks.
-
Character of Vegetation: Forests, cultivated, and irrigated land, including salinity, effect on irrigation water, etc.
-
Population and sewered population per square mile of catchment area.
-
Methods of sewage disposal, whether by diversion from watershed or by treatment.
-
Character and efficiency of sewage-treatment works on watershed.
-
Proximity of sources of fecal pollution to intake of water supply.
-
Proximity, sources, and character of industrial wastes, oil field brines, acid mine waters, etc.
-
Adequacy of supply as to quantity.
-
For Lake or Reservoir Supplies: Wind direction and velocity data, drift of pollution, sunshine data, and algae.
-
Character and Quality of Raw Water: Coliform organisms (Most Probable Number [MPN]), algae, turbidity, color, and objectionable mineral constituents.
-
Nominal period of detention in reservoirs or storage basin.
-
Probable minimum time required for water to flow from sources of pollution to reservoir and through reservoir intake.
-
Shape of reservoir, with reference to possible currents of water, induced by wind or reservoir discharge, from inlet to water supply intake.
-
Protective measures in connection with the use of watershed to control fishing, boating, landing of airplanes, swimming, wading, ice cutting, and permitting animals on marginal shore areas and in or upon the water, etc.
-
Efficiency and constancy of policing.
-
Treatment of Water: Kind and adequacy of equipment, duplication of parts, effectiveness of treatment, adequacy of supervision and testing, contact period after disinfection, and free chlorine residuals carried.
-
Pumping Facilities: Pump-house, pump capacity, standby units, and storage facilities.
II. CONSTRUCTION SANITARY CONSTRUCTION OF WELLS
The penetration of a water-bearing formation by a well provides a direct route for possible contamination of the ground water. Although there are different types of wells and well construction, there are basic sanitary aspects that shall be considered and followed:
-
The annular space outside the casing shall be filled with a watertight cement grout or puddled clay from a point just below the frost line or deepest level of excavation near the well to as deep as necessary to prevent entry of contaminated water.
-
For artesian aquifers, the casing shall be sealed into the overlying impermeable formations so as to retain the artesian pressure.
-
When a water-bearing formation containing water of poor quality is penetrated, the formation shall be sealed off to prevent the infiltration of water into the well and aquifer.
-
A sanitary well seal, with an approved vent, shall be installed at the top of the well casing to prevent the entrance of contaminated water or other objectionable material.
Well Casing or Lining - All that part of the suction pipe or drop pipe of any well within three (3) meters (ten [10] feet) of and below the ground surface shall be surrounded by a watertight casing pipe extending above the ground, platform, or floor surface, as the case may be, and covered at the top as herein provided. The casing of every well shall terminate above the ground level; the annular space outside the casing shall be filled with a watertight cement grout or clay, with similar sealing properties, from the surface to a minimum of three (3) meters (ten [10] feet) below the ground surface. A dug well, in lieu of a casing pipe, may be provided with a substantial watertight lining of concrete, vitrified tile with outer concrete lining, or other suitable material. Such lining shall extend at least three (3) meters (ten [10] feet) below the surface and shall extend up to the well platform or pump room floor with a watertight connection. In such case, the platform or floor shall have a suitable sleeve pipe, surrounding the suction pipe or drop pipe, and projecting above as herein provided for a casing pipe.
Well Covers and Seals: Every well shall be provided with an overlapping, tight-fitting cover at the top of the casing or pipe sleeve to prevent contaminated water or other material from entering the well.
The sanitary well seal, in a well exposed to possible flooding, shall be either watertight or elevated at least .6 meters (2 feet) above the highest known flood level. When it is expected that a well seal may become flooded, it shall be watertight and equipped with a vent line, whose opening to the atmosphere, is at least .6 meters (2 feet) above the highest known flood level.
The seal in a well not exposed to possible flooding shall be either watertight, with an approved vent line, or self-draining, with an overlapping and downward flange. If the seal is of the self-draining should be either watertight or flanged upward and provided with overlapping, downward flanged covers.
Some pump and power units have closed bases that effectively seal the upper terminal of the well casing. When the unit is the open type, or when it is located at the side, as with some jet and suction pump type installations, it is especially important that a sanitary well seal be used. There are several acceptable designs consisting of an expandable neoprene gasket, compressed between two (2) steel plates. They are easily installed and removed for well servicing. Pump and water well suppliers normally stock sanitary well seals.
If the pump is not installed immediately after well drilling and placement of the casing, the top of the casing should be closed with a metal cap screwed or tack welded into place, or covered with a sanitary well seal. For large diameter wells, such as dug wells, it would be difficult to provide a sanitary well seal, consequently, a reinforced concrete slab overlapping the casing and sealed to it with a flexible seal and/or rubber gasket should be installed. The annular space outside the casing should first be filed with suitable grouting or sealing materials, i.e., cement, clay, or fine sand.
A well slab alone is not an effective sanitary defense, since it can be undermined by burrowing animals and insects, cracked from settlement or frost heave or broken by vehicles and vibrating machinery. The cement grout formation seal is far more effective. It is recognized however, that there are situations that call for a concrete slab or floor around the well casing to facilitate cleaning and improve appearance. When such a floor is necessary, it shall be placed only after the formation seal and the pitless installation have been inspected.
Well covers and pump platforms shall be elevated above the adjacent finished ground level. Pump room floors shall be constructed of reinforced, watertight concrete and carefully leveled or sloped away from the well, so that surface and wastewater cannot stand near the well. The minimum thickness of such a slab or floor shall be 10 centimeters (4 inches). Concrete slabs or floors shall be poured separately from the cement formation seal and when the threat of freezing exists, insulated from it and the well casing by a plastic or mastic coating or sleeve to prevent bonding of the concrete to either.
All water wells shall be readily accessible at the top for inspection, servicing, and testing. This requires that any structure over the well be easily removable to provide full, unobstructed access for well servicing equipment. The so-called "buried seal," with the well cover buried under several meters (yards) of earth, is unacceptable because:
-
It discourages periodic inspection and preventive maintenance.
-
It makes severe contamination during pump servicing and well-repair more likely.
-
Any well servicing is more expensive.
-
Excavation to expose the top of the well increases the risk of damage to the well, the cover, the vent, and the electrical connections.
Well Pits and Drainage - Because of the pollution hazards involved, the well head, well casing, pump, pumping machinery, valve connected with the suction pump, or exposed suction pipe shall not be permitted in any pit, room, or space extending below ground level, or in any room or space above the ground, which is walled-in or otherwise enclosed, so that it does not have free drainage by gravity to the surface of the ground. Provided, that a dug well properly constructed, lined, and covered, as herein prescribed, shall not be construed to be a pit. Provided further, that pumping equipment and appurtenances may be located in a residential basement, which is not subject to flooding. And provided further, that in the case of existing water supplies which otherwise comply with the applicable requirements of this appendix, pit installations may be accepted, under the following conditions, when permitted by the AWCA:
-
Pits shall be of watertight construction, with walls extending at least 15 centimeters (6 inches) above the established ground surface at all points.
-
Pits shall be provided with a watertight, concrete floor, sloping to a drain which discharges to the ground surface at a lower elevation than the pit, and preferably at least 9 meters (30 feet) from it; or if this should be impossible, to a watertight, concrete sump, in the pit, equipped with a sump-pump discharging to the ground surface, preferably at least nine 9 meters (30 feet) from the pit.
-
Pits shall be provided with a concrete base for pumps or pumping machinery, so that such units shall be located at least thirty 30 centimeters (12 inches) above the floor of the pit.
-
Pits shall be provided with a watertight housing or cover in all cases.
-
If inspection should reveal that these conditions are not being properly maintained, the supply shall be disapproved.
Note: The PMO permits the acceptance of pit installations on existing water supplies but prohibits the installation of well pits on new water supplies. For well pits, “existing water supplies,” are those which were in use by a producer at the time they applied for a Grade “A” permit. Therefore, pit installations which meet the above criteria would be acceptable. Change in construction and extensive alterations of an existing water supply that does not affect the physical structure of the well pit does not require elimination of the well pit.
Manholes: Manholes may be provided on dug wells, reservoirs, tanks, and other similar features of water supplies. A manhole, if installed, shall be provided with a curb, the top of which extends at least 10 centimeters (4 inches) above the slab and shall be equipped, where necessary for physical protection, with a locked or bolted overlapping watertight cover. The sides of which extend downward at least 5 centimeters (2 inches). The covers shall be kept closed at all times, except when it may be necessary to open the manhole.
Vent Opening - Any reservoir, well, tank or other structure containing water for the dairy water supply may be provided with vents, overflows, or water-level control gauges which shall be so constructed as to prevent the entrance of birds, insects, dust, rodents or contaminating material of any kind. Openings on vents shall be not less than 46 centimeters (18 inches) above the floor of a pump room, or above the roof or cover of a reservoir. Vent openings on other structures shall be at least 46 centimeters (18 inches) above the surface on which the vents are located. Vent openings shall be turned down and screened with corrosion-resistant screen of not less than 16 x 20 mesh. Overflow outlets shall discharge above and not less than 15 centimeters (6 inches) from a roof, roof drain, floor, and floor drain or over an open water-supplied fixture. The overflow outlet shall be covered by a corrosion-resistant screen of not less than 16 x 20 mesh and by (0.6 centimeters) (0.25 of an inch) hardware cloth, or shall terminate in a horizontal angle seat check-valve.
DEVELOPMENT OF SPRINGS
There are two (2) general requirements necessary in the development of a spring used as a source of domestic water:
-
Selection of a spring with adequate capacity to provide the required quantity and quality of water for its intended use throughout the year.
-
Protection of the sanitary quality of the spring. The measures taken to develop a spring shall be tailored to its geological conditions and sources.
The features of a spring encasement are the following:
-
An open-bottom, watertight basin intercepting the source which extends to bedrock or a system of collection pipes and a storage tank.
-
A cover that prevents the entrance of surface drainage or debris into the storage tank.
-
Provisions for the cleanout and emptying of the tank contents.
-
Provision for overflow.
-
A connection to the distribution system or auxiliary supply (refer to Figure 17).
A tank is usually constructed in place with reinforced concrete of such dimensions as to enclose or intercept as much of the spring as possible. When a spring is located on a hillside, the downhill wall and sides are extended to bedrock or to a depth that will ensure maintenance of an adequate water level in the tank. Supplementary cutoff walls of concrete or impermeable clay extending laterally from the tank may be used to assist in controlling the water table in the locality of the tank. The lower portion of the uphill wall of the tank can be constructed of stone, brick, or other material so placed that water may move freely into the tank from the formation. Backfill of graded gravel and sand will aid in restricting movement of fine material from the formation toward the tank. The tank cover shall be cast in place to ensure a good fit. Forms should be designed to allow for shrinkage of concrete and expansion of form lumber. The cover shall extend down over the top edge of the tank at least 5 centimeters (2 inches). The tank cover shall be heavy enough so that it cannot be dislodged by children and shall be equipped for locking.
A drainpipe with an exterior valve shall be placed close to the wall of the tank, near the bottom. The pipe shall extend horizontally so as to clear the normal ground level at the point of discharge by at least (15) centimeters (6) inches. The discharge end of the pipe shall be screened to prevent the entrance of rodents and insects.
The overflow is usually placed slightly below the maximum water-level elevation and screened. A drain apron of rock shall be provided to prevent soil erosion at the point of overflow discharge. The supply outlet from the developed spring shall be located at least 15 centimeters (6 inches) above the drain outlet and properly screened. Care shall be taken in casting pipes into the walls of the tank to ensure a good bond with the concrete and freedom from honeycombs around the pipes.
SANITARY PROTECTION OF SPRINGS
Springs usually become contaminated when barnyards, sewers, septic tanks, cesspools, or other sources of pollution are located on higher adjacent land. In limestone formations however, contaminated material frequently enters the water-bearing channels through sinkholes or other large openings and may be carried along with ground water for long distances. Similarly, if material from such sources of contamination finds access to the tubular channels in glacial drift, this water may retain its contamination for long periods of time and for long distances.
The following precautionary measures will help to ensure developed spring water of consistently high quality:
-
Provide for the removal of surface drainage from the site. A surface drainage ditch shall be located uphill from the source so as to intercept surface-water runoff and carry it away from the source. Location of the ditch and the points at which the water should be discharged are a matter of judgment. Criteria used should include the topography, the subsurface geology, land ownership, and land use.
-
Construct a fence to prevent entry of livestock. Its location should be guided by the considerations mentioned in Item 1. The fence shall exclude livestock from the surface-water drainage system at all points uphill from the source.
-
Provide for access to the tank for maintenance, but prevent removal of the cover by a suitable locking device.
-
Monitor the quality of the spring water with periodic checks for contamination. A marked increase in turbidity or flow after a rainstorm is a good indication that surface runoff is reaching the spring.
SURFACE WATER
The selection and use of surface water sources for individual water supply systems require consideration of additional factors not usually associated with ground water sources. When small streams, open ponds, lakes, or open reservoirs must be used as sources of a water supply, the danger of contamination and the consequent spread of enteric diseases such as typhoid fever and dysentery are increased. As a rule, surface water shall be used only when ground water sources are not available or are inadequate. Clear water is not always safe, and the old saying that running water "purifies itself,” to drinking water quality within a stated distance is false.
The physical and bacteriological contamination of surface water makes it necessary to regard such sources of supply as unsafe for domestic use unless reliable treatment, including filtration and disinfection, is provided.
The treatment of surface water to ensure a constant, safe supply requires diligent attention to operation and maintenance by the owner of the system.
When ground water sources are limited, consideration shall be given to their development for domestic purposes only. Surface water sources can then provide water needed for stock and poultry watering, gardening, fire-fighting, and similar purposes. Treatment of surface water used for livestock is not generally considered essential. There is however, a trend to provide stock and poultry drinking water that is free from bacterial contamination and certain chemical elements.
Where the final resort must be made to surface water for all uses, a wide variety of sources, including farm ponds, lakes, streams, and the roof runoff of buildings may be considered. These sources are regarded, without exception, to be contaminated and their use cannot be condoned unless an individually tailored treatment process can be used which will make them safe and satisfactory. Such treatment may include aeration and the use of suitable filtration or precipitation devices to remove suspended matter, in addition to routine full-time disinfection. The milk producer and/or milk plant operator who is considering surface sources of water for milking, milkhouse, milk plant, receiving station, and/or transfer station operations shall receive the advance approval of the Health Officer and shall comply with all applicable requirements of the applicable state water control authority on the construction, protection, and treatment of the chosen supply.
Note: The EPA publishes a document entitled Manual of Individual Water Supply Systems that is an excellent source of detailed information on the development, construction, and operation of individual water systems and also contains a suggested well-drilling code.
III. DISINFECTION OF WATER SOURCES
All newly constructed or newly repaired wells shall be disinfected to counteract contamination introduced during construction or repair. Every well shall be disinfected immediately after construction or repair and flushed prior to bacteriological testing.
An effective and economical method of disinfecting wells and appurtenances is the use of calcium hypochlorite, containing approximately 70 percent available chlorine. This chemical can be purchased in granular form at hardware stores, swimming pool equipment supply outlets, or chemical supply houses.
When used in the disinfection of wells, calcium hypochlorite should be added in sufficient amounts to provide a dosage of approximately fifty (50) mg. available chlorine per liter (50mg/L) in the well water. This concentration is roughly equivalent to a mixture of 1 gram (0.03 ounce) of dry chemical per 13.5 liters (3.56 gallons) of water to be disinfected. A stock solution of disinfectant may be prepared by mixing 30 grams (1 ounce) of high-test hypochlorite with 1.9 liters (2 quarts) of water. Mixing is facilitated if a small amount of the water is first added to the granular calcium hypochlorite and stirred to a smooth watery paste free of lumps. The stock solution should be stirred thoroughly for 10 to 15 minutes. The inert ingredients should then be allowed to settle. The liquid containing the chlorine should be used and the inert material discarded. Each 1.9 liters (2 quarts) of stock solution will provide a concentration of approximately 50 mg/L when added to 378 liters (100 gallons) of water. The solution should be prepared in a clean utensil. The use of metal containers should be avoided, as they are corroded by strong chlorine solutions. Crockery, glass or rubber lined containers are recommended. Where small quantities of disinfectant are required and a scale is not available, the material can be measured with a spoon. A heaping tablespoonful of granular calcium hypochlorite weighs approximately 14 grams (½ ounce).
When calcium hypochlorite is not available, other sources of available chlorine such as sodium hypochlorite 12 to 15 percent of volume can be used. Sodium hypochlorite, which is also commonly available as liquid household bleach, with 5.25 percent available chlorine, can be diluted with 2 parts of water to produce the stock solution. One point nine (1.9) liters (2 quarts) of this solution can be used for disinfecting 378 liters (100 gallons) of water. Stock solutions of chlorine in any form will deteriorate rapidly unless properly stored. Dark glass or plastic bottles with airtight caps are recommended. Bottles containing solution should be kept in a cool place and protected from direct sunlight. If proper storage facilities are not available, the solution should always be prepared fresh immediately before use.
Complete information concerning the test for residual chlorine is included in the latest edition of Standard Methods for the Examination of Water and Wastewater (SMEWW), published by the American Public Health Association.
DUG WELLS
After the casing or lining has been completed, follow the procedure outlined below:
-
Remove all equipment and materials that will not form a permanent part of the completed structure.
-
Using a stiff broom or brush, wash the interior walls of the casing or lining with a strong solution (100 mg/L) of chlorine to ensure thorough cleaning and sanitizing.
-
Place the cover over the well and pour the required amount of chlorine solution into the well through the manhole or pipe opening just before inserting the pump cylinder and drop-pipe assembly. The chlorine solution should be distributed over as much of the surface of the water as possible to obtain proper diffusion of the chemical through the water hose or pipeline, as the line is being alternately raised and lowered. This method should be followed whenever possible.
-
Wash the exterior surface of the pump cylinder and drop pipe with the chlorine solution as the assembly is being lowered into the well.
-
After the pump has been set in position, pump water from the well and through the entire water distribution system to the milkhouse until a strong odor of chlorine is noted.
-
Allow the chlorine solution to remain in the well for at least twenty-four (24) hours.
-
After twenty-four (24) hours or more have lapsed, flush the well to remove all traces of chlorine.
DRILLED, DRIVEN, AND BORED WELLS
After the casing or lining has been completed, follow the procedure outlined below:
-
Remove all equipment and materials that will not form a permanent part of the completed structure.
-
When the well is being tested for yield, the test pump should be operated until the well water is clear and as free from turbidity as possible.
-
After the testing equipment has been removed, slowly pour the required amount of chlorine solution into the well just before installing the permanent pumping equipment. Diffusion of the chemical with the well water may be facilitated as previously described.
-
Wash the exterior surface of the pump cylinder and drop pipe with chlorine solution as the assembly is being lowered into the well.
-
After the pump has been set in position, operate the pump until the water discharged through the entire distribution system to waste has a distinct odor of chlorine. Repeat this procedure a few times, at one (1) hour intervals, to ensure complete circulation of the chlorine solution through the column of water in the well and the pumping equipment.
-
Allow the chlorine solution to remain in the well for at least twenty-four (24) hours.
-
After twenty-four (24) hours or more have elapsed, flush the well to remove all traces of chlorine. The pump should be operated until water discharged to waste is free from the chlorine odor.
In the case of deep wells having a high water level, it may be necessary to resort to special methods of introducing the disinfecting agent into the well so as to ensure proper diffusion of chlorine throughout the well.
The following method is suggested:
Place the granulated calcium hypochlorite in a short section of pipe capped at both ends. A number of small holes should be drilled through each cap or into the sides of the pipe. One (1) of the caps should be fitted with an eye to facilitate attachment of a suitable cable. The disinfecting agent is distributed when the pipe section is lowered and raised throughout the depth of the water.
WATER-BEARING STRATA
Sometimes a well is encountered that does not respond to the usual methods of disinfection. A well like this has usually been contaminated by water that entered under sufficient head to displace water into the water-bearing formation. The displaced water carries contamination with it. The contamination that has been carried into the water-bearing formation can be eliminated or reduced by forcing chlorine into the formation. Chlorine may be introduced in a number of ways, depending on the construction of the well. In some wells, it is advisable to chlorinate the water and then add a considerable volume of a chlorine solution in order to force the treated water into the formation. When this procedure is followed, all chlorinated water should have a chlorine strength of approximately 50 mg/L. In other wells, such as the drilled well cased with standard weight casing pipe, it is entirely practicable to chlorinate the water, cap the well, and apply a head of air. When air is alternately applied and released, a vigorous surging effect is obtained and chlorinated water is forced into the water bearing formation. In this procedure, the chlorine strength of the treated water in the well will be reduced by dilution as it mixes with the water in the water-bearing formation. Therefore, it is advisable to double or triple the quantity of chlorine compound to be used so as to have a chlorine strength of one (100) to one hundred, (150 mg/L) in the well as the surging process is started. After treating a well in this manner, it is necessary to flush it to remove the excess chlorine.
DISINFECTION OF SPRINGS
Springs and encasements should be disinfected by a procedure similar to that used for dug well. If the water pressure is not sufficient to raise the water to the top of the encasement, it may be possible to shut off the flow and thus keep the disinfectant in the encasement for twenty-four (24) hours. If the flow cannot be shut off entirely, arrangements should be made to supply disinfectant continuously for as long a period as practicable.
DISINFECTION OF WATER DISTRIBUTION SYSTEMS
These instructions cover the disinfection of water distribution systems and attendant standpipes or tanks. It is always necessary to disinfect a water system before placing it in use under the following conditions:
-
Disinfection of a system that has been in service with raw or polluted water preparatory to transferring the service to treated water.
-
Disinfection of a new system upon completion and preparatory to placing in operation with treated water or water of satisfactory quality.
-
Disinfection of a system after completion of maintenance and repair operations.
The entire system, including tank or standpipe, should be thoroughly flushed with water to remove any sediment that may have collected during operation with raw water. Following flushing, the system should be filled with a disinfecting solution of calcium hypochlorite and treated water. This solution is prepared by adding 550 grams (1.2 pounds) of high-test (70 percent) calcium hypochlorite to each 3,785 liters (1,000 gallons) of water. A mixture of this kind provides a solution having not less than (100 mg/L) of available chlorine.
The disinfectant should be retained in the system, tank, or standpipe, if included, for not less than twenty-four (24) hours, then examined for residual chlorine and drained out. If no residual chlorine is found present, the process should be repeated. The system is next flushed with treated water and put into operation.
IV. CONTINUOUS WATER DISINFECTION
CHEMICAL DISINFECTION OF WATER
Water supplies which are otherwise deemed satisfactory, but which prove unable to meet the bacteriological standards prescribed herein, shall be subjected to continuous disinfection. The individual character of the supply shall be investigated and a treatment program developed, which shall produce a safe supply as determined by bacteriological testing.
For numerous reasons, including economy, effectiveness, stability, ease of use, and availability, chlorine is by far the most popular chemical agent employed for the disinfection of water supplies. This does not preclude the use of other chemicals or procedures demonstrated to be safe and effective. The amount necessary to provide adequate protection varies with the supply and the amount of organic and other oxidizable material that it contains. Proper disinfection can only be assured when a residual concentration of chlorine remains, for bactericidal activity, after the demands of these other substances are met. In general, these factors exert the most important influences on the bactericidal efficiency of chlorine:
-
Free chlorine residual; the higher the residual, the more effective the disinfection and the faster the disinfection rate.
-
Contact time between the organism and the disinfectant; the longer the time, the more effective the disinfection.
-
Temperature of the water in which contact is made, the lower the temperature, the less effective the disinfection.
-
The pH of the water in which contact is made; the higher the pH, the less effective disinfection.
For example, when a high pH and low temperature combination is encountered in a water, either the concentration of chlorine or the contact time shall be increased. Likewise, chlorine residual will need to be increased if sufficient contact time is not available in the distribution system before the water reaches the first user.
SUPERCHLORINATION – DECHLORINATION
Superchlorination - The technique of superchlorination involves the use of an excessive amount of chlorine to destroy quickly the harmful organisms that may be present in the water. If an excessive amount of chlorine is used, free chlorine residual will be present. When the quantity of chlorine is increased, disinfection is faster and the amount of contact time required ensuring safe water is decreased.
De-chlorination - The de-chlorination process may be described as the partial or complete reduction of any chlorine present in the water. When de-chlorination is provided in conjunction with proper superchlorination, the water will be both properly disinfected and acceptable to the consumer for domestic or culinary uses.
De-chlorination can be accomplished in individual water systems by the use of activated carbon de-chlorinating filters. Chemical de-chlorination by reducing agents such as sulphur dioxide or sodium thiosulfate can be used for batch de-chlorination. Sodium thiosulfate is also used to de-chlorinate water samples prior to submission for bacteriological examination.
DISINFECTION EQUIPMENT
Hypochlorinators are the most commonly employed equipment for the chemical elimination of bacteriological contamination. They operate by pumping or injecting a chlorine solution into the water. When properly maintained, hypo-chlorinators provide a reliable method for applying chlorine to disinfect water.
Types of hypo-chlorinators include positive displacement feeders, aspirator feeders, suction feeders, and tablet hypo-chlorinators. This equipment can be readily adapted to meet the needs of other systems of treatment, which require the regulated discharge of a solution into the supply.
Positive Displacement Feeders - A common type of positive displacement hypo-chlorinator is one (1) that uses a piston or diaphragm pump to inject the solution. This type of equipment, which is adjustable during operation, can be designed to give reliable and accurate feed rates. When electricity is available, the stopping and starting of the hypo-chlorinator can be synchronized with the pumping unit. A hypo-chlorinator of this kind can be used with any water system. However, it is especially desirable in systems where water pressure is low and fluctuating.
Aspirator Feeders - The aspirator feeder operates on a simple hydraulic principle that employs the use of the vacuum created when water flows either through a venturi tube or perpendicular to a nozzle. The vacuum created draws the chlorine solution from a container into the chlorinator unit where it is mixed with water passing through the unit and the solution is then injected into the water system. In most cases, the water inlet line to the chlorinator is connected to receive water from the discharge side of the water pump, with the chlorine solution being injected back into the suction side of the same pump. The chlorinator operates only when the pump is operating. Solution flow rate is regulated by means of a control valve; pressure variations are known to cause changes in the feed rate.
Suction Feeders - One (1) type of suction feeder consists of a single line that runs from the chlorine solution container through the chlorinator unit and connects to the suction side of the pump. The chlorine solution is pulled from the container by suction created by the operating water pump.
Another type of suction feeder operates on the siphon principle with the chlorine solution being introduced directly into the well. This type also consists of a single line, but the line terminates in the well below the water surface instead of the influent side of the water pump. When the pump is operating, the chlorinator is activated so that a valve is opened and the chlorine solution is passed into the well.
Tablet Chlorinator: These hypo-chlorinators inject water into a bed of concentrated calcium hypochlorite tablets. The result is metered into the pump suction line.
ULTRAVIOLET LIGHT DISINFECTION OF WATER
The use of ultraviolet light (UV) to disinfect drinking water has been demonstrated to be an effective process that can inactivate microbes generally targeted by standard chemical disinfectants as well as pathogens that are resistant to other treatments such as Cryptosporidium. However, in the design of a water treatment system with UV light, the dairy farm, milk plant, receiving station, or transfer station permit holder must exercise care to ensure that all other requirements of these rules relating to source, protection from contamination, and chemical and physical characteristics are met. UV disinfection does not change the chemical or physical characteristics of the water such as reducing or removing turbidity, mineral levels, or arsenic, etc., so additional treatment, if otherwise dictated, may still be required. Nor does UV treatment provide residual disinfection. Some supplies may require routine chemical disinfection, including the maintenance of a residual disinfectant throughout the distribution system, and there may continue to be a need for the periodic flushing and disinfection of the water distribution system.
In addition, materials present in water can give rise to significant transmission difficulties so that it may be necessary to pre-treat some supplies to remove excessive turbidity and color.
Color, turbidity, and organic impurities can interfere with the transmission of UV energy and may decrease the disinfection efficiency below levels required to ensure the destruction of pathogenic organisms. In general, color and turbidity measurements do not provide an accurate measure of their impact on UV disinfection efficacy. Percent UV Transmissivity (% UVT) multiplied by time measures disinfection efficiency.
As a result, an in-line UVT analyzer is needed to assure that the proper dose is provided on a continuing basis, and it may be necessary to pre-treat the water supply to assure consistent water quality.
The use of UV to meet the bacteriological requirements of the PMO is acceptable provided the equipment used meets the criteria described herein. Water systems that are within the scope of the U.S. Safe Drinking Water Act as amended and 40 CFR Part 141, or state programs that have adopted these requirements, shall be regulated under this act and these regulations. Individual water systems that are not regulated under this act and regulations may be continuously disinfected using UV light based technologies provided the following criteria are met.
Criteria for the Acceptability of a UV Disinfection Unit
-
When used to disinfect water to potable drinking water standards, UV light shall be applied so that the entire volume of water receives at least the following dose: UV at 2,537 Angstrom (254 nanometers) at 186,000 microwatt-seconds per square centimeter or equivalent to achieve an EPA log virus reduction equivalent dose.
-
A flow or time delay mechanism shall be provided so that all water moving past the flow stop or divert valve receives the minimum dose required above.
-
The unit shall be designed to permit the frequent cleaning of the system without disassembly of the unit and shall be cleaned often enough to ensure that the system will provide the required dose at all times.
-
An accurately calibrated UV intensity sensor, properly filtered to restrict its sensitivity to the 2,500-2,800 Angstrom (250-280 nanometers) germicidal spectrum, shall measure the UV energy from the lamps. There shall be one (1) sensor for each UV lamp.
-
A flow-diversion valve or automatic shut-off valve shall be installed which will permit flow into the potable water lines only when at least the minimum required UV dosage is applied. When power is not being supplied to the unit, the valve shall be in a closed (fail-safe) position which shall prevent the flow of water into the potable water lines.
-
An automatic flow control valve, accurate within the expected pressure range, shall be installed to restrict flow to the maximum design flow of the treatment unit so that the entire volume of water receives the minimum dose required above.
-
The materials of construction shall not impart toxic materials into the water either as a result of the presence of toxic constituents in the materials of construction or as a result of physical or chemical changes resulting from exposure to UV energy.
Criteria for the Acceptability of a UV Disinfection Unit For Farm Water Supplies with a Flow Rate Less than Twenty (20) Gallons Per Minute
-
When used to disinfect water to potable drinking water standards, UV light shall be applied so that the entire volume of water receives at least a minimum reduction equivalent does of UV at 2,537 Angstrom (254 nanometers) of 40,000 microwatt-seconds per square centimeter.
-
A flow or time delay mechanism shall be provided so that all water moving past the flow stop or divert valve receives the minimum dose required above.
-
The unit shall be designed to permit the frequent cleaning of the system without disassembly of the unit and shall be cleaned often enough to ensure that the system will provide the required dose at all times.
-
An accurately calibrated UV intensity sensor, properly filtered to restrict its sensitivity to the 2,500-2,800 Angstrom (250-280 nanometers) germicidal spectrum, shall measure the UV energy from the lamps. There shall be one (1) sensor for each UV lamp.
-
A flow-diversion valve or automatic shut-off valve shall be installed which shall permit flow into the potable water lines only when at least the minimum required UV dosage is applied. When power is not being supplied to the unit, the valve shall be in a closed (fail-safe) position which shall prevent the flow of water into the potable water lines.
-
An automatic flow control valve, accurate within the expected pressure range, shall be installed to restrict flow to the maximum design flow of the treatment unit so that the entire volume of water receives the minimum dose required above.
-
The materials of construction shall not impart toxic materials into the water either as a result of the presence of toxic constituents in the materials of construction or as a result of physical or chemical changes resulting from exposure to UV energy.
Note: Existing water supplies which otherwise comply with the applicable requirements of this appendix may continue to use UV disinfection systems that were accepted under M-a-18 (Use of Ultraviolet Process for Disinfection of Water). Replacement systems shall comply with these rules.
V. WATER RECLAIMED FROM MILK AND MILK PRODUCTS AND FROM HEAT EXCHANGERS OR COMPRESSORS IN MILK PLANTS
Water reclaimed from Grade “A” milk and milk products may be reused in a milk plant. Water reclaimed from non-Grade “A” milk and milk products may also be reused in a milk plant provided that the design and operation of the equipment used to reclaim water meets the requirements of these rules. Water utilized for heat exchanger purposes in plate or other type heat exchangers or compressors, except those utilizing gaskets to separate oil and water, in Grade "A" milk plants may be reclaimed for milk plant operations. The three (3) general categories for reclaimed water use are:
CATEGORY I. USED FOR POTABLE WATER PURPOSES
Reclaimed water to be used for potable water purposes, including the production of culinary steam, shall meet the following requirements and shall be documented:
-
Water shall comply with the Bacteriological Standards of Appendix G, and, in addition, shall not exceed a total plate count of 500 per milliliter (500/mL).
-
Samples shall be collected daily for two (2) weeks following initial approval of the installation and semi-annually thereafter. Provided, that daily tests shall be conducted for one (1) week following any repairs or alteration to the system.
-
For water reclaimed from milk and milk products, a standard turbidity of less than five (5) units; or an electrical conductivity (EC) maintained in correlation with an organic content of less than twelve (12) mg/L, as measured by the chemical oxygen demand or permanganate-consumed test.
-
For water reclaimed from milk and milk product, automatic fail-safe monitoring devices located at any point in the reclaimed water line prior to the storage vessel shall be used to monitor and automatically divert to the sewer any water that exceeds the standard.
-
The water shall be of satisfactory organoleptic quality and shall have no off-flavors, odors, or slime formations.
-
The water shall be sampled and tested organoleptically at weekly intervals.
-
Approved chemicals such as chlorine with a suitable detention period, or UV disinfection that complies with the criteria in Appendix D may be used to suppress the development of bacterial growth and prevent the development of tastes and odors.
-
When chemicals are added, they shall be added by an automatic proportioning device prior to the water entering the storage vessel to assure satisfactory quality water in the storage vessel at all times.
-
When chemicals are added, a daily testing program for such added chemicals shall be in effect and such chemicals shall not add substances that will prove deleterious to the use of the water or contribute to product contamination.
-
The storage vessel(s) and/or any balance tank(s) shall be properly constructed of such material that it will not contaminate the water and can be satisfactorily cleaned.
-
The distribution system within a milk plant for such reclaimed water shall be a separate system with no cross-connections to a municipal or private water system.
12, All physical, chemical, and microbiological tests shall be conducted in accordance with the latest edition of SMEWW.
- If water reclaimed from milk and milk products is used for heat exchange in a raw milk heat exchanger, the reclaimed water shall be protected in the following manner:
(a) Heat exchangers of this type shall be so designed, installed, and operated that the heat transfer-medium side of the heat exchanger, in the raw milk or milk product section, will automatically be under greater pressure than the raw milk or milk product side at all times.
(b) The reclaimed water between its outlet from the heat exchanger and the nearest point downstream open to the atmosphere shall rise to a vertical elevation of at least 30.5 centimeters (12 inches) above any raw milk or milk product in the system and shall be open to the atmosphere at this or a higher elevation.
(c) The heat-transfer water circuit shall be full of water at the beginning of the run and loss of water from the circuit shall be automatically and immediately replenished whenever raw milk or milk product is present in the heat exchanger.
(d) The heat exchanger shall be designed and installed so that all raw milk or milk product shall drain freely back to the upstream supply tank when the raw milk or milk product pumps are shut down and when the raw milk or milk product line is disconnected from the heat exchanger outlet.
(e) Any pump located between the raw milk or milk product inlet to the heat exchanger and the balance tank shall be designed and installed to operate only when water is flowing through the heat-transfer section of the heat exchanger and when the pressure of the heat-transfer water is higher than the pressure of the raw milk or milk product. This may be accomplished by wiring the booster pump so that it shall only operate if:
(1) The heat-transfer water pump is in operation.
(2) The heat-transfer water pressure exceeds, by at least 6.9 kPa (1 psi), the raw milk or milk product pressure in the regenerator. A differential pressure controller shall be installed at the raw milk or milk product inlet and the heat-transfer water outlet of the heat exchanger. The raw milk or milk product booster pump shall be wired so that it cannot operate unless the differential pressure is met. The accuracy of the required differential pressure controller shall be checked by the Health Officer on installation, quarterly thereafter, and following repair or replacement.
(f) Provisions shall be made for cleaning the reclaimed water side of the raw milk heat exchanger and associated piping from the evaporator and/or membrane processes to the reclaimed water storage vessel.
(g) The reclaimed water side of the raw milk heat exchanger and required frequency as the equipment generating the reclaimed water.
Note: Water reclaimed from raw milk membrane processes shall not be used for Category I purposes unless it has been heat-treated at times and temperatures which meet at least the minimum times and temperatures provided for in the definition of pasteurization of these rules or undergone an equivalent process found to be acceptable to FDA and the Health Officer.
CATEGORY II. USED FOR LIMITED PURPOSES
Reclaimed water may be used for the following limited purposes including:
-
Production of culinary steam.
-
Pre-rinsing of the product surfaces where pre-rinses will not be used in milk or milk products.
-
Cleaning solution make-up water.
-
Non-recirculated heat exchange media used against unpasteurized milk or milk products or acid whey provided it complies with Item 1. as cited below.
-
Non-recirculated heat exchange media used against pasteurized milk and milk products with the plate or double/triple tube type heat exchanger designed and operated in accordance with Item 15p.(B)10. Provided that for these uses, Items 3-11 of Category I are satisfied and shall be documented. Or, in the case of reclaimed water from heat exchangers or compressors, Items 5-11 are satisfied and shall be documented.
-
There is no carry-over of water from one (1) day to the next, and any water collected is used promptly; or
(a) The temperature of all water in the storage and distribution system is maintained either at 7°C (45°F) or below, or at 63°C (145°F) or higher by automatic means; or
(b) The water is treated with a suitable, approved chemical to suppress bacterial propagation by means of an automatic proportioning device, or UV disinfection that complies with the criteria in Appendix D, prior to the water entering the storage tank; or
(c) The water shall comply with the Bacteriological Standards of Appendix G and, in addition, shall not exceed a total plate count of 500 per milliliter (500/mL). Samples shall be collected daily for two (2) weeks following initial approval of the installation and semi-annually thereafter. Provided, that daily tests shall be conducted for one (1) week following any repairs or alteration to the system. All physical, chemical, and microbiological tests shall be conducted in accordance with the latest edition of SMEWW; and that,
-
Distribution lines and hose stations are clearly identified as "limited use reclaimed water.”
-
Water handling practices and guidelines are clearly described and prominently displayed at appropriate locations within the milk plant.
-
These water lines are not permanently connected to product vessels without a break to the atmosphere and sufficient automatic controls to prevent the inadvertent addition of this water to product streams.
CATEGORY III. USE OF RECLAIMED WATER NOT MEETING THE REQUIREMENTS OF THIS SECTION
Reclaimed water not meeting the requirements of this section may be used as feed-water for boilers, not used for generating culinary steam, or in a thick, double walled, enclosed heat exchanger.
VI. WATER RECLAIMED FROM HEAT EXCHANGER PROCESSES OR COMPRESSORS ON GRADE “A” DAIRY FARMS
Potable water utilized for heat exchange purposes in plate or other type heat exchangers or compressors on Grade “A” dairy farms may be salvaged for the milking operation if the following criteria are met:
-
The water shall be stored in a storage vessel properly constructed of such material that it will not contaminate the water and be designed to protect the water supply from possible contamination.
-
The storage vessel shall be equipped with a drain and access point to allow for cleaning.
-
No cross-connection shall exist between this supply and any unsafe or questionable water supply or any other source of pollution.
-
There are no submerged inlets through which this supply may be contaminated.
-
The water shall be of satisfactory organoleptic quality and shall have no off-flavors or odors.
-
The water shall comply with the Bacteriological Standards of Appendix G.
-
Samples shall be collected and analyzed prior to initial approval and semi-annually thereafter.
-
Approved chemicals such as chlorine with a suitable retention period, or UV disinfection that complies with the criteria in Appendix D, may be used to suppress the development of bacterial growth and prevent the development of tastes and odors.
-
When chemicals are added, a monitoring program for such added chemicals shall be in effect and such chemicals shall not add substances that will prove deleterious to the use of the water or contribute to product contamination.
-
If the water is to be used for the sanitizing of teats or equipment, backflush systems, approved sanitizers such as iodine, may be added by an automatic proportioning device located downstream from the storage vessel but prior to its end-use application.
Note: Water from the current milking obtained directly from the discharge of a raw milk heat exchanger may be utilized for the one (1) time pre-rinsing of dairy equipment or for non- potable uses. This heat exchange water may be used if:
The water is used for the one (1) time pre-rinsing of milking equipment, including milk lines, milking claw assembly, milk receiver, etc., and discharged to waste.
The water is collected directly from the plate heat exchanger into the wash vat or utensil sink.
The water piping system shall meet the requirements of Item 8r of these rules.
VII
I. TOWER WATER DIAGRAMS
Figure 8. Tower Water Cooling Supplied Directly from a Tower Water Distribution Line Without a Balance Tank
Figure 9. Tower Water Cooling Using a Balance Tank Overflow Higher than the Heat Exchanger with Local Tower Water Supply Pump
Figure 10. Tower Water Cooling Using a Balance Tank Overflow Higher than the Heat Exchanger with a Bypass Line and a Local Tower Water Return Pump
Figure 11. Tower Water Cooling Using a Balance Tank Lower than the Heat Exchanger with a Local Tower Water Supply Pump
Figure 12. Tower Water Cooling Using a Balance Tank Lower than the Heat Exchanger with a Bypass Line and a Local Tower Water Return Pump
VIII
I. DRAWINGS OF CONSRUCTION DETAILS FOR WATER SOURCES
Note: The following Figures 13-30 are taken from The Manual of Individual Water Supply Systems, EPA publication number EPA-430-9-73-003.
Figure 13. Bored Well with Driven Well Point
Figure 14. Drilled Well with Submersible Pump
Figure 15. Dug Well with Two-Pipe Jet Pump Installation
Figure 16. Pumphouse
Figure 17. Spring Protection
Figure 18. Pond
Figure 19. Schematic Diagram of a Pond Water Treatment System
Figure 20. Cistern
Figure 21. Typical Concrete Reservoir
Figure 22. Pit-less Adapter with Submersible Pump Installation for Basement Storage
Figure 23. Clamp-on Pitless Adapter with Concentric External Piping for “Shallow Well” Pump Installation
Figure 24. Pitless Unit with Concentric External Piping for Jet Pump Installation
Figure 25. Weld-on Pitless Adapter with Concentric External Piping for "Shallow Well" Pump Installation
Figure 26. Well Seal for Jet Pump Installation
Figure 27. Well Seal for Submersible Pump Installation
Figure 28. Typical Valve and Box, Manhole Covers, and Piping Installation
Figure 29. Suction Feeder
Figure 30. Positive Displacement Chlorinator
History
- Author: G. M. Gallaspy, Jr.
- Authority: Code of Ala. 1975, §§22-2-2, 22-20-7.
- Repealed and New Rule: Filed October 18, 2018; effective December 2, 2018.
Ala. Admin. Code r. 420-3-16-AE Appendix E - Examples of 3-Out-Of-5 Compliance Enforcement Procedures
The following tables provide several useful examples in the application of the enforcement system described in Section 6. While the illustrations given relate only to pasteurized milk bacterial counts and somatic cell counts of raw milk, the method is applied, in like fashion, to the enforcement of established standards for cooling temperature, coliform limits, etc. Pasteurized milk or milk product that shows a positive phosphatase reaction and milk or milk product in which the presence of drug residue, pesticides, or other adulterants is found, shall be dealt with as indicated in 420-3-16(3) and 420-3-16(8), respectively.
TABLE 11
| WORK WATER VOLUME OF VARIOUS SIZED PIPELINES | | | | --- | --- | --- | | Date | Bacterial Count Per mL | Enforcement Action As Applied To A Standard of 20,000/mL | | 01/05/2013 | 6,000 | No Action Required | | 01/28/2013 | 11,000 | No Action Required | | 2/11/2013 | 12,000 | No Action Required | | 3/15/2013 | 22,000 | Violative; written notice to the milk plant, two (2) of the last four (4) counts exceed the standard. (This notice shall be in effect as long as two [2] of the last four [4] consecutive samples exceed the standard). Additional sample required within twenty-one (21) days from the date of the notice, but not before the lapse of three (3) days. | | 04/02/2013 | 9,000 | No Action Required. | | 4/19/2013 | 51,000 | Violative; (three [3] of last five [5] counts exceed the standard) Required regulatory actions: 1. Suspend the milk plant permit; or 2. Forego permit suspension, provided the milk or milk products(s) in violation are not sold as Grade “A” milk or milk product(s); or 3. Impose monetary penalty in lieu of permit suspension, provided the milk or milk product(s) in violation are not sold as Grade “A” milk or milk product(s). | | 4/23/2013 | | Issue temporary permit (if applicable) after a milk plant inspection. Begin accelerated sampling schedule. Samples shall then be taken at the rate of not more than two (2) per week on separate days within a three (3) week period in order to determine compliance with the appropriate standard as determined in accordance with Rule 420-3-16-.07 of these rules. (Refer to Rule 420-3-16-.04 of these Rules). | | 4/25/2013 | 11,000 | No Action Required. | | 4/29/2013 | 3,000 | No Action Required. | | 05/04/2013 | 22,000 | Violative; No Action Required. Note: Samples collected prior to 04/23/2013 are not used for subsequent bacterial count enforcement purposes | | 05/09/2013 | 5,000 | Permit fully reinstated. |
TABLE 12
| WORK WATER VOLUME OF VARIOUS SIZED PIPELINES | | | | --- | --- | --- | | Date | CONFIRMED SOMATIC CELL COUNTS PER mL | Enforcement Action As Applied To A Standard of 750,000/mL | | 07/10/2013 | 500,000 | No Action Required | | 08/15/2013 | 600,000 | No Action Required | | 10/01/2013 | 800,000 | Violative; No Action Required | | 11/07/2013 | 900,000 | Violative; Written notice to producer, two (2) of the last four (4) counts exceed the standard. (This notice shall be in effect as long as two [2] of the last four [4] consecutive samples exceed the standard). Additional sample required within twenty-one (21) days from the date of the notice, but not before the lapse of three (3) days. | | 11/14/2013 | 1,200,000 | Violative (three [3] of the last five [5] counts exceed the standard); Required regulatory actions: 1. Suspend producer permit; or 2. Forego permit suspension, provided the milk in violation is not sold as Grade “A”; or 3. Impose monetary penalty in lieu of permit suspension, provided the milk in violation is not sold or offered for sale as Grade “A” product. Except that a milk producer may be assessed a monetary penalty in lieu of permit suspension for violative counts provided: If the monetary penalty is due to a violation of the somatic cell count standard, the Health Officer shall verify that the milk supply is within acceptable limits as prescribed in Section 7 of these rules. Samples shall then be taken at the rate of not more than two (2) week on separate days within a three (3) week period in order to determine compliance with the appropriate standard as determined in accordance with Section 6 of these rules. (Refer to Section 3) Note: The option to issue a monetary penalty in lieu of a permit suspension, as cited in 3. Above, shall not be applicable to a TPC authorized under the ICP. | | 11/18/2013 | 700,000 | Issue temporary permit (if applicable) after sampling indicates the milk is within the standards prescribed in Rule 420-3-16-.08. Begin accelerated sampling schedule as cited under 11/14/2013 | | 11/20/2013 | 800,000 | Violative; No Action Required Note: Samples collected prior to 11/18/2013 are not used for subsequent somatic cell count enforcement purposes. | | 11/24/2013 | 700,000 | No Action Required. | | 11/29/2013 | 550,000 | No Action Required. | | 12/03/2013 | 400,000 | Permit fully reinstated. |
History
- Author: G. M. Gallaspy, Jr
- Authority: Code of Ala. 1975, §§22-2-2, 22-20-7.
- Repealed and New Rule: Filed October 18, 2018; effective December 2, 2018.
Ala. Admin. Code r. 420-3-16-AF Appendix F - Cleaning and Sanitization
I. METHODS OF SANITIZATION
CHEMICAL
Certain chemical compounds are effective for the sanitization of milk containers, utensils, and equipment. These are contained in either in 40 CFR 180.940 and shall be used in accordance with label directions, or Electro-Chemical Activation (ECA) device manufacturer’s instructions if produced onsite in accordance with Section II below.
STEAM
When steam is used, each group of assembled piping shall be treated separately by inserting the steam hose into the inlet and maintaining steam flow from the outlet for at least five (5) minutes after the temperature of the drainage at the outlet has reached 94°C (200°F). The period of exposure required here is longer than that required for individual cans because of the heat lost through the large surface exposed to the air. Covers shall be in place during treatment.
HOT WATER
Hot water may be used by pumping it through the inlet if the temperature at the outlet end of the assembly is maintained to at least 77°C (170°F) for at least five (5) minutes.
II. CRITERIA FOR THE ONSITE PRODUCTION AND USE OF ELECTRO- CHEMICAL ACTIVATION (ECA) GENERATED HYPOCHLOROUS ACID FOR THE SANITIZATION OF MULTI-USE CONTAINERS, UTENSILS, AND EQUIPMENT
The following is a list of criteria that are required for on-site generation of ECA generated hypochlorous acid that was produced onsite and used as a sanitizer for the sanitization of multi-use containers, utensils, and equipment.
-
The ECA device manufacturer shall be registered with the EPA as a pesticidal device establishment pursuant to 40 CFR 152.500 and shall comply with the labeling requirements outlined in 40 CFR 156.10.
-
The minimum dilution percentage of the sanitizer shall be fifty (50) parts per million (ppm) free available chlorine (FAC) with a minimum contact time of thirty (30) seconds pursuant to the efficacy requirements for EPA DIS/TSS four (4) Sanitizer rinses, for previously cleaned milk-contact surfaces, and less than two-hundred (200) ppm FAC. The sanitizer produced shall meet the data requirements of 40 CFR Part 158 Data Requirements for Registration, Pesticide Assessment Guidelines – Subdivision G, 91-2(f), and its test documents shall be pursuant to Good Laboratory Practices (GLPs).
-
The salt used to generate the sanitizer shall be of food-grade quality rated at a minimum of 99.6 percent purity, and potable water shall be used to ensure quality and consistency of the sanitizer generated.
-
The ECA device and its solution concentrate storage containers shall be constructed of materials that do not impart toxic materials into the sanitizing solution either as a result of the presence of toxic constituents in the materials of construction or as a result of physical or chemical changes that may occur during the ECA process.
-
The ECA solution concentrate storage containers shall be labeled with the following:
(a) Contents.
(b) Environmental Protection Agency (EPA) establishment number for the ECA device manufacturer.
(c) Dilution percentage instructions for use and storage conditions, including the shelf-life.
(d) A list of its active and inert ingredients.
(e) Other required standard safety data disclosures, formerly referred to as Material Safety Data Sheet (MSDS).
-
The ECA device used to produce the hypochlorous sanitizer shall control and record the parameters to ensure that the ECA device is operating within its design limits and provides an effective real time notification or alarm and shall shut down when it falls out of the required range as recommended by the ECA device manufacturer.
-
Standard measurement methods such as FAC titration or chlorine test strips shall be used to verify that the concentration of the ready to use sanitizer being applied is in a range between 50 ppm and 200 ppm. Measurement equipment shall be checked, calibrated, and measurements recorded. All records shall be accessible to the Health Officer for inspection. Electronically generated records for FAC concentrations, if used, shall meet the criteria specified in Appendix H, Section V.
III. EVAPORATING, DRYING, AND DRY PRODUCT EQUIPMENT CLEANING
CLEANING
Cleaning of Evaporators and Condensers - Some evaporators are designed so that the milk or milk product is exposed to large surface areas for a long period of time at temperatures conducive to the growth of microorganisms.
Pipelines and/or equipment designed for automated mechanical cleaning of evaporators should meet the following requirements:
(a) A pH recording device should be installed in the return solution line to record the pH and time which the line or equipment is exposed during the cleaning and sanitizing operation.
(b) These pH recording charts should be identified, dated, and retained for three (3) months.
(c) During each official inspection, the Health Officer should examine and initial the pH recording charts to verify the time of exposure to the cleaning solutions and their pH.
The following are suggested procedures for cleaning and sanitizing evaporators and condensers:
The surface area inside an evaporator is extremely large. Not only is there a large separator chamber and vapor lines but steam chests may also have as many as 500 to 1400 heating tubes from 3 to 15 meters 10 to 50 feet long. The total surface area may be 4,000 to 35,000 square feet, which may require large volumes for recirculation. This surface area shall be cleaned and sanitized carefully or it will contaminate the milk or milk product. The operating temperatures in an evaporator are very close to the growing temperatures of thermoduric and certain mesophilic types of bacteria. The first effect may operate at 60°C (140°F) to 77°C (170°F), the second effect at 52°C (125°F) to 63°C (145°F), and the third effect at 38°C (100°F) to 49°C (120°F). The product being evaporated is often re-circulated in the last effect several times until the right concentration is reached, which may give bacteria ample time to grow. A clean evaporator operates more efficiently. It is necessary to clean the evaporators after long periods of operations because burned-on material reduces heat transfer and efficiency. A point is reached where it will be more economical to stop and clean up than to continue to operate. Evaporators need cleaning for sanitary reasons as well as for efficient operation. Tube chests and heating plates shall be cleaned to get good heat transfer. If vapor lines are not cleaned, it is possible to get a back surge of vapor when the vacuum is released. This can carry soil back into the milk or milk product thus lowering the quality. This soil may drop into the thermo-compression unit, block passage of vapors, and actually prevent good operation. Compounds for cleaning are usually divided into two (2) main groups:
(a) The alkaline cleaners usually contain caustic with water conditioners, synthetic detergents, and foam depressants added to enhance cleaning action. The purpose of the alkaline cleaner is to digest the bulk of the soil. The alkaline solutions are usually run first at concentrations ranging from 1 percent to 3 percent at temperatures of 83°C (180°) to 88°C (190°F) for 30 to 60 minutes.
(b) Acid cleaners are usually food grade with synthetic detergents and inhibitors to prevent attack on metal surfaces. The purpose of acid cleaners is to remove mineral films, alkali cleaner residues, and shine the inside surfaces. Acid solutions are usually used last at concentrations of 0.2 percent to 0.5 percent at 60°C (140°F) to 71°C (160°F).
In all cases, cleaners and cleaning instructions should be followed as recommended by the manufacturer of the cleaning compound. It is also necessary to follow the recommendations and instructions of evaporator manufacturers. The evaporators operating with compressed ammonia require special cleaning precautions.
Cleaning Methods - There are four (4) basic methods of cleaning evaporators:
-
Boil-out;
-
Circulation;
-
Spray cleaning; or
-
A combination of the three methods.
(a) The boil-out method is the oldest, but it is still very effective. It is accomplished by rolling or boiling the cleaning solution under partial vacuum. Heat is applied by the evaporator and just enough vacuum is used to roll the solution. Cleaning solutions are elevated to the dome and upper parts by opening and closing the vacuum breaker. Hand-brushing of some areas is often necessary following boil-out because it is difficult to thoroughly clean the upper surfaces with this method.
(b) Circulation cleaning is a newer method of cleaning. The cleaning solution actually follows the milk or milk product path. The solution is circulated by returning it back to the starting point. Heat is applied by a pre-heater, tube chest, or steam jet, sometimes called a boil-out nozzle. This method is not adaptable to all types of evaporators and it is usually necessary to add spray cleaning devices to thoroughly clean separators and the bottom tube sheet in steam chests.
(c) Spray cleaning is the newest method of cleaning evaporators. Cleaning solutions are pumped through spray devices and distributed over the surfaces which are contacted by the milk or milk product. Heat is applied by a pre-heater, a surge tank, or on the run with live steam. When properly designed and operated spray cleaning systems are used, cleaning problems are at a minimum. Spray cleaning offers many advantages over boil-out or circulation methods of cleaning. Less water and less cleaning solution are required. This not only results in a saving of water, heat, and cleaners, but more concentrated cleaning solutions can be used giving faster, more effective cleaning. Heat for the rinse water and cleaning solutions is applied externally, preventing additional burn-on in tube chests. As the evaporator is not under vacuum, less heat is required to keep the solution hot, resulting in a saving of fuel. Higher temperatures can be used to improve cleaning efficiency. There are some disadvantages to spray cleaning. Spray devices cost extra money because they are specifically designed for almost every operation. Spray devices shall be properly placed and designed to cover the top of the dome in the separator, the tangential inlets, the vapor lines, sight glasses, and steam chest tubes. Spray cleaning may require additional stainless steel lines to convey the solution at the necessary volumes. Larger pumps are also required to pump the necessary volume of cleaning solution. Even with these disadvantages, the advantages of savings in heat, water, cleaning compound, and time outweigh the disadvantages.
(d) Sometimes there are advantages in using combined systems of cleaning. It may be possible to boil-out the steam chests and spray the separators. Sometimes it is possible to circulate the steam chests and spray clean the separators or other portions of the unit. Quite often the combined systems, especially the circulation in the spray system, will work best on certain types of evaporators.
(e) One of the biggest factors affecting the method of cleaning used is the type of evaporator. In a falling film type evaporator, circulation cleaning can be used to clean the tube chests and spray cleaning can be utilized to clean the evaporator chambers. When using a plate-type evaporator, circulation cleaning is best. In an internal type tube chest, a boil-out system for the tubes and spray cleaning of the separator works very well. With an external chest type evaporator, the entire unit can be spray cleaned. If it is a compressed ammonia operated evaporator, spray cleaning works well, and sanitizing should be done to eliminate any microorganisms which may have survived the cleaning regimen. Sanitizing can best be accomplished by using chemical sanitizers. Heat may be used if all surfaces are heated to 83°C (180°F) or higher. Since there is a tremendous investment in stainless steel evaporators, it is necessary to use cleaning and sanitizing products which do not corrode stainless steel. Chemical sanitizers can be applied through the spray equipment or they can be applied with fogging guns.
- High-Pressure Pump and High-Pressure Lines - The high-pressure pump and high-pressure line to the dryer nozzles may be cleaned as a separate circuit by connecting the line to the nozzle back to the drop tank and this tank connecting to the inlet of the high-pressure pump. The regular milk or milk product atomizing nozzles should be removed before cleaning is to be done.
Another method of cleaning the high-pressure pump and lines is to include this pump and high-pressure lines in the circuit when wet cleaning some types of spray dryers. In either case, a solution of 1-3 percent caustic heated to 72°C (160°F) should be circulated for at least thirty (30) minutes. A solution of inhibited acid should be pumped through the atomizing system as a daily procedure to remove the milkstone from the high-pressure pump and high-pressure line. A solution of inhibited acid should be recirculated a minimum of 10 to 15 minutes and followed by a rinse with potable water.
It is also recommended that the high-pressure pump head be disassembled as a daily procedure immediately following the final rinse and the parts be placed on a table or rack for air drying. When the pump is disassembled the parts are to be checked to see if they are clean, and to see if any maintenance is required to remove pits. Seats are also checked at this time. Since a high- pressure pump is subjected daily to extreme heavy duty, the valves and seats are recommended to be ground periodically to maintain uniform pressure on the atomizing nozzles. Prior to use, the entire system should be sanitized.
- Wet Cleaning of Dryers - There are several methods of wet cleaning dryers:
(a) The first method is hand-brushing. The cleaning personnel go into the dryer with buckets of cleaning solution and brush all surfaces of the dryer. The unit is then rinsed with a hose.
(b) Cleaning can also be done with hand-operated spray guns. These spray guns are pressure pumps which operate at high pressures in low volumes. In many cases, box-type dryers can be completely cleaned with the addition of a seven (7) foot extension on these pressure guns. By using high-pressure spray guns and cleaning compounds with a high synthetic detergent content, it is possible to remove very difficult soil.
(c) The third method of wet cleaning is by spray cleaning with various types of stationary or rotating spray devices. They usually operate at a high volume of low pressure in the range of 69 kPa (10 psi) to 138 kPa (20 psi). Constant spray coverage can be obtained when spray devices are properly designed. Usually several spray devices are required because of the many chambers, collectors, and down pipes within these units. Less time is required to do a complete job with spray cleaning. The systems are installed so that cleaning lines are easily connected to the spray devices and an effective return system. Spray cleaning time is much shorter than hand cleaning time, especially in large units. Spray cleaning eliminates the entry of cleaning personnel into the drying units. Silo or vertical type dryers are often 6.2 meters (20 ft.) to 30.4 meters (100 ft.) high and it is difficult and dangerous to clean by hand or by hand operated units. Spray cleaning eliminates the flavor contamination when switching to other milk or milk products. If an ungraded milk or milk product is run through the dryer, it is necessary to thoroughly clean before running a Grade “A” milk or milk product. There are disadvantages to spray cleaning. The spray devices shall be properly placed and designed to do the complete cleaning job. They shall be removable so as not to affect the air currents during operation. However, the advantages of safety plus cleaning time and consistently complete cleaning outweigh the disadvantages. A typical spray cleaning cycle might operate as follows:
(1) The various spray heads are placed in the dryer and securely fastened into place. The rinse water is pumped through the spray device and allowed to run down the side-walls of the drying units. Cleaning compounds which are mild alkaline or chlorinated cleaners are prepared at 0.3 percent concentration, heated to 71°C (160°F) to 83°C (180°F), and circulated for forty-five (45) minutes to one (1) hour. The unit is given a final rinse and is thoroughly dried. Occasionally acid type cleaners are used to control mineral films. Sanitizing with chemical sanitizers is a controversial subject. Sanitizing can be done with heat but it may be difficult to heat all surfaces to 83°C (180°F). Heating to 83°F (180°F) for ten (10) minutes does not kill spore formers. However, they are killed with many chemical sanitizers. Even if heat is used, it is recommended that chemical sanitizers be occasionally used. By pumping the sanitizer solution to the high-pressure pump or by fogging with high pressure, it is possible to completely cover the milk or milk product-contact surface. Actually, the unit shall be thoroughly dried before operation. Chlorine sanitizers may cause corrosion. Obviously, these compounds should be used with care. If chlorine is left on the dryer and heat is applied, the chlorine droplets will become hot and concentrate and cause pitting. When chlorinated cleaners are used, a dryer surface can be effectively cleaned and at least partially sanitized and the solution can be completely rinsed. Acid-synthetic detergent type sanitizers have been developed which are effective on spore formers. These compounds are germicidal, effective in hard water, and stable in hot or cold solutions. They have an advantage in that they are noncorrosive to dairy metal.
(2) It is not necessary to wet clean dryers on a daily basis. However, a schedule should be set up so cleaning is done periodically. As long as a dryer is operating continuously, it is not necessary to clean it from an efficiency standpoint. Some types of dryers require very little cleaning, maybe once each month; others require dry cleaning on a more frequent basis. It is necessary to clean and sanitize dryers if they are going to remain idle any appreciable length of time. Bacteria may grow in dryers which remain idle. Dryers shall be spray cleaned if they are improperly operated, causing burn-on in the drying chamber. Whenever fires develop inside the drying unit or when burn-on occurs, it is necessary to thoroughly clean at least the drying chambers. Quality is the key to the dry milk industry. There should be a program of cleaning and sanitizing of both evaporators and dryers. Better quality milk and milk products are produced in evaporators and dryers when thoroughly cleaned and sanitized on a regular basis.
- Dry Cleaning - It is very difficult to discuss proper cleaning procedures without also discussing proper operating procedures, especially the start-up and shutdown of the dryer. Assuming the dryer has been properly started and operated throughout the run or drying cycle, the first step in a successful cleaning operation is shutting the dryer down properly. The type of energy supplying heat to the dryer chamber, i.e., steam or gas, alters the proper shutdown technique. The correct procedure in shutting down a steam heated dryer is as follows:
(a) Shut off the main steam valve at the proper time.
(b) Maintain the proper dryer outlet temperature for drying by gradually reducing the output of the high-pressure pump until the residual heat of the steam coil is dissipated to a point where it does not maintain proper temperature or until the milk or milk product being pumped by the high-pressure pump does not maintain a satisfactory spray pattern.
(c) Keep the dry milk product removal system and conveying system in operation.
(d) Keep the air intake and exhaust fans on the dryer in operation until the main chamber is sufficiently cooled to provide a comfortable atmosphere for the cleaning personnel.
On a gas-fired spray dryer, the burner assembly has very little or no residual heat capacity. Therefore, the shutdown is more rapid. The correct procedure for shutting down a gas-fired dryer is as follows:
(a) Shut off the gas supply to the burner.
(b) Immediately shut off the high-pressure pump.
(c) Same procedure as steam heated dryer.
(d) After the above procedures have been accomplished, shut down the intake fan. Let the exhaust fan and vibrators or shakers continue to operate, along with the milk and milk product removal system. The exhaust fan should be severely dampered so that it induces only a small air-flow. A small auxiliary fan is sometimes used in lieu of the dampered exhaust fan. The use of either fan serves a twofold purpose: First, it is helpful to put the drying system under a slight negative pressure to reduce the tendency for milk or milk product to drift out of the system into the milk plant through open doors, etc. Secondly, it is vital to prevent thermal currents from creating a reverse air-flow through the drying system, which tends to deposit milk or milk product on the heating surfaces and plenum duct. Milk or milk product deposits on steam coils reduce their heating ability, create sediment, and conceivably bacterial problem areas. If the dryer is gas fired, there is a further hazard of fire. It is important; therefore, that the closure or covers supplied by the manufacturer be placed on the inlet air duct system simultaneous with the shutdown of the fan. After any prime milk or milk product has been removed from the drying system, the system is ready for cleaning. The cleaning personnel should be supplied each day with a freshly laundered set of coveralls, white cap, white face mask, and clean rubbers or boot covers (canvas or single-service plastic). Prior to donning the above uniform, the procedure is to remove the spray nozzles and pipes as these are normally cleaned with the liquid dryer feed equipment. With clean uniforms, proper brushes, and preferably vacuum cleaning equipment, the cleaning personnel enter the main desiccator chamber and start the cleaning process as far upstream as possible from the milk or milk product removal or pneumatic conveyor system:
(1) The first portion cleaned is the collector system. This is done by inserting a brush into the cloth tubes and brushing the length of the tube. Again, this can be done more satisfactorily by utilizing the special vacuum tools designed and available for this service.
(2) Remove the dust covers and brush or vacuum out the nozzle ports.
(3) Manually brush or vacuum the ceiling and walls of the drying chamber.
(4) Sweep or vacuum clean the floor of the dryer, placing milk or milk product in a container.
Note: Do not remove this milk or milk product by way of the milk and milk product removal system.
(5) Inspect the dryer for any inadvertent wet spraying or nozzle drippings that may have occurred during the drying cycle. Should either of these have occurred, the application of a minimum amount of water and effort will be required to remove the clinging material. Any moisture introduced shall be removed before operation begins because of its effect upon smooth milk or milk product flow and because it would establish a more favorable environment for bacterial growth if it were allowed to remain.
(6) Check the collector for loose or torn bags and any other mechanical checks necessary before leaving the dryer.
(7) Close the dryer securely and check the switches to make sure they are in the proper starting positions. At frequent intervals, not over a two (2) week period, the operator should clean and inspect the heated air intakes of the dryer, assuming that the dryer is properly operated during this time. However, should a malfunction occur where the dryer operator does not follow the procedures outlined for proper shutdown, it may require an inspection and cleaning at closer intervals. Frequent inspection will eliminate a source of sediment contamination.
(8) On start up after dry cleaning of the cloth collector dryer, the first two (2) bags of milk or milk product shall be discarded. This will allow for the removal of any milk or milk product remaining in the tubes and system after shutdown.
AUXILIARY DRY PRODUCT EQUIPMENT
- Sifters - In general, there are two (2) types of dry product sifters in use by the dry milk industry. These are the shaker type and the rotary or gyrating type. Both are designed to operate at various capacities either manually bagging or packaging from their outlet or designed for automatic packaging equipment.
For the general guidance of sifter manufacturers and the dry milk industry, the following screen size openings may be considered as recommended openings to result in satisfactory screening of the listed dry milk product:
TABLE 13
| SIEVE SIZES AND DESIGNATIONS | | | | | --- | --- | --- | --- | | Product | Sieve Designation From The American Society For Testing and Materials (ATSM) International E-11 | Maximum Sieve Opening (approximately) | | | | | MM | Inch | | Nonfat Dry Milk | #25 | 0.707 | 0.027 | | Dry Whole/Dry Buttermilk | #16 | 1.19 | 0.047 |
It is recognized that larger screen size openings may be necessary for sifting certain special dry milk products, such as "instant" products, and for classification of dry milk products into different particle sizes.
Openings referred to above are based on general experience as to what constitutes satisfactory screening to remove dry milk product lumps or potential dry milk product contamination, and also on the ability of most currently used sifters to successfully sift dry milk products through such size openings, without excessive loss of fine dry milk product into the "reject material" outlet. Other factors also affect loss, such as:
(a) Percent of "open area" in the screen used.
(b) Uneven flow rates to the sifter.
(c) Ratio of screening surface to dryer capacity.
(d) Amount and kind of mechanical energy applied to the screening surface.
(e) Sifter design and construction.
(f) Nature of dry product being sifted.
Screen opening dimensions may be obtained by any desired combination of wire thickness and number of wires per inch. For instance, if the screening surface is made of stainless steel woven wire, the 0.707 mm (0.027 of an inch) opening might be obtained by using 24 X 24 mesh market grade screen cloth made of wire 0.399 mm (0.014 of an inch) thick about 45 percent open area or by using 30 X 30 bolting cloth screen made of wire 0.185 mm (0.0065 of an inch) about 65 percent open area or by many other mesh-wire thickness combinations. These combinations allow a wide choice to obtain a desired balance between screen strength and percent open area. If materials other than stainless steel are used to construct the screening surface, similar combinations may be employed to achieve the desired opening size.
Recommendations for cleaning dry milk product sifters:
a. Dry Cleaning Program - The procedures set forth below should be followed:
(1) Completely dismantle and thoroughly vacuum or dry brush-clean all dry milk or milk product-contact surfaces of the dry milk sifter. Reassemble as soon as finished and make every effort to keep all parts dry.
(2) Check the sifter screen(s) for broken or displaced wires (threads) and for other openings around the frame of the screen, which might permit the passage of un-sifted dry milk product. Other parts of the sifter, including ball trays and balls, if used, should also be inspected for condition. Any necessary repair or replacement should be made as soon as possible.
(3) Flexible rubber or cloth connectors at the inlet and outlets of the sifter should be thoroughly cleaned daily following the procedures as recommended for the sifter. At this time, connectors should be closely examined for holes, cracks, or other damage.
Note: To facilitate removal for cleaning, the use of easily removable fastening devices are recommended.
(4) Thoroughly vacuum or dry brush-clean all external parts of the sifter, including the sifter frame and drive mechanism.
b. Wet Cleaning Program - The procedures set forth below should be followed:
(1) Completely dismantle as cited in a.(1) above; remove all loose dry milk product; then rinse all parts with clear water; and follow by a thorough hand-brushing of all parts, using a general purpose dairy cleaner. Rinse thoroughly to remove all evidence of cleaning solution or soil. It is recommended that hot water at 7°C (170°F) or above be used for rinsing in order to sanitize the equipment and to aid the subsequent drying.
(2) Allow all parts to air dry completely prior to reassembly.
(3) The wet wash should be done as frequently as necessary and should be done after each use if the sifter is not being used on a daily basis.
(4) After cleaning, drying, and reassembly, the dry milk product outlet should be protected from contamination.
c. General Recommendations
(1) Vacuum cleaning is preferred to brush-cleaning or cleaning with air under pressure as it decreases the dust drift problem to other areas of the milk plant.
(2) Brushes or vacuum cleaner fittings used for cleaning dry milk product-contact surfaces should not be used for cleaning non-dry milk product-contact surfaces or for other uses which might result in contamination. Such brushes and special fitting should be stored in an enclosed cabinet when not in use. For protection and housekeeping considerations, such cabinets preferably should be of non-wood construction and should have open mesh metal shelving.
Note: For additional details refer to 3-A Sanitary Standards for Sifters for Dry Milk and Dry Milk Products, Serial 26-##.
- Storage/Shipping Bins: The use of portable bins, totes, super sacks, or other portable storage/shipping containers shall comply with the construction requirements of Item 11p and the cleaning and sanitizing requirements of Item 12p of this these rules.
If interior bracing and ladders are used in milk plant storage bins, they shall be constructed of smooth rounded metal and be installed sufficiently far from the walls to prevent harborages.
Dry milk product entrance and discharge openings connected to the attending conveying equipment shall be dust-tight and shall be easily accessible for cleaning. Vents to the exterior shall be equipped with readily removable air filters of adequate capacity or readily removable covers. If air is to be introduced into the dry milk product zone, only filtered air shall be used, and it shall comply with the applicable standards of Appendix H. Auxiliary agitators or any other interior devices, if used, shall be designed to be smooth, crevice-free, and readily cleanable. The exterior surface of the bin should be smooth, hard finished, and readily cleanable. Hinges on covers, if used, shall be the take-apart type. Covers or doors shall be provided to enclose the dry milk product zone when dry milk product is not being dumped. These shall be so constructed that dirt or dust on the top will not slide or fall into the bin when the cover is open. Access openings shall be provided on all in-milk plant bins. Such openings should not be less than 45.7 centimeters (18 inches) in its smallest dimension. Covers shall be constructed without raised internal reinforcements and should be hinged and equipped with a quick opening device. The gaskets for such openings shall be made of solid material that is non-toxic, nonabsorbent, smooth, and unaffected by the dry milk product. Storage/shipping bins in continuous use either in the milk plant or in transporting dry milk products from one (1) milk plant to another should be cleaned according to manufacturer's recommendations when necessary. They may be cleaned by either approved dry cleaning methods or wet cleaned.
- Packaging and Packages - Packaging equipment for dry milk products will vary greatly as to their design depending upon whether the packages being filled are drums, bins or bags. Whatever equipment is used, it should be designed so as to protect the dry milk product from contamination from outside sources and from air during the packaging operation. All connections of conveying equipment to packaging devices should have dust-tight connections. All conveyors, ducts, belts, and screws used in connection with packaging equipment should be provided with a dust collector system, capable of eliminating any visible dust. All dry milk product hoppers, when used, should be provided with covers to properly protect the dry milk product from contamination. Hand-filling should not be permitted except for periods of adjustment of automatic weighing devices.
History
- Author: G. M. Gallaspy, Jr.
- Authority: Code of Ala. 1975, §§22-2-2, 22-20-7.
- Repealed and New Rule: Filed October 18, 2018; effective December 2, 2018.
Ala. Admin. Code r. 420-3-16-AG Appendix G - Chemical and Bacteriological Tests
I. PRIVATE WATER SUPPLIES AND RECIRCULATED WATER - BACTERIOLOGICAL
Reference: Rules 420-3-16-.08 and 420-3-16-.10(7)(7p)
Application: To private water supplies used by dairy farms, milk plants, frozen dessert plants, receiving stations, transfer stations, and milk tank truck cleaning facilities, and to recirculated cooling water used in dairy processing plants, receiving stations, and dairy farms.
Frequency: Water shall be tested for the presence of total coliform and E. coli initially; after repair, modification, or disinfection of the private water supplies of dairy farms, milk plants, receiving stations, transfer stations, and milk tank truck cleaning facilities, and thereafter; semiannually for all milk plants, receiving stations, transfer stations and milk tank truck cleaning facilities water supplies; and at least every three (3) years on dairy farms. Recirculated cooling water in milk plants, receiving stations, and on dairy farms shall be tested semiannually.
Criteria: An MPN of coliform organisms of less than 1.1 per 100 mL, when ten (10) replicate tubes containing 10 mL, or when five (5) replicate tubes containing 20 mL are tested using the Multiple Tube Fermentation (MTF) technique, or one of the Chromogenic Substrate multiple tube procedures; a direct count of less than 1 per 100 mL using the Membrane Filter (MF) technique; or a presence/absence (P/A) determination indicating less than 1 per 100 mL when one vessel containing 100 mL is tested using the MTF technique or one of the Chromogenic Substrate procedures. The Chromogenic Substrate procedures are not acceptable for recirculated cooling water. Any sample producing a bacteriological result of Too Numerous To Count (TNTC) or Confluent Growth (CG) by the MF technique; or turbidity in a presumptive test with no gas production and with no gas production in confirmation (optional test) by the MTF technique (both MPN and P/A format) shall be considered invalid and shall have a Heterotrophic Plate Count (HPC), from the same sample or subsequent resample, of less than 500 colony forming units (CFU) per mL in order to be deemed satisfactory. Findings by HPC shall be reported as Positive or Not-Found.
Apparatus, Methods, and Procedure - Tests performed shall conform to the current edition of SMEWW or with FDA approved, EPA Promulgated Methods for the Examination of Water and Waste Water or the applicable FDA/NCIMS 2400 Forms (refer to M-a-98, latest revision).
Corrective Action - When the laboratory report on the sample is positive for total coliform but negative for the presence of E. coli or indicates an HPC of greater than 500 CFU per mL on a sample that had previously been invalidated, the water supply in question shall be considered at risk for pathogenic contamination and shall again be physically inspected and necessary corrections made until subsequent samples are bacteriologically satisfactory. This inspection shall be completed within thirty (30) days of the date of the positive test result. If the inspection and corrective action are completed, but the water supply in question is still testing positive for total coliform but negative for E. coli, the facility shall continue to investigate and correct problems until subsequent samples are bacteriologically satisfactory. When the laboratory report on the sample is positive for both total coliform and E. coli, or the facility has failed to complete the water supply inspection within thirty (30) days of the initial positive test result, the water supply is considered unsatisfactory.
II. RECLAIMED WATER AND RECIRCULATED WATER - BACTERIOLOGICAL
Reference - Rules 420-3-16-.07, 420-3-16-.09(08), 420-3-16-.9(20), 420-3-16-.10(7), and 420-3-16-.10(23).
Application - To reclaimed water and recirculated cooling water used in milk plants, receiving stations, transfer stations, and dairy farms.
Frequency – Initially, after repair, modification, or disinfection of the reclaimed water and/or recirculated cooling water supplies of dairy farms, milk plants, receiving stations, and transfer stations; and reclaimed water and recirculated cooling water in milk plants, receiving stations, and on dairy farms shall be tested semiannually thereafter.
Criteria - An MPN of total coliform organisms of less than 1.1 per 100 mL, when ten (10) replicate tubes containing 10 mL, or when five (5) replicate tubes containing 20 mL are tested using the MTF technique, or one (1) of the Chromogenic Substrate multiple tube procedures; a direct count of less than 1 per 100 mL using the MF technique; or a P/A determination indicating less than 1 per 100 mL when one (1) vessel containing 100 mL is tested using the MTF technique or one (1) of the Chromogenic Substrate multiple tube procedures. The Chromogenic Substrate multiple tube procedures are not acceptable for recirculated cooling water. Any sample producing a bacteriological result of TNTC or CG by the MF technique; or turbidity in a presumptive test with no gas production and with no gas production in confirmation (optional test) by the MTF technique (both MPN and P/A format) shall be considered invalid and shall have a HPC from the same sample or subsequent resample of less than 500 CFU per mL in order to be deemed satisfactory. Findings by HPC shall be reported as Positive or Not-Found.
Apparatus, Methods, and Procedure - Tests performed shall conform with the current edition of SMEWW or with FDA approved, EPA promulgated methods for the examination of water and waste water, or the applicable FDA/NCIMS 2400 Forms (refer to M-a-98, latest revision).
Corrective Action - When the laboratory report on the sample is unsatisfactory, the water supply in question shall again be physically inspected and necessary corrections made until subsequent samples are bacteriologically satisfactory.
III. PASTEURIZATION EFFICIENCE-FIELD PHOSPHATASE TEST
Reference - Rule 420-3-16-.10(07)
Frequency - When any laboratory phosphatase test is positive, or any doubt arises as to the adequacy of pasteurization due to noncompliance with equipment, or requirements of 420-3-16-.10(16).
Criteria - Less than 350 mU/L by an electronic phosphatase procedure.
Apparatus - Fluorophos (Advanced Instruments), Paslite and Fast Alkaline Phosphatase (Charm Sciences, Inc.), approved/validated standards and accessories.
Methods - The test is based on the detection of the phosphatase enzyme, a constituent that is inactivated by pasteurization at 63°C (145°F) for thirty (30) minutes or 72°C (161°F) for fifteen (15) seconds. When pasteurization is faulty, some phosphatase remains and is determined by the electronic detection of fluorescent or chemiluminescent by-products of its action on the approved test system’s substrates.
Procedure - Refer to the applicable FDA/NCIMS 2400 Forms and M-a-98, latest revision, for the specific milk and/or milk products for which there are approved phosphatase tests available.
Corrective Action - Whenever a phosphatase test is positive, the cause shall be determined. Where the cause is improper pasteurization, it shall be corrected and any milk or milk products involved shall not be offered for sale.
IV. PHOSPHATASE REACTIVATION IN HTST PASTEURIZED PRODUCTS
The presence of an appreciable quantity of phosphatase in milk and cream after heat treatment has been traditionally regarded as evidence of inadequate pasteurization. However, with the advent of modern HTST methods, evidence has been accumulating that under certain conditions, the relationship between inadequate pasteurization and the presence of phosphatase does not hold.
A number of investigators who have studied HTST pasteurizing methods have concluded that while a negative test can be obtained immediately after pasteurization, the same sample may yield a positive test after a short period of storage, particularly if the product is not continuously or adequately refrigerated. This phenomenon has come to be known as reactivation.
Reactivation may occur in HTST pasteurized products after storage at temperatures as low as 10°C (50°F), although 34°C (93°F) is optimum. Products of high fat content generally produce relatively more reactivable phosphatase.
Reactivation is greatest in products pasteurized at about 110°C (230°F), but may occur in products pasteurized at much higher temperatures and as low as 73°C (163°F).
It has been noted that an increase in holding time during pasteurization will reduce reactivation. The addition of magnesium acetate to HTST processed milk or cream after pasteurization but before storage accelerates reactivation. The difference in activity between an adequately pasteurized sample, stored with and without magnesium, and an inadequately pasteurized sample, stored with and without magnesium, forms the basis of a test for differentiating reactivated from residual, inadequately pasteurized phosphatase.
V. DETECTION OF PESTICIDES IN MILK
Any health agency that has adopted these rules should operate under a control program that will ensure that milk supplies are free from pesticide contamination in conformance with 420-3-16-.03.
Pesticide compounds gain access to milk by various routes, including any of the following:
-
Application to the lactating animals.
-
Inhalation of toxic vapors by the animals, following application to their environment.
-
Ingestion of residues in feed and water.
-
Accidental contamination of milk, feed, and utensils.
At the present time, chlorinated hydrocarbon pesticides are the chief concern. While there are other pest control compounds that are more toxic than the chlorinated hydrocarbons, many of the agents in this latter group tend to accumulate in the body fat of both lactating animals and human beings, and are secreted in the milk of contaminated lactating animals. The accumulation of these toxic agents in a person continually consuming contaminated milk may reach hazardous concentrations. Advances in residue analysis have resulted in a radical decrease in the use of paper chromatographic screening procedures for milk because of its rather limited sensitivity. Health Officers can now routinely detect residues as low as 0.01 ppm of many of the chlorinated organic pesticides. Satisfactory screening procedures should, therefore, attain this level of sensitivity, which usually necessitates the use of gas chromatography or thin layer chromatography.
General screening procedures of the latter two (2) types are described and discussed in Volume 1 of the Pesticide Analytical Manual (PAM) published by FDA.
The need for closer scrutiny of milk supplies for pesticide residues has stimulated considerable research in detection technology. The Health Officer entering upon a surveillance program should carefully check the available equipment in relation to its adaptability to the indicated need. While a schedule of testing comparable to that for microorganisms, four (4) tests of individual producer’s milk during any consecutive six (6) months would be desirable, broad-spectrum procedures are too time consuming to render such a schedule feasible. As a more practical approach, the following procedure is suggested:
-
Test one (1) load of milk from each milk tank truck route every six (6) months by a broad spectrum method and trace positive samples; or
-
Test each producer's milk four (4) times every six (6) months for the most common chlorinated hydrocarbon pesticides by available instrumental methodology.
Note: Where Procedure 1 is used, samples of commingled milk from known sources are drawn from receiving station storage tanks. Sampling for Procedure 2 may be done directly from the weigh tank.
VI. DETECTION OF DRUG RESIDUES IN MILK
The problem of drug residues in milk is associated with their use in the treatment of mastitis and other diseases. Failure to withhold milk from the market for a sufficient length of time after treatment may result in the presence of drug residues in milk. Such milk is undesirable for two (2) reasons:
-
It comes from an unhealthy lactating animal.
-
It is adulterated.
The allergenic properties of certain drugs in common use make their presence in milk potentially hazardous to consumers. Also, substantial losses of by products may be sustained by the milk industry each year because of the inhibitory effects of drug residues on the culturing process. Drug residues shall be tested for, using tests provided for in 420-3-16-.07. These tests are specified in memoranda from the FDA (refer to the latest revision of M-a-85 for the approved drug tests, the FDA/NCIMS 2400 Forms for each specific test method and M-a-98, latest revision, for the specific milk and/or milk products for which there are approved drug tests available).
VII. ANALYSIS OF MILK AND MILK PRODUCTS FOR VITAMIN A AND D CONTENT
Reference - Rule 420-3-16-.07
Frequency - Annually for each product type, or when any doubt arises as to the adequacy of vitamin fortification (refer to Appendix O).
Methods - Vitamin testing shall be performed using test methods acceptable to the FDA and other official methodologies that give statistically equivalent results to the FDA methods (refer to M- a-98, latest revision, for the specific milk and/or milk products that have FDA validated and NCIMS accepted test methods for vitamins).
REFERENCES
Official Methods of Analysis of AOAC INTERNATIONAL, 19th Edition, 2012.
Pesticide Analytical Manual, (PAM) available from the U. S. Food and Drug Administration, Center for Food Safety and Applied Nutrition, HFS-335, 5100 Paint Branch Parkway, College Park, MD 20740-3835.
History
- Author: G. M. Gallaspy, Jr.
- Authority: Code of Ala. 1975, §§22-2-2, 22-20-7.
- Repealed and New Rule: Filed October 18, 2018; effective December 2, 2018.
Ala. Admin. Code r. 420-3-16-AH Appendix H - Pasteurization Equipment and Procedures and Other Equipment
I. HIGH TEMPERATURE/SHORT TIME (HTST) PASTEURIZATION OPERATION OF HTST PASTEURIZATION SYSTEMS
HTST pasteurization is important to the dairy industry because of the operating efficiencies that it affords. Properly operated, these units allow a high volume of production in a minimum of processing space.
The ability of HTST pasteurizers to assure a safe, finished milk and/or milk product hinges on the reliability of the time-temperature-pressure relationships that must prevail whenever the system is in operation. It is important that the milk plant operator understand the HTST process in order to maintain proper surveillance over the equipment. The basic flow pattern is described below:
- Cold raw milk or milk product in a constant-level supply tank is drawn into the regenerator section of the HTST pasteurizer.
Note: Some operators prefer to bypass the regenerator when starting. Under this system, cold milk is drawn directly through the timing pump, step 3, and into the heater section. The remaining steps are performed without exception. This bypass arrangement facilitates and speeds up the starting operation. After forward-flow has been established at the FDD, the bypass, which may be manually or automatically controlled, is not used and the raw milk or milk product flows through the regenerator. A second start-up technique involves the use of sanitizing solution at 77°C (170°F). This is passed through the complete unit and followed immediately by milk or milk product. Dilution of the first milk or milk product does occur; however, care shall be taken to prevent this from being packaged.
-
In the regenerator section, the cold raw milk or milk product is warmed by hot pasteurized milk or milk product flowing in a counter current direction on the opposite sides of thin stainless steel surfaces.
-
The raw milk or milk product still under suction passes through a positive-displacement-timing pump that delivers it under pressure through the rest of the HTST pasteurization system.
-
The raw milk or milk product is pumped through the heater section where hot water or steam on opposite sides of thin stainless steel surfaces heats the milk or milk product to a temperature of at 72°C (161°F).
-
The milk or milk product at pasteurization temperature and under pressure flows through the holding tube where it is held for at least fifteen (15) seconds. The maximum velocity of the milk or milk product through the holding tube is governed by the speed of the timing pump, the diameter and length of the holding tube, and surface friction.
-
After passing the sensing bulbs of the indicating thermometer and recorder/controller, the milk or milk product passes into the FDD which automatically assumes a forward-flow position if the milk or milk product passes the recorder/controller bulb at the preset cut-in temperature, i.e., 72°C (161°F).
-
Improperly heated milk or milk product flows through the diverted-flow line back to the constant-level tank.
-
Properly heated milk or milk product flows through the forward-flow line to the pasteurized milk or milk product regenerator section where it serves to warm the cold raw milk or milk product and, in turn, is cooled.
-
The warm milk or milk product passes through the cooling section where coolant on the sides of thin stainless steel surfaces opposite the pasteurized milk or milk product reduces its temperature to 4.5°C (40°F) and below.
-
The cold pasteurized milk or milk product then passes to a storage tank or vat to await packaging.
HTST PASTEURIZERS EMPLOYING MILK OR MILK PRODUCT-TO-MILK OR MILK PRODUCT REGENERATORS WITH BOTH SIDES CLOSED TO THE ATMOSPHERE
Rule 420-3-16-.10(16) establishes standards for regenerators. These standards ensure that the raw milk or milk product will always be under less pressure than pasteurized milk or milk product in order to prevent contamination of the pasteurized milk or milk product in the event flaws should develop in the metal or joints separating it from the raw milk or milk product. An explanation of regenerator specifications is given below.
During normal operation, i.e., while the timing pump is operating, raw milk or milk product will be drawn through the regenerator at sub-atmospheric pressure. The pasteurized milk or milk product in the milk, or milk product-to-milk or milk product regenerator will be above atmospheric pressure. The required pressure differential will be assured when there is no flow-promoting device downstream from the pasteurized milk or milk product side of the regenerator to draw the pasteurized milk or milk product through the regenerator, and the pasteurized milk or milk product downstream from the regenerator rises to at least 30.5 centimeters (twelve [12] inches) elevation above the highest raw milk or milk product level downstream from the constant-level tank, and is open to the atmosphere at this or a higher elevation, as required in Item 16p(C), 420-3-16-.10(16)(iv) (refer to Administrative Procedures 2).
During a shutdown, i.e., when the timing pump stops, the raw milk or milk product in the regenerator will be retained under suction, except this suction may be gradually relieved by possible entrance of air drawn through the regenerator plate gaskets from the higher outside atmospheric pressure. With a free draining regenerator as required under Item 16p(C), Administrative Procedures 8, the raw milk or milk product level in the regenerator may drop slowly depending on the tightness of the gaskets ultimately falling below the level of the plates to the milk or milk product level in the constant-level tank. However, under these conditions, as long as any raw milk or milk product remains in the regenerator, it will be at sub-atmospheric pressure.
During shutdown, the pasteurized milk or milk product in the regenerator is maintained at atmospheric pressure or above by meeting the elevation requirement of Item 16p(C), (refer to Administrative Procedures 2). Pressure greater than atmospheric is maintained when the level of pasteurized milk or milk product is at or above the required elevation and loss of pressure due to suction is prevented by prohibiting a downstream pump.
Any backflow of milk or milk product through the FDD would lower the pasteurized milk or milk product level during pump shutdowns thus tending to reduce the pressure on the pasteurized milk or milk product side of the regenerator. An FDD cannot be relied upon to prevent backflow in such instances because during the first few minutes following a pump shutdown, the milk or milk product is still at a sufficiently high temperature to keep the FDD in the forward flow position. Compliance with the provisions of Item 16p(C), Administrative Procedures 2 and 3; however, will ensure a proper pressure differential in the regenerator.
At the beginning of a run, from the time raw milk or milk product or water is drawn through the regenerator until the pasteurized milk or milk product or water has risen to the elevation specified in Item 16p(C), Administrative Procedures 2, the pasteurized milk or milk product side of the regenerator is at atmospheric pressure or higher. Even if the timing pump should stop during this period, the pressure on the pasteurized milk or milk product side of the regenerator will be greater than the sub-atmospheric pressure on the raw milk or milk product side. This will be assured by compliance with Item 16p(C), Administrative Procedures 2 and 3, as long as any raw milk or milk product remains in the regenerator.
When a raw milk or milk product booster pump is incorporated into the HTST pasteurization system, Item 16p(C), Administrative Procedures 5 requires, in part, that automatic means shall be provided to assure, at all times, the required pressure differential between raw and pasteurized milk or milk product in the regenerator before the booster pump can operate.
THE USE OF SEPARATORS WITHIN HTST SYSTEMS
Separators in HTST pasteurization systems shall be installed and operated in such a manner that they will not adversely affect the regenerator pressures, create a negative pressure on the FDD during operation, or cause milk or milk product flow through the holding tube during times when such flow would compromise a required public health safe guard.
- A separator may be located between the outlet of a raw regenerator and the timing pump or between raw regenerator sections if the separator is automatically valved-out of the system, and separator stuffing pump(s) are de-energized, when:
a. The timing pump is not in operation; or
b. A dual stem FDD is in the inspect position; or
c. In a system with a dual stem FDD in which the separator is located between sections of a raw regenerator, during the first ten (10) minutes of a required ten (10) minute time delay in CIP mode and during any period of diverted-flow; or
d. The pressures in any raw regenerator sections located after the separator are out of compliance with the pressure requirements of these rules.
Note: The second section of a split raw regenerator shall automatically drain freely to the constant-level tank or to the floor in the event of a shut down.
-
A separator may not be located between the timing pump and the FDD.
-
A separator may be located on the pasteurized side of the FDD if:
a. A properly installed atmospheric break is located between the FDD and the inlet of the separator.
b. All milk or milk product rises to at least 30.5 centimeters (twelve [12] inches) higher than the highest raw milk or milk product in the system and is open to the atmosphere at some point between the outlet of the separator and the inlet of any pasteurized side regenerator.
c. All milk or milk product rises to at least 30.5 centimeters (twelve [12] inches) higher than the highest raw milk or milk product in the system and is open to the atmosphere at some point between the outlet of any pasteurized side regenerator and the inlet of a separator.
d. The separator is automatically valved-out of the system, and the separator stuffing pump is de-energized.
(1) When a dual stem FDD is in the first ten (10) minutes of a required ten (10) minute delay in CIP mode.
(2) When the FDD is diverted in product or inspect mode.
(3) When the timing pump is not in operation.
(4) When the temperature is below the required pasteurization temperature and the FDD is not in the fully diverted-position.
- The following criteria apply to installations where a separator shall be valved-out:
a. A valve shall be located to isolate the product supply line from the separator.
b. A valve shall be located to prevent all flow exiting the separator from being returned to the pasteurization system downstream of the separator.
c. The valves are required to move in order to accomplish the two (2) criteria listed above and shall move to the valved-out position, and any separator stuffing pumps shall be de-energized upon loss of air or power.
- The following criteria applies to installations where a separator is located on the raw side of a HTST system and a cream or skim balance tank(s) is not being utilized for the collection of either the cream or skim that exits the HTST system:
a. A fail-safe (spring-to-close upon loss of air or power), block-and-bleed valve or valve arrangement shall be installed on the cream or skim line downstream from the separator and prior to any pump(s) or cream or skim storage tank(s), and shall be at least 30.5 centimeters (12 inches) below the required opening to the atmosphere on the pasteurized side of the HTST regenerator. This fail-safe valve or valve arrangement shall be closed whenever the separator is required to be automatically valved-out of the system and the separator stuffer pump is de-energized.
b. If a computer or programmable controller is used to provide any of these required functions, it shall comply with the applicable Section(s) of Appendix H, VI.
c. If not installed in compliance with a. and b. above, the height of the cream or skim storage tank shall be considered when determining the highest raw product in the HTST system.
THE USE OF LIQUID INGREDIENT INJECTION WITHIN HTST SYSTEMS
Milk or milk product flavoring slurries, condensed milk or milk products, and cream or skim milk for standardization and similar ingredients may be injected at a point after the last regenerator and before the timing pump, if all of the following conditions are met:
- The slurry injection valve(s) is (are) closed and the slurry pump is de-energized:
a. When the FDD is in the “Inspect” mode.
b. When the timing pump is not in operation.
c. When the temperature is below the required minimum legal pasteurization temperature and the FDD is not in the fully diverted position.
Note: The slurry pump may remain energized provided:
(1) A spring-to-close and air-to-open blocking valve is located between the slurry injection pump and the slurry injection valve(s) described in 2 below.
(2) All valves shall be inter-wired to assure they fully isolate the slurry pump from the pasteurization system when the FDD is not in the forward-flow position or whenever any flow-promoting device(s) which is (are) upstream of the FDD and (are) capable of generating flow through the FDD is (are) not in operation.
-
The slurry injection valve(s) is (are) of the fail-safe type, spring-to-close and air-to-open, and are “block-and-bleed” design with a full port open to the atmosphere between the HTST isolation seat and the slurry pump when slurry is not being injected.
-
The slurry piping between the slurry pump and the injection point may rise to a height that is higher than the overflow level of the slurry supply tank(s), but is at least 30.5 centimeters (twelve [12] inches) lower than the required opening to the atmosphere on the pasteurized side.
-
The slurry supply tank has an overflow that is at least twice the diameter of the largest inlet pipe, or all inlet pipes are disconnected and the openings capped during operation of the slurry pump.
-
There is a check-valve in the flow stream of the milk or milk product line from the last regenerator, typically after the separator, upstream of the injection point valve.
-
For a milk or milk product flavoring slurry that contains milk and/or milk products, the tanks and/or vessels used to blend and hold the slurry shall be completely emptied and cleaned after each four (4) hours of operation or less, unless the slurry is stored at a temperature of 7°C (45°F) or less, or at a temperature of 66°C (150°F) or greater, and maintained thereat until the time of injection.
-
If computers or programmable controllers are used to provide any of these required functions, they shall meet the applicable portion of Appendix H, VI.
-
Appropriate test procedures shall be provided to evaluate the required inter-wiring and function.
Note: This section describes one (1) method that has been reviewed and accepted for this purpose. It does not preclude other methods that may be reviewed and found acceptable.
In order to help assure compliance with Section 2-Adulteration, the Health Officer may require that the milk plant close the slurry valve and de-energize the slurry pump during times when the system is recycling milk or milk product, such as in recycle mode, diverted-flow, or the first ten (10) minutes of the CIP cycle. If a computer is used to accomplish this, it does not need to meet Appendix H and VI.
PRESSURE RELIEF VALVES LOCATED DOWNSTREAM FROM THE HOLDING TUBE WITHIN HTST PASTEURIZATION SYSTEMS
The pressures in the pasteurized side of the regenerator shall be protected from falling within 6.9 kPa (1 psi) of the pressures in the raw side of the regenerator at all times, including during shut down. A pressure relief valve on the pasteurized side of the FDD will meet this criterion if the pressure relief valve is fail-safe. A leaking pressure relief valve can cause an unacceptable loss of pressure in the pasteurized side of the regenerator during a shut down and is considered a violation of Item 16p(C) 420-3-16-.10(19). Any leakage from this pressure relief valve shall be readily visible. This may be accomplished by opening the pressure relief valve vent directly to the floor or by providing sanitary piping from the pressure relief valve vent to the constant-level tank. If the latter option is utilized, the piping shall be properly sloped to assure drainage to the constant-level tank and shall be provided with a properly located and installed sight-glass.
POSITION DETECTION DEVICES
Where the position detectability of FDDs and valve seats is required this may be accomplished by mechanical or electronic means, such as mechanical limit switches (micro-switches) or electronic proximity switches. These switches shall be capable of providing an electrical signal when the valve seat is in the fully closed position, provided further that the position detection capability is fully testable.
Position detection devices (PDDs) shall be repeatable and capable of detecting valve seat movement of less than 3.18 mm (1/8 [0.125] of an inch) at all times.
MAGNETIC FLOW METER BASED TIMING SYSTEMS WITHIN CONTINUOUS FLOW PASTEURIZATION SYSTEMS
Many pasteurization systems use magnetic flow meter based timing systems (MFMBTS). The flow through these timing systems is developed by a combination of flow promoting devices including booster and stuffer pumps, separators and clarifiers, homogenizers, and positive displacement pumps.
Item 16p.(B)2(f), Section 7 provides for their use, provided they meet the following specifications for design, installation, and use.
Components - MFMBTS shall consist of the following components:
A magnetic flow meter which has been reviewed by FDA or one (1) which meets the following criteria for accuracy and reliability:
a. Self-diagnostic circuitry that provides constant monitoring of all sensing, input, and conditioning circuits. The diagnostic circuitry shall be capable of detecting “open” circuits, “short” circuits, poor connections, and faulty components. Upon the detection of a failure of any component, the magnetic flow meter read-out shall be blank or become unreadable.
b. The electro-magnetic compatibility of the magnetic flow meter shall be documented and available to the Health Officer. The magnetic flow meter shall be tested to determine the effects of electrostatic discharge, power fluctuation, conductive emission and susceptibility, and radiative emission and susceptibility.
c. The effect of exposure to specific environmental conditions shall be documented. The magnetic flow meter shall be tested to determine the effects of low and high temperatures, thermal shock, humidity, physical shock, and salt fog.
d. The magnetic flow meter converter or transmitter and flow sensor, for those magnetic flow meters in which flow sensor sealing is required, shall be constructed so that they can be sealed by the Health Officer.
e. The calibration of the magnetic flow meter shall be protected against unauthorized changes.
f. The magnetic flow meter shall be protected against unauthorized converter or transmitter replacement. If flow tubes are replaced, the Health Officer shall be notified and such replacement shall be regarded as a replacement of the magnetic flow meter and subject to the Health Officer’s inspection and all applicable tests under Appendix I.
g. The flow tube shall be encased in appropriate material and constructed in such a manner that the final assembly complies with the conditions cited within Item 11p 420-3-16-.10(11).
Calibration - The calibration shall be based on multiple points for the entire range of the magnetic flow meter for MFMBTS application. The magnetic flow meter shall be tested against a traceable National Institute of Standards and Technology (NIST) standard. The procedure(s) used for the magnetic flow meter calibration is documented and available to the Health Officer.
Accuracy - At mid-range, six (6) consecutive flow measurements are taken at the same flow setting. From these six (6) measurements, the standard deviation is calculated. The standard deviation for these measurements shall be less than 0.5 percent. Compliance of the determined through the actual installation field-testing of the magnetic flow meter.
-
Suitable converters for conversion of electric and/or air signals to the proper mode for the operation of the system.
-
A suitable flow recorder capable of recording flow at the flow alarm set point and also at least nineteen (19) liters (five [5] gallons) per minute higher than the flow alarm setting. The flow recorder shall have an event pen that shall indicate the status of the flow alarm with respect to flow rate.
-
A flow alarm, with an adjustable set point shall be installed within the system which shall automatically cause the FDD to be moved to the divert position whenever excessive flow rate causes the milk or milk product holding time to be less than the legal holding time for the pasteurization process being used. The flow alarm shall be tested by the Health Officer in accordance with the procedures of Appendix I, Test 11, 2.A and B at the frequency specified. The flow alarm adjustment shall be sealed.
Note: Test 11, 2.A is not applicable to HHST pasteurization systems.
-
A low-flow or loss-of-signal alarm shall be installed with the system, which shall automatically cause the FDD to be moved to the divert position whenever there is a low-flow or loss-of-signal from the magnetic flow meter. The low-flow or loss-of-signal provision shall be tested by the Health Officer in accordance with Appendix I, Test 11, 2.C at the frequency specified. The low-flow or loss-of-signal provision shall be sealed.
-
For HTST systems, when the legal flow rate has been reestablished following an excessive flow rate, a time delay shall be instituted which shall prevent the FDD from assuming the forward-flow position for at least a minimum of fifteen (15) or twenty-five (25) seconds depending upon the product being pasteurized and the temperature being utilized. The time delay shall be tested and sealed by the Health Officer.
For HHST systems, when the legal holding time has been reestablished following an excessive flow rate, a time delay at least as long as the legal flow rate shall be instituted which shall prevent the FDD from assuming the forward-flow position until at least the legal holding time within the holding tube has been reestablished. This time delay shall be built into the sequencelogic that requires all conditions for legal pasteurization to be satisfied and that legal pasteurization temperature exists from the holding tube to the FDD, before the FDD can assume the forward-flow position.
- For HTST systems, a sanitary check valve or normally closed automatically controlled sanitary valve shall be installed with the magnetic flow meter to prevent a positive pressure in the raw milk or milk product side of the regenerator whenever a power failure, shutdown, or flow-diversion occurs.
Note: This provision is not applicable to HHST pasteurization systems.
- For HTST systems, when a regenerator is used with large systems, it will be necessary to bypass the regenerator during start-up and when the FDD is in the diverted-flow position. Care shall be taken in the design of such bypass systems to assure that a dead-end does not exist. A dead-end could allow milk or milk product to remain at ambient temperature for long periods of time and allow bacterial growth in the milk or milk product. Caution shall also be observed with such bypass systems and any valves used in them so that raw milk or milk product will not be trapped under pressure in the raw regenerator plates and not have free drainage back to the constant-level tank when shutdown occurs.
Note: This provision is not applicable to HHST pasteurization systems.
-
When switching to the “CIP” position, the FDD shall move to the divert position and shall remain in the diverted-flow position for at least ten (10) minutes, regardless of temperature, and for HTST pasteurization systems, the booster pump cannot run during this ten (10) minute time delay.
-
All MFMBTS pasteurization systems shall be designed, installed, and operated so that all applicable tests required by 420-3-16-.10(21), Item 16p(D) can be performed by the Health Officer, at the frequency specified (refer to Appendix I). Where adjustment or changes can be made to these devices or controls, appropriate seals shall be applied by the Health Officer after testing so that changes cannot be made without detection.
-
Except for those requirements directly related to the physical presence of the timing pump, all other requirements of the most recent edition of these rules are applicable.
Placement of Components - Individual components in an MFMBTS shall comply with the following placement conditions:
-
The timing system’s flow promoting device(s) shall be located upstream from the magnetic flow meter.
-
The magnetic flow meter shall be placed after the last raw product regenerator outlet and upstream of the holding tube. There shall be no intervening flow-promoting components between the magnetic flow meter and the holding tube.
-
For HTST pasteurization systems, when a sanitary check valve or normally closed automatically controlled sanitary valve, as described in #7 above, is used with a variable or constant speed flow promoting device, it shall be located downstream of the last regenerator outlet and upstream of the holding tube.
Note: This provision is not applicable to HHST pasteurization systems.
-
All flow-promoting devices which are upstream of the FDD and which are capable of generating flow through the FDD, shall be properly interwired with the FDD so that they may run and produce flow through the system at sub-legal temperatures only when the FDD is in the fully diverted position and in “Product” run mode, or “CIP” mode after the ten (10) minute time delay has timed out. Such flow promoting devices shall be de-energized in “Inspect” mode. Separators or clarifiers that continue to run after they are de-energized shall be automatically valved-out of the system with fail-safe valves so that they are incapable of producing flow.
-
There shall not be any product entering or leaving the pasteurization system, i.e., cream or skim milk from a separator or other product components, between the magnetic flow meter and the holding tube.
-
The magnetic flow meter shall be so installed that the milk or milk product has contact with both electrodes at all times when there is flow through the system. This is most easily accomplished by mounting the flow tube of the magnetic flow meter in a vertical position with the direction of flow from the bottom to the top. However, horizontal mounting is acceptable when other precautions are taken to assure that both electrodes are in contact with the product and the horizontal line shall remain full of liquid during operation. Magnetic flow meters shall not be mounted on a horizontal line that may be only partially full and thereby trap air.
-
The magnetic flow meter shall be piped in such a manner that at least ten (10) pipe diameters of straight pipe exists, upstream and downstream from the center of the magnetic flow meter, before any elbow or change of direction takes place. Except that other piping configurations upstream and downstream of the magnetic flow meter may also be used if they have been reviewed and found acceptable to FDA and the Health Officer.
THE USE OF VACUUM BREAKERS ON HTST SYSTEMS
Vacuum breakers are often used on HTST pasteurization systems to help maintain proper pressure relationships in milk-to-milk regenerator sections, or to prevent a negative pressure between the FDD and any downstream flow-promoting device. The use of vacuum breakers on HTST pasteurization systems is allowed provided the following conditions are met:
-
Vacuum breakers shall open to the atmosphere when subject to a negative pressure.
-
The pasteurized milk and milk product between its outlet from the regenerator and the nearest point downstream open to the atmosphere shall rise to a vertical elevation of 30.5 centimeters (12 inches) above the highest raw milk or milk product level, downstream from the constant- level tank, and shall be open to the atmosphere at this or a higher elevation.
Spring-to-close vacuum breakers are not allowed.
HTST AND HHST FLOW DIAGRAMS
Figure 31. HTST Pasteurizer with a Positive Displacement Rotary Timing Pump
Figure 32. HTST Pasteurizer with a Homogenizer Located at the Outlet of the Heater Section and of a Larger Capacity than the Timing Pump
Figure 33. HTST Pasteurizer with a Booster Pump, Meter Based Timing System and a Homogenizer with a Bypass Line
Figure 34. HTST Pasteurizer with a Booster Pump, Timing Pump, and a CIP-Type Separator Located Between Two Pasteurized Product Regenerators with a Pre-Heater
Figure 35. HTST Pasteurizer with a Booster Pump, Homogenizer as a Timing Pump with an AC Variable Frequency Drive, CIP-Type Separator Located Between Two Pasteurized Product Regenerators and an Air Actuated Discharge Valve with an Air Blow
Figure 36. HTST Pasteurizer with a Separator Between the Raw Regenerator and the Heater Section with a Meter Based Timing System and a Regenerator Bypass
Figure 37. HTST Pasteurizer Utilizing Tubular Type Heat Exchangers and a Homogenizer as the Timing Pump
Figure 38. HTST Pasteurizer, without a Regenerator or Cooler Section, with a Meter Based Timing System Located Upstream from an Evaporator
Figure 39. HTST Pasteurizer with a Regenerator, Separator, Skim Surge Tank, and a Meter Based Timing System Located Upstream from an Evaporator Pump
Figure 40. HHST Pasteurizer with a Flow-Diversion Device Located Downstream of the Cooling Section
Figure 41. HHST Pasteurizer Utilizing Steam Injection Heating, Vacuum Flash Cooling, and a Flow-Diversion Device Located Downstream of the Cooler Section Pump
Figure 42. HHST Pasteurizer Utilizing Direct Culinary Steam Infusion and Vacuum Flash Cooling with a Homogenizer Located Downstream
Figure 43. HHST Pasteurizer with a Homogenizer as the Timing Pump and Utilizing a Spiral Tubular Heat Exchanger with Indirect Regeneration
II. AIR FOR DRYING EQUIPMENT AND AIR UNDER PRESSURE - DIRECT CONTACT WITH MILK AND MILK PRODUCTS AND MILK PRODUCT-CONTACT SURFACES
AIR FOR DRYING EQUIPMENT
Filter Media - Intake air filter media shall consist of fiberglass with a downstream backing dense enough to prevent fiberglass break off from passing through cotton flannel, wool flannel, spun metal, activated carbon, activated alumina, non-woven fabric, absorbent cotton fiber, electrostatic, or other suitable materials which, under conditions of intended use, are non-toxic and non-shedding and which do not release toxic volatiles or other contaminants to the air, or volatiles which impart any flavor or odor to the milk or milk product. Chemical bonding materials contained in the media shall be non-toxic, non-volatile, and insoluble under all conditions of use. Disposable media are not intended to be cleaned and re-used. Electronic air cleaners using electrostatic precipitation principles to collect particulate matter may be used in spray drying systems only as a pre-filter.
Filter Performance - The air supply system and/or ducting shall be such that the air supply is caused to pass through suitable air filters, properly installed, before coming in contact with milk product-contact surfaces of the drying system. Supply air filters for air which will be heated before it comes in contact with the milk or milk product shall be of a design selected to operate at a face velocity, and installed in a manner which will allow the filter manufacturer's rating to be 90 percent or higher, when tested in accordance with the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) Synthetic Dust Arrestance Test.1 Supply air filters for air which will not be heated before it comes in contact with the milk or milk product shall be of a design selected to operate at a face velocity, and installed in a manner which will allow the filter manufacturer's rating to be 85 percent or higher when tested in accordance with the ASHRAE Atmospheric Dust Spot Method.2
AIR UNDER PRESSURE - MILK PRODUCT-CONTACT SURFACES
Filter Media - Air intake and pipeline filters shall consist of fiberglass with a downstream backing dense enough to prevent fiberglass break off from passing through cotton flannel, wool flannel, spun metal, electrostatic material or other equally acceptable filtering media which are non-shedding and which do not release to the air, toxic volatiles or volatiles which may impart any flavor or odor to the milk or milk product.
Filter Performance - Intake air filter efficiency shall be at least 98 percent SAE J7263, June 19874 using Air Cleaner (AC) coarse test dust. Final filter efficiency shall be at least 99 percent as measured by the Dioctylphthalate Fog Method (DOP) test (with a mean particle diameter of 0.3 microns).5 When commercially sterile air is required, the final filter efficiency shall be at least 99.99 percent as measured by the DOP test.
__________________________________________ 1 Method of Testing Air Cleaning Devices, ASHRAE Standard 52 (available from the American Society of Heating, Refrigerating and Air Conditioning Engineers 2Method of Testing Air Cleaning Devices, ASHRAE Standard 52 (available from the American Society of Heating, Refrigerating and Air Conditioning Engineers 3 Dill, R. S., A Test Method for Air Filters. Transactions of the American Society of Heating and Ventilation engineers. 44:379, 1938. Society of Automotive Engineers, 400 Commonwealth Drive, Warrendale, Pennsylvania 15096-0001 (412) 776-4841. 4 DOP Smoke Penetration and Air Resistance of filters. Military Standard No. 282. Section 102.91. Naval Supply Depot, 5801 Tabor Avenue, Philadelphia, Pennsylvania 19120. 5 MIL-STD-282-Military Standard 282: Method 102.91: Dicoctyphthalate Fog Method (DOP). Standardization, Document Order Desk (Department of Navy), 700 Robinson Avenue, Building 4, Section D. Philadelphia, PA 1911-5094.
FABRICATION AND INSTALLATION Air Supply Equipment - The compressing equipment shall be designed to preclude contamination of the air with lubricant vapors and fumes. Oil-free air may be produced by one of the following methods or their equivalent:
a. Use of a carbon ring piston compressor;
b. Use of oil-lubricated compressor with effective provision for removal of any oil vapor by cooling the compressed air; or
c. Water-lubricated or non-lubricated blowers.
The air supply shall be taken from a clean space or from relatively clean outer air and shall pass through a filter upstream from the compressing equipment. This filter shall be located and constructed so that it is easily accessible for examination and the filter media are easily removable for cleaning or replacing. The filter shall be protected from weather, drainage, water, product spillage, and physical damage.
Moisture Removal Equipment - Air under pressure systems in excess of one (1) bar, i.e., 103.5 kPa (15psi), shall be provided with methods of moisture removal. The removal of moisture may be achieved by condensation and coalescing filtration or absorption, or equivalent, to prevent free water in the system. If it is necessary to cool the compressed air, an after-cooler shall be installed between the compressor and the air storage tank for the purpose of removing moisture from the compressed air.
Filters and Moisture Traps - Filters shall be constructed so as to assure effective passage of air through the filter media only. The coalescing filter and associated traps shall be located in the air pipeline downstream from the compressing equipment, and from the air tank, if one is used. The filter shall be readily accessible for examination, cleaning, and for replacing the filter media. The moisture trap shall be equipped with a petcock or other means for draining accumulated water (refer to Figures 44, 45, and 48).
When coalescing filters are used, a means shall be provided to measure the differential pressure across the filter. The differential pressure device is required to indicate the need for filter media replacement.
All coalescing filter housings shall be provided with a means of removing the condensed liquid from the filtration device. This can be accomplished by an automatic or manual drain installed on the base of the filter housing.
The final filter media shall be disposable. The filter media shall be located in the air line upstream from, and as close as possible to, the point of application (refer to Figures 44, 45 and 48). Except that a final filter shall not be required where the compressing equipment is of a fan or blower type and operating at a pressure of less than one (1) bar, i.e., 103.5 kPa (15psi) (refer to Figures 46 and 47).
Electronic air cleaners utilizing electrostatic precipitation principles to collect particulate matter may be used. Disposable filter media shall not be cleaned and reused.
Air Piping - The air piping from the compressing equipment to the filter and moisture trap shall be readily drainable.
A milk or milk product check-valve of sanitary design shall be installed in the air piping downstream from the disposable media filter to prevent backflow of milk or milk product into the air pipeline, except that a check-valve shall not be required if the air piping enters the milk or milk product zone from a point higher than the milk or milk product overflow level which is open to the atmosphere or is for dry product applications or for other dry application where liquids are not present.
When a check-valve is not required, plastic or rubber or rubber-like tubing and suitable compatible fittings and connections made of plastic or stainless steel may be used between the final filter and the point of application.
Air distribution piping and fittings after the final filter shall be of corrosion-resistant materials. Air distribution piping, fittings, and gaskets between the discharge of the sanitary check-valve to the processing equipment shall be sanitary piping that conforms to the requirements of Item 10p, Rule 420-3-16-.10(10), except that:
When air under pressure is directed at product-contact surfaces of containers, closures, and supplementary fitments, the air passage from the final filter to the point of application shall be made of a non-toxic, relatively nonabsorbent material. In this application, check-valves are not
required. The final filter shall be located as close as practical to the point of application (refer to Figure 48).
When used for air agitation, tubing used to introduce air into the product and/or product zone shall be sanitary piping that conforms to the requirements of Item 10p, Rule 420-3-16-.10(10). There shall be no threads on product-contact surfaces. When drilled or perforated pipe is used, internal drilling burrs shall be removed and the orifices shall be chambered on the outer surface of the pipe. If the volume of the air from the compressing equipment is in excess of that required for satisfactory agitation, suitable means shall be employed to eliminate the excess volume.
Note: For additional details, refer to the 3-A Accepted Practices for Supplying Air Under Pressure in Contact with Milk, Milk Products and Product-Contact Surfaces 604-## and 3-A Accepted Practices for Spray Drying Systems 607##.
Figure 44. Individual Compression-Type Air Supply
| 1. Compressing Equipment | 7. Final Filter | | --- | --- | | 2. Drain Valve | 8. Product Contact Valve (Where Required) | | 3. After-cooler (When Used) | 9. Sanitary Piping Downstream From This Point | | 4. Pressure Gauge (Optional) | 10. To Point of Application | | 5. Dryer (When Used) | 11. Intake Air Filter | | 6. Air Pipe Line Coalescing Filter and Moisture Trap | |
Figure 45. Central Compression-Type Air Supply
| 1. Compressing Equipment | 10. Final Filter | | --- | --- | | 2. Intake Air Filter | 11. To Point of Application | | 3. After-cooler | 12. Drain Valve | | 4. Sanitary Relief Valve | 13. Moisture Leg or Trap | | 5. Air Pipe Line Coalescing Filter and | 14. Air Storage Tan | | 6. Moisture Trap Pressure Gauge (Optional) | 15. Air Gap | | 7. Dryer (When Used) | 16. Trap and Drain Valve | | 8. Sanitary Piping Downstream From This Point | 17. Condensate Pip | | 9. Product Check-Valve (Where Required) | |
Figure 46. Individual Blower-Type Air Supply
| 1. Blower or Fan, 34.5-103.5 kPa (5-15 psi) | 4. To Point of Application | | --- | --- | | 2. Air Line or Duct | 5. Final Filter (When Used) | | 3. Pressure Gauge (When Used) | 6. Intake Air Filter |
Figure 47. Individual Fan-Type Air Supply
- Blower or Fan, Below 34.5 kPa (5 psi)
- Intake Air Filter
- To Point of Application
Figure 48. Rotating Mandrel Assembly
| 1. Compressing Equipment | 6. Dryer (When Used | | --- | --- | | 2. After-cooler (When Used | 7. Final Filter | | 3. Pressure Gauge (When Used | 8. Intake Air Filter | | 4. Air Pipeline Coalescing Filter and Moisture Trap | 9. Fixed Air Passage | | 5. Drain Valve | 10. Rotating Mandrel Assembly |
III. CULINARY STEAM – MILK AND MILK PRODUCTS
The following methods and procedures will provide steam of culinary quality for use in the processing of milk and milk products.
SOURCE OF BOILER FEED WATER
Potable water or water supplies acceptable to the Health Officer shall be used.
FEED WATER TREATMENT
Feed water may be treated, if necessary, for proper boiler care and operation. Boiler feed water treatment and control shall be under the supervision of trained personnel or a firm specializing in industrial water conditioning. Such personnel shall be informed that the steam is to be used for culinary purposes. Pretreatment of feed waters for boilers or steam generating systems to reduce water hardness before entering the boiler or steam generator by ion exchange or other acceptable procedures is preferable to the addition of conditioning compounds to boiler waters. Only compounds complying with 21 CFR 173.310 may be used to prevent corrosion and scale in boilers or to facilitate sludge removal. Greater amounts shall not be used of the boiler water treatment compounds than the minimum necessary for controlling boiler scale or other boiler water treatment purposes. No greater amount of steam shall be used for the treatment and/or pasteurization of milk and milk products than necessary.
It should be noted that tannin, which is also frequently added to boiler water to facilitate sludge removal during boiler blow-down, has been reported to give rise to odor problems and should be used with caution.
Boiler compounds containing cyclohexylmine, morpholine, octadecylamine, diethylamino-ethanol, trisodium nitrilotriacetae, and hydrazine shall not be permitted for use in steam in contact with milk and milk products.
BOILER OPERATION
A supply of clean, dry saturated steam is necessary for proper equipment operation. Boilers and steam generation equipment shall be operated in such a manner as to prevent foaming, priming, carryover, and excessive entrainment of boiler water into the steam. Carryover of boiler water additives can result in the production of milk or milk product off-flavors. Manufacturers' instructions regarding recommended water level and blow-down should be consulted and rigorously followed. The blow-down of the boiler should be carefully watched so that an over- concentration of the boiler water solids and foaming is avoided. It is recommended that periodic analyses be made of condensate samples. Such samples should be taken from the line between the final steam separating equipment and the point of the introduction of steam into the milk or milk product.
PIPING ASSEMBLIES
Refer to Figures 49 and 50 for suggested piping assemblies for steam infusion or injection. Other assemblies that will assure a clean, dry saturated steam are acceptable.
Figure 49 - Culinary Steam Piping Assembly for Steam Infusion or Injection
| 1. Steam Main Device | 9. *Differential Pressure Measuring Device | | --- | --- | | 2. Stop Valve | 10. *Filtering Device | | 3. Strainer | 11. *Stainless Steel (from this point) | | 4. *Entrainment Separator | 12. *Sanitary Piping and Fittings (from this point) | | 5. *Condensate Trap | 13. *Spring-loaded Sanitary Check Valve | | 6. Pressure Gauge | 14. *Sanitary Piping To Process Equipmen | | 7. Steam Pressure Regulating (reducing) Valve | 15. *Sampling Means | | 8. Steam Throttling Valve (automatic or manual) or Orifice | |
*Required Equipment
Figure 50 - Culinary Steam Piping Assembly for Steam Infusion or Injection (Optional Configuration)
Figure 51 - Culinary Steam Piping Assembly for Airspace Heating or Defoaming
IV. THERMOMETER SPECIFICATIONS INDICATING THERMOMETERS FOR BATCH PASTEURIZERS
Type
- Mercury Actuated Direct Reading
a. Contained in a corrosion-resistant case which protects against breakage and permits easy observation of the column and scale.
b. Filling above mercury-nitrogen or other suitable gas.
c. The mercury column shall be magnified to an apparent width of not less than 1.6 millimeters (0.0625 of an inch).
- Digital Stand Alone
a. No more than 0.2°C (0.5°F) drift over three (3) months use on a batch pasteurizer compared to a certified temperature source.
b. Self-diagnostic circuitry which provides constant monitoring of all sensing, input, and conditioning circuits. The diagnostic circuitry should be capable of detecting “open” circuits, “short” circuits, poor connections, and faulty components. Upon detection of failure of any component, the device shall be blank or become unreadable.
c. The electromagnetic compatibility of this device for this use shall be documented and available to the Health Officer. The device shall be tested to determine the effects of electrostatic discharge, power fluctuation, conductive emission and susceptibility, and radiative emission and susceptibility. The device shall comply with the requirements for performance level characteristics of industrial devices.
d. The effect of exposure to specific environmental conditions shall be documented. The device shall be tested to determine the effects of low and high temperatures, thermal shock, humidity, physical shock, and salt fog.
e. Both the probe and the display case shall be constructed so that they may be sealed by the Health Officer.
f. Calibration of the device shall be protected against unauthorized changes.
g. The device shall be protected against unauthorized component or sensing element replacement. Replacement of any component or sensing element shall be regarded as a replacement of the indicating thermometer and subject to the Health Officer’s inspection and all application tests under Appendix I.
h. The sensing element shall be encased in appropriate material constructed in such a way that the final assembly meets the conditions of Item 11p 420-3-16-.10(11).
i. The device shall be tested from the sensing probe through the final output.
- Digital Combination
a. No more than 0.2°C (0.5°F) drift over three (3) months use on a batch pasteurizer compared to a certified temperature source.
b. Self-diagnostic circuitry which provides constant monitoring of all sensing, input, and conditioning circuits. The diagnostic circuitry should be capable of detecting “open” circuits, “short” circuits, poor connections, and faulty components. Upon detection of failure of any component, the temperature sensors output signal and indicating display shall go visibly out of range.
c. The electromagnetic compatibility of this device for this use shall be documented and available to the Health Officer. The device shall be tested to determine the effects of electrostatic discharge, power fluctuation, conductive emission and susceptibility, and radiative emission and susceptibility. The device shall comply with the requirements for performance level characteristics of industrial devices.
d. The effect of exposure to specific environmental conditions shall be documented. The device shall be tested to determine the effects of low and high temperatures, thermal shock, humidity, physical shock, and salt fog.
e. Both the probe and the display case shall be constructed so that they may be sealed by the Health Officer.
f. Calibration of the device shall be protected against unauthorized changes.
g. The device shall be protected against unauthorized component or sensing element replacement. Replacement of any component or sensing element shall be regarded as a replacement of the indicating thermometer and subject to the Health Officer’s inspection and all application tests under Appendix I.
h. The sensing element shall be encased in appropriate material constructed in such a way that the final assembly meets the conditions of Item 11p.
i. The device shall be tested from the sensing probe through the final output.
Scale - Shall have a span of not less than 14° (25°F), including the pasteurization temperature, ± 2.5°C (± 5°F); graduated in 0.5°C (1ºF) divisions, with not more than 9°C (16°F) per 2.54 centimeters (1 inch) of span; and protected against damage at 105°C (220°F). Provided, that on batch pasteurizers used solely for thirty (30) minute pasteurization of milk and milk products at temperatures above 71°C (160°F), indicating thermometers with 1°C (2°F) scale graduations, with not more than 6°C (28°F) per 2.54 centimeters (1 inch) of scale, may be used.
Accuracy - Within ± 0.2°C (± 0.5°F), through the specified scale span. Provided, that on batch pasteurizers used solely for thirty (30) minute pasteurization of milk and milk products at temperatures above 71°C (160°F), indicating thermometers shall be accurate to within ±.5°C (± 1°F) (refer to Appendix I, Test 1).
Submerged Stem Fitting - A pressure-tight seat against the inside wall of the holder; no threads exposed to milk or milk products; and the location of this seat to conform to the 3-A Sanitary Standard for a wall-type fitting or other equivalent sanitary fitting.
Bulb - Corning normal or equally suitable thermometric glass.
INDICATING THERMOMETERS LOCATED ON PASTEURIZATION PIPELINES
Type
- Mercury Actuated Direct Reading
a. Contained in a corrosion-resistant case which protects against breakage and permits easy observation of the column and scale.
b. Filling above mercury - nitrogen or other suitable gas.
c. The mercury column shall be magnified to an apparent width of not less than 1.6 millimeters (0.0625 of an inch).
- Digital
a. No more than 0.2°C (0.5°F) drift over three (3) months use on a HTST system compared to a certified temperature source.
b. Self-diagnostic circuitry which provides constant monitoring of all sensing, input, and conditioning circuits. The diagnostic circuitry should be capable of detecting “open” circuits, “short” circuits, poor connections and faulty components. Upon detection of failure of any component, the device shall blank or become unreadable.
c. The electromagnetic compatibility of this device for this use shall be documented and available to the Health Officer. The device shall be tested to determine the effects of electrostatic discharge, power fluctuation, conductive emission and susceptibility, and radiative emission and susceptibility. The device shall comply with the requirements for performance level characteristics of industrial devices.
d. The effect of exposure to specific environmental conditions shall be documented. The device shall be tested to determine the effects of low and high temperatures, thermal shock, humidity, physical shock, and salt fog.
e. Both the probe and the display case shall be constructed so that they may be sealed by the Health Officer.
f. Calibration of the device shall be protected against unauthorized changes.
g. The device shall be protected against unauthorized component or sensing element replacement. Replacement of any component or sensing element shall be regarded as a replacement of the indicating thermometer and subject to the Health Officer’s inspection and all applicable tests under Appendix I.
h. The sensing element shall be encased in appropriate material constructed in such a way that the final assembly meets the conditions of Item 11p.
i. The device shall be tested from the sensing probe through the final output.
Scale: Shall have a span of not less than 14°C (25°F), including the pasteurization temperature, ± 2.5°C (± 5°F); and protected against damage at 105°C (220°F), and in the case of thermometers used on HHST pasteurization systems protected against damage at 149°C (300°F). Mercury actuated thermometers shall be graduated in 0.2°C (0.5°F) divisions with not more than 4°C (8°F) per 2.54 centimeters (one [1] inch) of scale. The digital thermometer readout shall display in units no greater than of 0.05°C (0.1°F).
Accuracy: Within ± 0.2°C (± 0.5°F), throughout the specified scale span (refer to Appendix I, Test 1).
Stem Fittings: A pressure-tight seat against the inside wall of the fittings; no threads exposed to milk or milk products. The probe is to be designed so that the sensitive area is discernible from the remainder of the stem. The overall probe length to be such that the sensitive area is positioned in the milk or milk product flow path when properly installed.
Thermometric Response: When the thermometer is at room temperature and then is immersed in a well-stirred water bath 11°C (19°F) or less above the pasteurization temperature, the time required for the reading to increase from water bath temperature, minus 11°C (19°F), to water bath temperature, minus 4°C (7°F), shall not exceed four (4) seconds. The digital thermometer displays shall change at a rate that can be noted by the operator or Health Officer during the thermometric lag test (refer to Appendix I, Test 7).
Bulb: Corning normal or equally suitable thermometric glass.
AIRSPACE INDICATING THERMOMETER FOR BATCH PASTEURIZERS
Type
- Mercury Actuated Direct Reading
a. Contained in a corrosion-resistant case which protects against breakage and permits easy observation of the column and scale.
b. The bottom of the bulb chamber shall not be less than fifty-one (51) millimeters (two [2] inches) and not more than eighty-nine (89) millimeters (3.5 inches), below the underside of the cover.
c. Filling above mercury-nitrogen or other suitable gas.
d. The mercury column shall be magnified to an apparent width of not less than 1.6 millimeters (0.0625 of an inch).
- Digital Stand Alone
a. No more than 0.2°C (0.5°F) drift over three (3) months use on a batch pasteurizer compared to a certified temperature source.
b. Self-diagnostic circuitry which provides constant monitoring of all sensing, input, and conditioning circuits. The diagnostic circuitry should be capable of detecting “open” circuits, “short” circuits, poor connections, and faulty components. Upon detection of failure of any component, the device shall be blank or become unreadable.
c. The electromagnetic compatibility of this device for this use shall be documented and available to the Health Officer. The device shall be tested to determine the effects of electrostatic discharge, power fluctuation, conductive emission and susceptibility, and radiative emission and susceptibility. The device shall comply with the requirements for performance level characteristics of industrial devices.
d. The effect of exposure to specific environmental conditions shall be documented. The device shall be tested to determine the effects of low and high temperatures, thermal shock, humidity, physical shock, and salt fog.
e. Both the probe and the display case shall be constructed so that they may be sealed by the Health Officer.
f. Calibration of the device shall be protected against unauthorized changes.
g. The device shall be protected against unauthorized component or sensing element replacement. Replacement of any component or sensing element shall be regarded as a replacement of the indicating thermometer and subject to the Health Officer’s inspection and all application tests under Appendix I.
h. The sensing element shall be encased in appropriate material constructed in such a way that the final assembly meets the conditions of Item 11p Rule 420-3-16-.10(11).
i. The device shall be tested from the sensing probe through the final output.
j. The bottom of the bulb chamber is not less than fifty-one (51) millimeters (two [2] inches) and not more than eight-nine (89) millimeters [3.5 inches], below the underside of the cover.
- Digital Combination:
a. No more than 0.2°C (0.5ºF) drift over three (3) months use on a batch pasteurizer compared to a certified temperature source.
b. Self-diagnostic circuitry which provides constant monitoring of all sensing, input, and conditioning circuits. The diagnostic circuitry should be capable of detecting “open” circuits, “short” circuits, poor connections, and faulty components. Upon detection of failure of any component, the temperature sensors output signal and indicating display shall go visibly out of range.
c. The electromagnetic compatibility of this device for this use shall be documented and available to the Health Officer. The device shall be tested to determine the effects of electrostatic discharge, power fluctuation, conductive emission and susceptibility, and radiative emission and susceptibility. The device shall comply with the requirements for performance level characteristics of industrial devices.
d. The effect of exposure to specific environmental conditions shall be documented. The device shall be tested to determine the effects of low and high temperatures, thermal shock, humidity, physical shock, and salt fog.
e. Both the probe and the display case shall be constructed so that they may be sealed by the Health Officer.
f. Calibration of the device shall be protected against unauthorized changes.
g. The device shall be protected against unauthorized component or sensing element replacement. Replacement of any component or sensing element shall be regarded as a replacement of the indicating thermometer and subject to the Health Officer’s inspection and all application tests under Appendix I.
h. The sensing element shall be encased in appropriate material constructed in such a way that the final assembly meets the conditions of Item 11p.
i. The device shall be tested from the sensing probe through the final output.
j. The bottom of the bulb chamber is not less than fifty-one (51) millimeters (two [2] inches) and not more than eighty-nine (89) millimeters (3.5 inches), below the underside of the cover.
Scale - Shall have a span of not less than 14°C (25°F), including the pasteurization temperature of 66°C (150°F), ± 2.5°C (± 5°F); graduated in not more than 1°C (2°F) divisions, with not more than 9°C (16°F) per 2.54 centimeters (1 inch) of scale; and protected against damage at (105°C) 220°F.
Accuracy - Within ± 0.5°C (± 1°F), throughout the specified scale span (refer to Appendix I, Test 1).
Stem Fittings - A pressure-tight seat or other suitable sanitary fitting with no threads exposed.
TEMPERATURE-RECORDING DEVICES FOR BATCH PASTEURIZERS
- UTILIZING TEMPERATURES LESS THAN 71°C (160°F)
Case - Moisture proof under normal operating conditions in milk plants.
Chart Scale - Shall have a span of not less than 11°C (20°F), including pasteurization temperature, ± 2.5°C (± 5°F); and graduated in temperature-scale divisions of 0.5°C (1°F), spaced not less than 1.6 millimeter (0.0625 of an inch) apart between 60°C (140°F) and 69°C (155°F). Provided, that temperature-scale divisions of 0.5°C (1°F), spaced not less than 1 millimeter (0.040 of an inch) apart, are permitted when the ink line is thin enough to be easily distinguished from the printed line; graduated in time-scale divisions of not more than ten (10) minutes; and having a chord of straight-line length of not less than 6.3 millimeters (0.25 of an inch), between 63°C (145°F) and 66°C (150°F)
Temperature Accuracy - Within ± 0.5°C (± 1° F), between 60°C (140°F) and 69°C (155°F) (refer to Appendix I, Test 2).
Time Accuracy - The recorded elapsed time as indicated by the chart rotation shall not exceed the true elapsed time, as compared to an accurate watch, over a period of at least thirty (30) minutes at pasteurization temperature. Temperature-recording devices for batch pasteurizers may be equipped with spring operated or electrically operated clocks (refer to Appendix I, Test 3).
Pen-Arm Setting Device - Easily accessible and simple to adjust for mercury-actuated recording thermometer (refer to Appendix I, Test 4).
Temperature Sensing Device
-
Mercury Actuated - Bulb, tube, and spring protected against damage at a temperature of 105°C (220°F).
-
Digital
a. No more than 0.5°C (1.0°F) drift over three (3) months use on a batch pasteurizer compared to a certified temperature source.
b. Self-diagnostic circuitry which provides constant monitoring of all sensing, input and conditioning circuits. The diagnostic circuitry should be capable of detecting “open” circuits, “short” circuits, poor connections, and faulty components. Upon detection of failure of any component, the device shall be blank, become unreadable or go visibly out of range.
c. The electromagnetic compatibility of this device for this use shall be documented and available to the Health Officer. The device shall be tested to determine the effects of electrostatic discharge, power fluctuation, conductive emission and susceptibility, and radiative emission and susceptibility. The device shall comply with the requirements for performance level characteristics of industrial devices.
d. The effect of exposure to specific environmental conditions shall be documented. The device shall be tested to determine the effects of low and high temperatures, thermal shock, humidity, physical shock, and salt fog.
e. Both the probe and the display case shall be constructed so that they may be sealed by the Health Officer.
f. Calibration of the device shall be protected against unauthorized changes.
g. The device shall be protected against unauthorized component or sensing element replacement. Replacement of any component or sensing element shall be regarded as a replacement of the indicating thermometer and subject to the Health Officer’s inspection and all application tests under Appendix I.
h. The sensing element shall be encased in appropriate material constructed in such a way that the final assembly meets the conditions of Item 11p Rule 420-3-16-.10(11).
Submerged Stem Fitting - A pressure-tight seat against the inside wall of the holder; no threads exposed to milk or milk products; and the distance from the underside of the ferrule to the sensitive portion of the bulb to be not less than seventy-six (76) millimeters (three [3] inches).
Chart Speed - A circular chart shall make one (1) revolution in not more than twelve (12) hours. Two (2) charts shall be used if operations extend beyond twelve (12) hours in one (1) day. Circular charts shall be graduated for a maximum record of twelve (12) hours. Strip-charts may show a continuous recording over a twenty-four (24) hour period.
Chart Support Drive - The rotating chart support drive shall be provided with a pin to puncture the chart in a manner to prevent its fraudulent rotation.
- UTILIZING TEMPERATURES GREATER THAN 71°C (160°F)
Batch pasteurizers used solely for thirty (30) minute pasteurization of milk and milk products at temperature above 71°C (160°F) may use temperature-recording devices that comply with 1. with the following options:
Chart Scale - Graduated in temperature scale divisions of 1°C (2°F), spaced not less than 1 millimeter (.040 of an inch) apart between 65°C (150°F) and 77°C (170°F); graduated in time- scale divisions of not more than fifteen (15) minutes; and having a chord of straight-line length of not less than 6.3 millimeters (0.25 of an inch) between 71°C (160°F) and 77°C (170°F).
Temperature Accuracy - Within ± 1°C (± 2° F), between 71°C (160°F) and 77°C (170°F).
Digital Temperature Sensing Device - No more than 1°C (2°F) drift over three (3) months use on a batch pasteurizer compared to a certified temperature source.
Chart Speed - A circular chart shall make one (1) revolution in not more than twenty-four (24) hours and shall be graduated for a maximum record of twenty-four (24) hours.
RECORDER/CONTROLLERS FOR CONTINUOUS PASTEURIZERS
Case - Moisture proof under normal operating conditions in milk pasteurization plants.
Chart Scale - Shall have a span of not less than 17°C (30°F), including the temperature at which diversion is set, ± 7°C (± 12°F); graduated in temperature scale divisions of 0.5°C (1°F), spaced not less than 1.6 millimeter (0.0625 of an inch) apart at the diversion temperature, ± 0.5°C (± 1°F). Provided, that temperature-scale divisions of 0.5°C (1°F), spaced not less than 1 millimeter (0.040 of an inch) apart, are permitted when the ink line is thin enough to be easily distinguished from the printed line; graduated in time-scale divisions of not more than fifteen (15) minutes; and having an equivalent fifteen (15) minute chord or straight-line length of not less than 6.3 millimeters (0.25 of an inch) at the diversion temperature, ± 0.5°C (± 1°F).
Temperature Accuracy - Within ± 0.5°C (± 1°F), at the temperature, ± 3°C (± 5°F), at which the controller is set to divert (refer to Appendix I, Test 2).
Power Operated - All recorder/controllers for continuous pasteurization shall be electrically operated.
Pen-Arm Setting Device - Easily accessible and simple to adjust for mercury-actuated recording thermometer (refer to Appendix I, Test 4).
Pen and Chart Paper - Pen designed to give a line not over .07 millimeters (0.025 of an inch) wide and easy to maintain.
Temperature Sensing Device
-
Mercury Actuated - Bulb, tube, and spring protected against damage at a temperature of 105°C (220°F). Provided, that the recorder/controller temperature sensing devices used on HHST systems shall be protected against damage at temperatures of 149°C (300°F).
-
Digital
a. No more than 0.5°C (1.0°F) drift over three (3) months use on a HTST pasteurization system compared to a certified temperature source.
b. Self-diagnostic circuitry which provides constant monitoring of all sensing, input, and conditioning circuits. The diagnostic circuitry should be capable of detecting “open” circuits, “short” circuits, poor connections, and faulty components. Upon detection of failure of any component, the device shall be blank or become unreadable.
c. The electromagnetic compatibility of this device for this use shall be documented and available to the Health Officer. The device shall be tested to determine the effects of electrostatic discharge, power fluctuation, conductive emission and susceptibility, and radiative emission and susceptibility. The device shall comply with the requirements for performance level characteristics of industrial devices.
d. The effect of exposure to specific environmental conditions shall be documented. The device shall be tested to determine the effects of low and high temperatures, thermal shock, humidity, physical shock, and salt fog.
e. Both the probe and the display case shall be constructed so that they may be sealed by the Health Officer.
f. Calibration of the device shall be protected against unauthorized changes.
g. The device shall be protected against unauthorized component or sensing element replacement. Replacement of any component or sensing element shall be regarded as a replacement of the indicating thermometer and subject to the Health Officer’s inspection and all applicable tests under Appendix I.
h. The sensing element shall be encased in appropriate material constructed in such a way that the final assembly meets the conditions of Item 11p.
i. The device shall be tested from the sensing probe through the final output.
Stem Fitting - A pressure-tight seat against the inside wall of the pipe; no threads exposed to milk or milk products; and the distance from the underside of the ferrule to the sensitive portion of the bulb is to be not less than 76 millimeters (3 inches).
Chart Speed - A circular chart shall make one (1) revolution in not more than twelve (12) hours. Two (2) charts shall be used if operations extend beyond twelve (12) hours in one (1) day. Circular charts shall be graduated for a maximum record of twelve (12) hours. Strip-charts may show a continuous recording over a twenty-four (24) hour period.
Frequency Pen - The recorder/controller shall be provided with an additional pen-arm located on the outer edge of the chart, for recording the time at which the FDD is in the forward or diverted-flow position. The chart time line shall correspond with the reference arc and the recording pen shall rest upon the time line matching the reference arc.
Controller - Actuated by the same sensor as the recorder pen; however, the cut-in and cut-out response shall be independent of pen-arm movement.
Controller Adjustment - A mechanism for the adjustment of the response temperature. It shall be designed so that the temperature setting cannot be altered or the controller manipulated without detection.
Thermometric Response - With the recorder/controller bulb at room temperature and then immersed in sufficiently agitated water or oil bath at 4ºC (7ºF) above the cut-in point, the interval between the moment when the recording thermometer reads 7ºC (12ºF) below the cut-in temperature and the moment of power cut-in shall be not more than five (5) seconds (refer to Appendix I).
Chart Support Drive - The rotating chart support drive shall be provided with a pin to puncture the chart in a manner to prevent its fraudulent rotation.
INDICATING THERMOMETERS USED IN STORAGE TANKS
Scale Range - Shall have a span not less than 28°C (50°F) Fahrenheit, including normal storage temperatures, ± 3°C (± 5°F), with an extension of scale on either side permitted, and graduated in not more than 1°C (2°F) divisions.
Temperature Scale Division - Spaced not less than 1.6 millimeters (0.0625 of an inch) apart between 2°C (35°F) and 13°C (55°F).
Accuracy - Within ± 1°C (± 2°F) throughout the specified scale range.
Stem Fitting - A pressure-tight seat or other suitable sanitary fittings with no threads exposed.
TEMPERATURE-RECORDING DEVICES USED IN STORAGE TANKS
Case - Moisture proof under operating conditions in milk plants.
Chart Scale - Shall have a scale span of not less than 28°C (50°F) including normal storage temperature, ± 3°C (± 5°F), graduated in not more than 1°C (2°F) divisions. Lines spaced not less than 1 millimeter (0.040 of an inch) apart are permitted when the ink line is thin enough to be easily distinguished from the printed line. They shall be graduated in time scale divisions of not more than one (1) hour, having a chord of straight-line length of not less than 3.2 millimeters (0.125 of an inch) at 5°C (41°F). These charts shall be capable of recording temperatures up to 83°C (180°F). Span specifications do not apply to extensions beyond 38°C (100°F).
Temperature Accuracy - Within ± 1°C (± 2°F), between the specified range limits.
Pen-Arm Setting Device - Easily accessible and simple to adjust.
Pen and Chart Paper - Designed to make a line not over .635 millimeters (0.025 of an inch) wide when in proper adjustment and easy to maintain.
Temperature Sensor - Protected against damage at 100°C (212°F).
Stem Fittings - A pressure-tight seat or other suitable sanitary fitting with no threads exposed.
Chart Speed - The circular chart shall make one (1) revolution in not more than seven (7) days and shall be graduated for a maximum record of seven (7) days. Strip chart shall move not less than 2.54 centimeters (1 inch) per hour and may be used continuously for one (1) calendar month.
TEMPERATURE-RECORDING DEVICES ON MECHANICAL CLEANING SYSTEMS
Location - Temperature sensor is in the return solution line downstream from the process.
Case - Moisture proof under operation conditions.
Chart Scale - Shall have a range from 16°C (60°F) to 83°C (180°F), with extensions of scale on either side permissible and graduated in time-scale divisions of not more than fifteen (15) minutes. The chart is to be graduated in temperature divisions of not more than 1°C (2°F), spaced not less than 1.6 millimeters (0.0625 of an inch) apart, above 44°C (110°F). Provided, that temperature-scale divisions of 1°C (2°F), spaced not less than 1 millimeter (0.040 of an inch) apart, are permitted when the ink line is thin enough to be easily distinguished from the printed line.
Temperature Accuracy - Within ± 1°C (± 2°F), above 44°C (110°F).
Pen-Arm Setting Device - Easily accessible and simple to adjust.
Pen and Chart Paper - Designed to make a line not over .635 millimeters (0.025 of an inch) wide and easy to maintain.
Temperature Sensor - Protected against damage at 100°C (212°F).
Stem Fitting - A pressure-tight seat against the inside wall of the pipe with no threads exposed to solution.
Chart Speed - Circular charts shall make one (1) revolution in not more than twenty-four (24) hours. Strip charts shall not move less than 25 millimeters (1 inch) per hour. More than one (1) record of the cleaning operation shall not overlap on the same section of the chart for either circular or strip-type charts.
INDICATING THERMOMETERS USED IN REFRIGERATED ROOMS WHERE MILK AND MILK PRODUCTS ARE STORED SHALL MEET THE FOLLOWING SPECIFICATIONS:
Scale Range - Shall have a span not less than 28°C (50°F), including normal storage temperatures, ± 3°C (± 5°F), with extensions of scale on either side permitted if graduated in not more than 1°C (2°F) divisions.
Temperature Scale Divisions - Spaced not less than 1.6 millimeters (0.0625 of an inch) apart between 0°C (32°F) and 13°C (55°F).
Accuracy - Within ± 1°C (± 2°F), throughout the specified scale ranges.
SPECIFICATIONS FOR RECORDING pH METER FOR USE ON AUTOMATED CIP CLEANING SYSTEMS FOR EVAPORATORS
Location - pH sensor shall be located in the return line downstream from processing equipment and all lines included in the CIP cleaning circuit.
Case: Moisture proof under operating conditions.
Chart Scale - It shall have a range of pH value from two (2) to twelve (12), with extensions of scale on either side permissible, and graduated in time scale divisions of not more than fifteen (15) minutes. The chart is to be graduated in pH divisions of not more than 0.5 pH values and spaced not less than 1.6mm (0.0625 of an inch) apart.
pH Accuracy - Within 0.5, plus or minus pH values.
Pen-Arm Setting Device - Easily accessible; simple to adjust.
Pen and Chart Paper - Designed to mark a line not over 0.635mm (0.025 of an inch) wide; easy to maintain.
pH Sensor - Protected against damage at 83°C (180°F).
Chart Speed - Circular charts shall make one (1) revolution in not more than twenty-four (24) hours. Strip charts shall not move slower than 25mm (1 inch) per hour. More than one (1) record of the cleaning operation shall not overlap on the same section of the chart for either circular or strip-type charts.
V. CRITERIA FOR THE EVALUATION OF ELECTRONIC DATA COLLECTION, STORAGE, AND REPORTING
BACKGROUND
Electronically collecting data storing data and reporting information with computers can be a beneficial replacement for circular chart recorders and/or hand-written records. This method of presenting Grade “A” PMO required information should essentially replace and duplicate the purpose and functionality of their manual or chart recorder counterparts. These would include CIP records, pasteurization records, raw and heat-treated product storage tank's temperature and cleaning requirements, and temperature monitors for membrane filtration. This criteria for the evaluation addresses the difference between manual records or chart recorders and electronic or computer record keeping. These differences are identified in the criteria below that address the verification of system reliability, security and dependability, and what information is available and accurate for assuring public health safety and inspection.
Following are some of the differences between manual records and chart recorders as compared to electronically collecting data, storing data, and reporting information using computers:
-
Manual Records and Chart Recorders are Visual in Nature - Milk plant employees and regulatory personnel can see and physically hold the records and place them in files for safe keeping. Whereas computerized data collection systems are not so, they need to have methods in place to assure that the information is reliably placed and safe.
-
Manual Records and Chart Recorders are Physical in Nature - Milk plant employees and regulatory personnel can physically record on and actually sign the records and; therefore, become responsible for the required public health activity. Also, the quality assurance manager is typically responsible for the integrity of the stored records. Whereas, computerized data collection and reporting systems need to collect the identity of the person performing the function and they also need to have someone at each milk plant responsible for the integrity of the stored records.
-
Manual Records and Chart Recorders are Typically Hard Wired Directly to Dedicated Instrumentation - Very little complexity exists between the sensor, such as a temperature or flow sensor, and the final recording device. This allows routine maintenance and compliance monitoring and inspection of manual records and chart recorders to be relatively simple. Whereas the computerized data collection, storage, and reporting systems need to have documented procedures in place to assure that system changes, upgrades, and normal operating procedures do not compromise the integrity of the public health safety information and reports.
CRITERIA - The following criteria are to be used for the evaluation of electronic collection, storage, and recording or reporting of any information required within Items 12p and 16p(D), Rules 420-3-16-.10(12) and 420-3-16-.10(21).
Note: These criteria do not address computer instrumentation or the electronic control of pasteurization for public health safety.
All computer-generated records and reports shall contain the information required in these rules that is applicable. The computerized data collection, storage, and reporting system shall have an assigned and identified representative from the milk plant that is responsible for the system. This person’s name shall be available to the Health Officer and the FDA.
-
Any computer required in the making of a public health safety report, including data collection computers, data storage computers, or report servers shall be powered with an Uninterruptible Power Supply (UPS) capable of maintaining power to the computerized data collection, storage, and reporting system for twenty (20) minutes.
-
A written user's guide of the computerized data collection, storage and reporting system shall be provided and will explain the system’s architecture, the software used, and the sensors or instruments monitored. This overview may be presented in text or in a graphical representation. A copy of this overview shall be maintained at the discretion of the Health Officer. This document shall bear the name of the identified representative from the milk plant assigned to administrate this procedure and be available for review at the milk plant by the Health Officer and the FDA. This documentation shall explain:
a. System’s architecture, the software used, and the sensors or instruments monitored.
b. Reporting interface of the computerized data collection, storage, and reporting system.
c. Backup procedure for ensuring the safe storage of the public health safety data of all reports.
d. Procedure for any changes or maintenance to the instrumentation, sensors, hardware, or computers. This procedure will explain how the plant will ensure that when a physical change occurs, the information affected has been checked for accuracy.
e. Listing and explanation of the reports available on the system, instructions on how to access the reports, and examples of each report with a description of their content.
-
A written record shall be maintained by the milk plant identifying any changes or updates to the computerized data collection, storage and reporting system, software, drivers, networking, or servers in order to assure the collection, storage, or reporting of any data needed for compliance has not been compromised. This document shall bear the name of the representative from the milk plant assigned to administer this procedure and be available for review at the milk plant by the Health Officer and the FDA.
-
In the case of CIP and raw and heat-treated storage tank records, data shall be stored at a rate to provide a reasonable account of the process being recorded. This shall never exceed a maximum of fifteen (15) minutes between data records. The data for the reporting system shall be backed up at least once every twenty-four (24) hours. Alternatively, the final reports may be stored and backed up at least once every twenty-four (24) hours.
-
In the case of pasteurization records, data shall be stored no less than every five (5) seconds for each required variable. Any event required to be recorded in manual reporting, such as a divert condition, shall be recorded no matter how short the duration. Provisions shall be made to allow operators to report additional events electronically, such as a record of unusual occurrences. The data for the reporting system shall be backed up at least once every twenty-four (24) hours. Alternatively, the final reports may be stored and backed up at least once every twenty-four (24) hours.
-
Upon the initial installation, computer generated reports shall be verified visually for accuracy for seven (7) consecutive days and be found to be accurate and error free in actual service in the milk plant where installed. These seven (7) days of reports shall be printed out and shall bear the signature of both the vendor of the system and the identified representative from the milk plant, or they shall be accompanied by a cover letter signed by the vendor and the identified representative from the milk plant. If the milk plant develops the computerized data collection, storage, and reporting system, the programmer and the identified representative from the milk plant shall be two (2) different individuals. This seven (7) day report verification period shall only be required at initial installation and one (1) time only whenever a chart recorder and/or hand-written record is being replaced by electronic data collection, storage, and reporting. These seven (7) days of reports shall be kept on file at the milk plant and a copy shall be provided to the Health Officer when requested.
-
Whenever changes, updates, or observed anomalies that affect the reliability or accuracy of the reporting system occur following the initial installation of the system, these changes, updates, or observed anomalies shall be evaluated and investigated and if corrections are warranted shall be addressed. The records of each evaluation and corrections made shall bear the signature of the vendor or the identified representative from the milk plant. The records shall be maintained and be available for the Health Officer when requested.
-
The electronic computerized data collection, storage, and reporting system shall provide for any signatures or initials required by these rules. Acceptable operator signatures or initials captured electronically may be any combination of alpha and/or numeric characters that identify the individual performing the test or operation. Input of this signature or initials may be done by any means, including but not limited to, a biometric reader, a card or radio frequency device, or by simple direct entry that provides a unique identifier directly associated with a specific person. Input of this signature or initials shall occur each time it is required by these rules. Except, that in the case of pasteurization records, the operator’s signature or initials shall occur whenever an operator changes and at a minimum frequency of once every twenty-four (24) hours.
-
The data supporting electronic reports shall be stored in a database or data archival system in a Write Once, Read Many (WORM).
-
The system shall provide an anomalies report indicating any system or communication failure that could have affected the validity of the required reports. This anomalies report shall be automatically attached to any report that may have been affected by the system anomaly. A separate error log or system log shall not suffice for meeting this requirement, since any anomaly requires an evaluation and investigation to correlate the anomaly.
Note: While electronic and computerized systems can furnish a wide range of process validation and anomaly reporting, these criteria only require appended reporting of data loss that affects the reports that are required to comply with this Appendix and Items 12p and 16p(D) or other required reporting contained in Rules 420-3-16-.10(12) and 420-3-16-.10(21).
-
When a report is viewed on a computer screen, this format is exempt from the graduated temperature divisions, temperature-scale divisions, and line spacing requirements of this appendix.
-
Printed reports shall present data in a form that is compatible with the applicable requirements of these rules.
VI. CRITERIA FOR THE EVALUATION OF COMPUTERIZED SYSTEMS FOR GRADE "A" PUBLIC HEALTH CONTROLS
BACKGROUND
Computer systems are commonly used to manage the functions of public health control devices (valves, pumps, etc.) that operate milk pasteurization systems. These computer systems may be programmed for monitoring and controlling the instrumentation of HTST and HHST pasteurizers. They may also control the operational state of devices such as the FDDs, booster pumps, etc. While this technology can furnish numerous advantages throughout the manufacturing process, the public health computer system should essentially just replace its hard-wired counterpart. These computer systems are evaluated similar to hard-wired systems and all of the required public health controls shall meet the established criteria. Computers are different from hard-wired controls in three (3) major categories. To provide adequate public health protection, the design of computerized public health controls shall address these three (3) major differences.
First, unlike conventional hard-wired systems which provide full-time monitoring of the public health controls, the computer performs its tasks sequentially, and the computer may be in real time contact with the FDD for only one (1) millisecond. During the next one hundred (100) milliseconds, or however long it takes the computer to cycle one (1) time through its tasks, the FDD remains in forward-flow, independent of temperature in the holding tube. Normally, this is not a problem because most computers can cycle through one hundred (100) steps in their program, many times during one (1) second. The problem occurs when the public health computer is directed away from its tasks by another computer; or the computer program is changed; or a seldom used JUMP, BRANCH, or GOTO Instruction diverts the public health computer away from its tasks.
Second, in a computerized system, the control logic is easily changed because the computer program is easily changed. A few keystrokes at the keyboard will completely change the control logic of the computer program. Sealing the access to the public health computer's programming function can solve the problem addressed above. A procedure is needed to ensure that the public health computer has the correct program when the Health Officer reseals the public health computer.
Finally, for public health controls, the public health computer program shall and can be made error-free since the programs required for public health control are relatively brief. This is accomplished by attempting to keep the public health computer program simple and of limited control scope.
GLOSSARY
Address - A numerical label on each memory location of the computer. The computer uses this address when communicating with the input or output.
Computer - A very large number of on-off switches arranged in a manner to sequentially perform logical and numerical functions.
Default Mode - The pre-described position of some memory locations during start-up and standby operations of the computer.
EAPROM - An Electrically Alterable, Programmable, Read-Only Memory. Individual memory locations may be altered without erasing the remaining memory.
EEPROM - An Electrically Erasable Programmable, Read-Only Memory. The entire memory is erased with one (1) electrical signal.
EPROM - An Erasable, Programmable, Read-Only Memory. The entire memory is erased by exposure to ultra-violet light.
Fail-Safe - Design considerations that cause the instrument or system to move to the safe position upon failure of electricity, air, or other support systems.
Field Alterable - A device having a specific design or function that is readily changed by the user and/or the maintenance personnel.
FDD - The common acronym used for flow-diversion valves or devices on pasteurization systems.
Force Off - A programmable computer instruction that places any input or output in the "off" state, independently of any other program instructions.
Force On - A programmable computer instruction that places any input or output in the "on" state, independently of any other program instructions.
Human Machine Interface - Often referred to as operator interface, this computer station allows personnel monitoring and control of the computer system normally by use of a touch screen or keyboard.
Input - Electrical signals applied to the computer and used by the computer to make logical decisions on whether or not to activate one or more outputs. Input consists of data from temperature and pressure instruments, liquid level controls, PDDs, and operator-controlled panel switches.
Input/Output Terminals - The input/output terminals are the electrical panels that provide for connection of all the inputs and outputs to the computer. The input/output address labels are found on this panel. Indicator lights showing the status, “on” or “off,” of all inputs and outputs may be available on this panel. This terminal is typically located on the computer and is commonly known as a “bus.”
Ladder Logic Diagram - A programming language typically used for industrial computers commonly used and applied to milk pasteurization systems.
Last State Switch - A manually operated switch or software setting that instructs the computer to place all outputs in the "on,” "off,” or "last state" condition during a start-up. The "last state" position instructs the computer to place the outputs in whatever state, on or off, occurred during the last loss of power.
Operator Override Switch - A manually operated switch that permits the operator to place any input or output in the “on” or “off” position, independently of any program instructions.
Output - Electrical signals from the computer that turn on or off valves, motors, lights, horns, and other devices being controlled by the computer. Outputs may also consist of messages and data to the operator.
Position Detecting Device (PDD) - Mechanical limit switches (micro-switches) or electronic proximity switches capable of providing an electrical signal.
Programmable Logic Controller (PLC) - Also known as PLCs, this is a computer commonly used to control industrial machines, instruments, and processes.
RAM - Random Access Memory is memory used by the computer to run programs; store data; read input and control outputs. The computer may either read data from the memory or write data into the memory.
ROM - Read-Only Memory is memory used by the computer to run its own internal unchangeable programs. The computer may only read from the memory. It cannot write into the memory or alter the memory in any way.
RTD - Resistance Temperature Detector
Standby Status - The computer is turned on, running, and waiting for instructions to start processing input data. A manually operated switch usually accomplishes this instruction.
Status Printing - Some computers are programmed to interrupt printing of the chart record and print the status of key set points and conditions such as: cold milk temperature, holding tube temperature, diversion temperature setting, and chart speed.
WORM - Write Once, Read Many is a data storage technology that allows information to be written to a device a single time and prevents the device from erasing the data.
CRITERIA
The following listed criteria shall be complied with for all computers when applied to HTST and HHST pasteurization systems used for Grade “A” milk and/or milk products. In addition, all systems shall conform to all other existing requirements of these rules.
-
A computer or a PLC used for the public health control of a pasteurizer shall be dedicated only to the public health control of that individual pasteurizer. The public health computer shall have no other assignments involving the routine operation of the milk plant. Computer functions peripheral to the public health controls, such as CIP valve cycling, may be acceptable; provided, it does not compromise the public health functionality of the public health computer or pasteurization system and all rule requirements and safeguards are not compromised.
-
The public health computer and its outputs shall not be under the command or control of any other computer system or Human Machine Interface. It shall not have an address that is addressable by any other computer system. A host computer cannot override its commands or place it on standby status. All addresses of the public health computer shall be ready to process data at any time.
-
A separate public health computer shall be used on each HTST and HHST pasteurization system. Only the public health computer may provide control over the public health devices and functions of the HTST and HHST pasteurization system. Any other computer or Human Machine Interface may request a function of a device (valve, pump, etc.) within the HTST or HHST pasteurization system through a hard-wired input; however, this request would be granted or denied by the logic in the public health computer depending on the current status of the computer program and public health rule requirements.
-
The status of the inputs and outputs of the public health computer may be provided as inputs only to other computer systems and all public health outputs or devices shall be controlled by direct hard-wiring from the output terminal bus of the computer to the device. This includes solenoids, motor speed controls, such as frequency drives, and motors located within the HTST or HHST pasteurization system. The wiring connections shall be provided with isolation protection such as relays, diodes, or optical-coupling devices to prevent the public health outputs from being driven by the other computer system. Digital outputs from another computer may be connected to an input of the public health computer in order to request the operation of a device controlled by the public health computer. This section shall not be interpreted to prohibit control of the motor speed controls, such as frequency drives, by non-public health computer systems provided that the regulatory limits cannot be altered or disabled.
-
Upon loss of power to the public health computer all public health controls shall assume the fail-safe position. Most computers can be placed in standby status by either a program instruction or manual switches. When the public health computer is in standby status, all public health controls shall assume the fail-safe position. Some computers have internal diagnostic checks that are performed automatically during start-up. During this time, the public health computer places all outputs in default mode. In this default mode, all public health controls shall be in the fail-safe position. The status of outputs or inputs of the public health computer may provide status to another computer for informational purposes. This shall only be accomplished through a hard-wired output (separate from any control output) from the public health computer to an input on another computer system. No other communication from the public health computer is allowed.
-
Some computers and/or PLCs have Input/Output terminals (buses) with "last state switches" that permit the designer to decide what state the output bus will take on power-up, after a shutdown, or loss of power. The choices are “on,” “off,” or "last state" occurring when the computer lost power. These "last state switches" shall be placed in the “fail-safe” or “off” position. Upon loss of power to the computer, all public health controls shall assume the fail safe position. Most computers can be placed in standby status by either a program instruction or manual switches. The public health computer shall have its manual switch in the position that maintains all outputs in the “off” state during any operations except normal program execution.
-
A computer performs its tasks sequentially, and for most of real time the computer outputs are locked in the “ON” or “OFF” position, while waiting for the computer to come back through the cycle. Consequently, the public health computer program shall be written so that it monitors all inputs and updates all outputs on a precise schedule, at least once every second. Most computers will be capable of performing this function many times in one (1) second. Program instructions may not exist within the public health computer program that are capable of altering the scan order of the logic, or distract focus from this order. These would include “JUMP” or “GOTO” type instructions.
-
The computer program used to control the required public health functions of HTST or HHST pasteurizers shall be stored in some form of ROM and be available when the public health computer is turned on. The use of tapes or disks are not acceptable.
-
The public health computer program access shall be sealed. Any telephone modem accesses shall also be sealed. If the Input/Output terminals contain "last state switches,” the Input/Output terminals shall be sealed. The vendor shall supply the Health Officer with test procedures and instructions to verify that the program currently in use by the public health computer is the correct program. Typically this is made available by providing a copy of the program that controls the public health computer of the HTST or HHST pasteurizer. The Health Officer shall use this test procedure to confirm that the correct program is in use during a start-up, normal operation, and whenever the seal is broken. Challenging the system during normal operation could involve challenging the inter-wiring requirements through the CIP computer. One (1) method could include attempting access to the booster pump through the CIP computer. With the FDD mode selector in “PROCESS” or “PRODUCT” position, attempt to access the booster pump using the CIP computer. Public health controls in pasteurizers that may be compromised by such a challenge, shall be altered or re-programmed so this compromise is prevented and the access to this computer program shall be sealed by the Health Officer. Similar challenges may be performed on other required public health functions that are computer controlled.
-
If the public health computer contains FORCE-ON, FORCE-OFF functions, the public health computer shall provide indicator lights showing the status of the FORCE-ON, FORCE-OFF function. The vendor’s instructions shall remind the Health Officer that all FORCE-ON, FORCE-OFF functions shall be cleared before the public health computer is sealed by the Health Officer.
-
The Input/Output terminals of the public health computer shall contain no operator override switches that are accessible without compromising a regulatory seal.
-
Computerized systems that provide for printing the pasteurizer recording chart by the public health computer shall ensure that the required calibration is maintained. During chart printing, the public health computer shall not be diverted from its tasks for more than one (1) second. Upon returning to public health control tasks, the public health computer shall complete at least one (1) full cycle of its public health tasks before returning to chart printing.
-
When printing a chart, some systems may provide status reports on the chart paper of selected Input/Output conditions. This is usually done by interrupting the printing of the chart and printing the Input/Output conditions. Such interruptions for status printing are permitted only when a continuous record is recorded on the chart. When an interruption is initiated the time of the start of the interruption shall be printed on the chart, at the beginning of the interruption, and at the end of the interruption. The time interval during which the public health computer is diverted from its public health tasks for status printing shall not exceed one (1) second. Upon returning to public health tasks, the public health computer shall complete at least one (1) full cycle of its public health tasks before returning to status printing.
-
When the public health computer prints the holding tube temperature trace at specific intervals rather than a continuously changing line, temperature readings shall be printed not less than once every five (5) seconds. In addition, during the recorder/controller thermometric response test, the temperature shall be printed or indicated at a time rate sufficient to allow the Health Officer to measure the 7°C (12°F) rise in temperature as described in Test 8. Recorder/Controller-Thermometric Response of these rules.
-
When the public health computer prints the event pen position, the position of the FDD, either forward or divert at specific intervals, rather than continuously, all changes of position shall be recognized by the public health computer and printed on the chart. In addition, the event pen position and temperature in the holding tube shall be printed on the chart in a manner that the temperature in the holding tube can be determined at the moment of a change in position of the FDD.
-
The vendor shall provide a built-in program for test procedures or a protocol shall be provided so that all applicable public health tests, contained within Appendix I, can be performed by the Health Officer for each instrument, i.e.:
a. Recording Thermometers: Temperature accuracy; time accuracy; check against indicating thermometer and thermometric response.
b. FDD - Valve seat leakage; operation of valve stem(s); device assembly; manual diversion; response time and time delay intervals if used.
c. Booster Pumps - Proper wiring and proper pressure control settings.
d. Flow-Promoting Devices Capable of Generating Flow Through the Holding Tube - Are installed with proper wiring interlocks.
- Computers require high quality, clean, well-regulated power supplies to operate reliably and safely. Spurious voltage spikes can cause unwanted changes in public health computer RAM. To assure the public health computer will execute its functions error free the following items parameters shall be considered:
a. A “clean” power source that is relatively free of spikes, interference, and other irregularities shall be supplied to the public health computer.
b. The correct program should be confirmed at the time of sealing (refer to the criteria cited within #9 of this section).
c. The output bus “last state” switch should be in the “off” or “fail-safe” position which shall stop all functions of the HTST or HHST pasteurizer in case of a spurious program error.
d. All public health computer outputs shall not have any operator override switches and shall be wired in a manner that only allows the public health PLC complete control.
It is necessary that the installer or designer for the public health PLC ensure that the proper program is in the public health computer memory before the Health Officer seals the computer. It is also necessary that any program changes be written to the public health computer’s back-up chip if one exists.
- Computer programs used for public health controls on pasteurizers shall conform to the attached logic diagrams. Minor modifications to these diagrams are permissible to accommodate or delete items that are unique to a specific HTST or HHST pasteurization system. For example on meter based timing systems when the FDD selector switch is placed in the CIP position:
a. A minimum ten (10) minute time delay is required for the FDD to remain in diverted flow.
b. During this time delay the booster pump shall shut down and remain off for ten (10) minutes and then the Programmed CIP Operation is allowed to fully perform all the cleaning functions for the HTST or HHST pasteurization system, including allowing the timing pump, the separator, and the booster/stuffer pump to run during cleaning operations and the FDD to pulse or cycle.
-
The ladder logic diagrams for the FDD and the booster pump show a programmed CIP cleaning cycle operation as part of the computerized system. Some milk plant operators may wish to use another computer for CIP cleaning operations so that milk plant personnel may change CIP cleaning programs. When using this method, the connections between the FDD, booster pump, and milk plant computer shall be provided with solenoid relays or similar devices for the FDD and booster pump outputs. This prevents them from being operated by the milk plant computer except when the mode switch of the FDD is in the "CIP" position and all applicable requirements have been satisfied.
-
The vendor shall provide to the Health Officer a protocol and documentation as follows:
a. Wiring diagrams of those controllers, instruments, and devices pertaining to the public health computer.
b. The computer ladder logic printout and/or storage device (programmed ROM chip, etc.) identical to the public health computer that controls the pasteurizer. This is usually in the form of ladder line logic for each component of the pasteurization system(s) and may include programming for CIP and other functions.
c. A user manual including testing procedures and instructions as required in Criteria #9 of this section.
COMPUTERIZED SYSTEMS LOGIC DIAGRAMS
LEGEND
t=Time T=Temperature PDD=Position Detecting Device FDD= Flow-Diversion Device LOSA = Loss of Signal/Low Flow Alarm HFA=High Flow Alarm STLR=Safety Thermal Limit Recorder/Controller
VII. CRITERIA FOR STEAM-BLOCK TYPE FDD SYSTEMS
-
Steam-Block Type FDD Systems shall have two (2) steam-block zones between the pasteurizer and the surge tank(s)/filler(s). There shall be a continuous visible bleed of steam or condensate to the drain from each steam-block zone.
-
The steam-block zones shall be temperature monitored and shall alarm when temperature falls below 121°C (250°F).
-
The Primary Divert Valve and other critical valves shall be position detectable and fail-safe and be alarmed to provide protection when needed.
Note: For the detection of the FDD and valve seat positions (refer to Appendix H, and I, Position Detection Devices).
-
The Steam-Block Type FDD System shall not move to the forward-flow position until all conditions required of the HHST pasteurizing system are met and shall divert under the same conditions as a standard FDD.
-
When the Steam-Block Type FDD System is in a divert condition, a loss of temperature alarm in a steam-block zone shall cause a full port opening to drain in that steam-block zone.
-
Should both steam-block zones fail when the Steam-Block Type FDD is in diverted flow, the resulting compromised milk or milk product shall not be distributed for sale.
-
Computer controls shall meet the requirements of this appendix.
STEAM-BLOCK STYLE FDD SYSTEM – FUNCTIONAL DIAGRAM
VIII. MILK AND MILK PRODUCTS HACCP CCP MODELS FOR PASTEURIZATION EQUIPMENT
Milk plants regulated under the NCIMS voluntary HACCP Program shall manage pasteurization under the HACCP Plan as a CCP. Following are examples of acceptable models (HACCP Plan Summary Tables) that may be used. Other HACCP Plan Summary Tables that appropriately manage pasteurization as a CCP may also be used.
MILK AND MILK PRODUCT CONTINUOUS-FLOW (HTST AND HHST) PASTEURIZATION -- CCP MODEL HACCP PLAN SUMMARY (refer to the example on H-69).
The essential elements of HTST and HHST pasteurization are:
-
Time.
-
Temperature.
-
Pressure.
Each of these elements shall be addressed under the HACCP Plan.
-
In continuous-flow pasteurizers with sealed timing pumps, the minimum holding time at pasteurization temperature shall be addressed in the HACCP Plan as a CCP verification. Continuous-flow pasteurizers with magnetic flow meter based timing systems timed at minimum pasteurization temperature and shall be addressed as a Critical Limit (CL).
-
Temperature shall always be addressed in the HACCP Plan as a CL.
-
Pressures in the regenerator of continuous-flow pasteurizers, and in the case of HHST pasteurizers as required in the holding tubes, across steam injectors, and within infusion chambers shall be addressed in the HACCP Plan and managed as CCP verification(s).
MILK AND MILK PRODUCT VAT (BATCH) PASTEURIZATION---CCP MODEL HACCP PLAN SUMMARY (refer to the example on page H-70).
The essential elements of vat (batch) pasteurization are:
-
Time.
-
Temperature.
Both of these elements shall be addressed under the HACCP Plan as a CL.
- A properly operating HTST or HHST pasteurization system shall divert raw product to the constant-level tank when predetermined set points are not met. **Every particle of milk or milk product is heated, in a properly designed, calibrated and operated pasteurizer, to one of the temperature and time combinations specified in the current Grade "A" PMO. *** Pressures in the regenerator of coG. M. Gallaspy, Jr.ntinuous-flow pasteurizers, and in the case of HHST pasteurizers as required in the holding tubes, across steam injectors, and within infusion chambers shall be addressed in the HACCP Plan and managed as CCP verification(s). Product Description: __________________________ Signature:____________________ Intended Use and Consumer: _____________________ Date:_________________________ Method of Storage and Distribution: ________________________________
*Every particle of milk or milk product is heated, in a properly designed, calibrated and operated pasteurizer, to one of the temperature and time combinations specified in the current Grade "A" PMO. Product Description: ____________________________ Intended Use and Consumer: ___________________ Signature: ____________________________ Method of Storage and Distribution: _________________________ Date:___________________
IX. ACCEPTED PROCESS FOR THE CREATION OF PASTEURIZED EQUIVALENT WATER
UV LIGHT DISINFECTION OF WATER BACKGROUND
UV light between 2000-4000 Angstrom (200-400 nanometers) is well known for inactivating pathogenic microorganisms in water via several mechanisms, including the formation of deoxyribonucleic acid (DNA) bonds (dimers) that inhibit reproduction and infectivity. Different microbes have different responses to specific wavelengths which also can account for differences in overall dose requirements. Some microbes can use their own enzymes and mechanisms, or take advantage of host cell enzymes to repair the damaged DNA, requiring higher doses of UV to cause irrevocable damage and effective pasteurization-level disinfection.
Three (3) critical factors determine a UV unit’s ability to reliably achieve the necessary dose at any point in time: The tranmissivity of the water to UV light, the performance of the lamps, and the hydraulics and rate of the flow in the disinfection chamber. Color, turbidity, particles, and organic impurities can interfere with the transmission of UV energy and lower the disinfection efficiency below levels required to ensure destruction of pathogenic organisms. Similarly, lamps can age unevenly and water can foul the protective sleeves and prevent light from reaching some pathogens. Hydraulic patterns or flow that is too high or too low can cause uneven distribution of the dose and leave some areas without adequate disinfection.
Other important factors include the geometric configuration of the reactor, the power, wavelength, and physical arrangement of the UV lamps, and the UV path length. Longer path lengths provide more opportunities for UV photon-microbe interaction and inactivation.
UV lamps treat water instantaneously while it is flowing through the disinfection chamber but do not provide residual bactericidal action. Using UV light for pasteurized equivalent water is not a substitute for appropriate maintenance, periodic flushing, and sanitizing of the water distribution system inside the plant.
CRITERIA
The following is a list of criteria that is required to accept water treated with UV light to be considered equivalent to pasteurized water:
- UV light shall be applied so that the entire volume of water receives at least the following dose when used as pasteurized water.
a. Low pressure UV at 2,537 Angstrom (254 nanometers) at 186,000 microwatt-seconds per square centimeter or a 4-log adenovirus equivalent.
b. Medium pressure UV at 120,000 microwatt-seconds per square centimeter or a 4-log adenovirus equivalent.
-
A flow or time delay mechanism shall be provided so that all water moving past the flow stop or divert valve receives the minimum dose required above.
-
The unit shall be designed to permit the frequent cleaning of the system without disassembly of the unit and shall be cleaned often enough to ensure that the system will provide the required dose at all times.
-
An automatic flow control valve accurate within the expected pressure range shall be installed to restrict flow to the maximum design flow of the treatment unit so that all particles receive the minimum dose listed above.
-
An accurately calibrated UV intensity sensor properly filtered to restrict its sensitivity to the 2,500-2,800 Angstrom (250-280 nanometers) germicidal spectrum shall measure the UV energy from the lamps.
-
There shall be one (1) sensor for each UV lamp.
-
The light shall adjust based on water quality measured with a real time UVT analyzer to assure that the dose is always calculated accurately and provided reliably.
-
A flow diversion valve or automatic shut-off valve shall be installed which shall permit flow into the pasteurized product lines only when at least the required UV dosage is applied. When power is not being supplied to the unit, the valve should be in a closed (fail-safe) position which prevents the flow of water into the pasteurized product lines.
-
The materials of construction shall not impart toxic materials into the water either as a result of the presence of toxic constituents in materials of construction or as a result of physical or chemical changes resulting from exposure to UV energy.
-
The unit shall record the operating parameters (flow, UVT, and dose) on a real time basis. These records shall be accessible to the Health Officer for inspection. Electronically generated records, if used, shall meet the criteria specified in Appendix H and V.
History
- Author: G. M. Gallaspy, Jr.
- Authority: Code of Ala. 1975, §22-2-2 and §22-20-7.
- Repealed and New Rule: Filed October 18, 2018; effective December 2, 2018.
Ala. Admin. Code r. 420-3-16-AI Appendix I - Pasteurization Equipment and Controls - Tests
I. TESTING APPARATUS SPECIFICATIONS TEST THERMOMETER
Type:
- Mercury or Non-toxic Liquid-in-Glass-Actuated: Readily cleanable; plain front; enameled back; length at least 30.5 centimeters (12 inches); immersion point to be etched on stem and mercury or non-toxic liquid to stand in contraction chamber at 0°C (32°F). Non-toxic liquid-in-glass-actuated thermometers shall have accuracy and reliability equivalent to mercury thermometers.
Scale Range: At least 7°C (12°F) below and 7°C (12°F) above the pasteurization temperature at which the operating thermometer is used, with extensions of the scale on either side permitted and protected against damage at 149°C (300°F).
Temperature Represented by Smallest Scale Division: 0.1°C (0.2°F).
Number of Degrees per 25 Millimeters (1 inch) of Scale: Not more than 4°C or not more than 6°F.
Accuracy: Within ± 0.1°C (± 0.2°F), throughout specified scale range. The accuracy shall be checked against a thermometer which has been tested by or is traceable to NIST.
Bulb: Corning normal or equally suitable thermometric glass.
Case: Suitable to provide protection during transit and periods when not in use.
- Digital Test Thermometer: Hand-held; high accuracy digital thermometer; and battery or AC line powered. Calibration is protected from unauthorized changes.
Range: -18°C to 149°C (0ºF to 300°F); temperature represented by smallest scale division, 0.01°C or ºF and digital display.
Accuracy: System accuracy of: ± 0.056°C (± 0.100°F); Probe accuracy of: ± 0.05°C (± 0.09°F); repeatability of ± 0.005°C (± 0.009°F); three (3) month stability: ± 0.025°C (± 0.045°F). Thermometer accuracy from 0°C to 150°C (32ºF to 302°F): ± 0.05°C (± 0.09°F). Calibration uncertainty: ± 0.0047°C (± 0.00846°F). The accuracy shall be checked against a thermometer which has been tested by or is traceable to NIST. This calibration shall be performed annually by a properly trained representative of an “Official Laboratory” or an “Officially Designated Laboratory”; or by a qualified representative of a thermometer manufacturer; or by a properly trained Health Officer. The calibration protocol/SOP shall be developed by the Health Officer in cooperation with the thermometer manufacturer and FDA. Documentation of the identity of the properly trained Health Officer shall be maintained by the Health Officer. A signed certificate of calibration for the digital thermometer shall be maintained with the unit.
Self-Diagnostic Circuitry: Circuitry shall provide constant monitoring of all sensing, input, and conditioning circuits. The diagnostic circuitry should be capable of identifying the probe and its calibration information. Without a correct connection of the probe, the display shall alert the operator and no temperature will be displayed.
Electro-magnetic Compatibility: Shall be documented for these devices for their intended use and available to the Health Officer. Units to be used in the “field” shall have been tested for heavy industrial standards, as specified in the European Electromagnetic Compatibility Directive.
Immersion: Minimum immersion point shall be marked on the probe. During control tests, the probes shall be immersed to equal depths in a water or oil bath.
Case: Suitable to provide protection during transit and periods when not in use.
GENERAL PURPOSE THERMOMETER
Type: Pocket type.
Scale Range: 1°C (30°F) to 100°C (212°F), with extensions of the scale on either side permitted. Protected against damage at 105°C (220°F).
Temperature Represented by Smallest Scale Division: 1°C (2°F).
Accuracy: Within ± 1°C (± 2°F), throughout the specified scale range. Checked periodically against a known accurate thermometer.
In the case of mercury actuated general-purpose thermometers, the following additional specifications shall apply:
Magnification of Mercury Column: To apparent width of not less than 1.6 millimeter (0.0625 of an inch).
Number of Degrees per Inch of Scale: Not more than 29°C or not more than 52°F.
Case: Metal, provided with a fountain pen clip.
Bulb: Corning normal or equally suitable thermometric glass.
ELECTRICAL CONDUCTIVITY MEASURING DEVICES
Type: Manual or automatic.
Conductivity: Capable of detecting change produced by the addition of ten (10) ppm of sodium chloride, in water of 100 ppm of hardness.
Electrodes: Standard.
Automatic Instruments: Electric clock, time divisions not over 0.2 of a second.
TIME MEASURING DEVICE
An accurate time measuring device may include but is not limited to a stopwatch, digital watch, conductivity device timer, and any other device which keeps time accurately.
STOPWATCH
Type: Open face, indicating fractional seconds.
Accuracy: Accurate to 0.2 of a second.
Hands: Sweep hand, if applicable, one complete turn every sixty (60) seconds or less.
Scale: Divisions of not over 0.2 of a second.
Crown: Depression of crown or push button starts, stops, and resets to zero.
II. TEST PROCEDURES
Pasteurization equipment tests listed and referenced below shall be performed by the Health Officer; or in the case of HACCP listed milk plants, qualified industry personnel, acceptable to the Health Officer, as cited in Rule 420-3-16-.10(21-22); or on an emergency basis, an industry temporary testing and sealing program, authorized by the Health Officer, as cited in Rule 420-3-16-.10(21-22). The results of the tests shall be recorded on appropriate forms and filed as the Health Officer shall direct (refer to Appendix M of these rules). Regulatory seals shall be installed where required at the commissioning of a new pasteurization system. If the public health control(s) is within a computer system used to manage the functions of the public health control device(s) that operate the pasteurization system, the computer shall be in compliance with Appendix H, VI of these rules before the access to the computer program is sealed. Whenever a regulatory seal has been broken, the pasteurization equipment shall be re-sealed after the appropriate testing has been conducted by the Health Officer or qualified industry personnel in compliance with Rule 420-3-16-.10(21-22) and are found to be in compliance with the applicable test procedure(s).
Note: If the pasteurization system fails one (1) or more of the required tests, the pasteurization system shall not be allowed to operate until the cause of this failure has been corrected and compliance has been verified by the Health Officer; or in the case of HACCP listed milk plants, qualified industry personnel acceptable to the Health Officer in compliance with Rule 420-3-16-.10(21-22); or on an emergency basis, an industry temporary testing and sealing program, authorized by the Health Officer in compliance with Rule 420-3-16-.10(21-22).
If it is required to break a regulatory seal to conduct any of the following tests, it shall be replaced by the Health Officer or HACCP qualified personnel acceptable to the Health Officer after testing has been completed and compliance has been
Note: For various pieces of equipment approved for pasteurization systems, testing procedures which have been reviewed specifically for that equipment are included within the FDA accepted operations manual for the equipment and/or within the Memorandum of Milk Ordinance Equipment Compliance (M-b) issued upon FDA’s review and acceptance of the equipment. These testing procedures shall be used.
TEST 1
INDICATING THERMOMETERS - TEMPERATURE ACCURACY
Reference: Rule 420-3-16-.10(17-18) and Rule 420-3-16-.10(21-22)
Application: To all indicating thermometers, including airspace thermometers if applicable, used for the measurement of milk and/or milk product temperature during pasteurization and/or ultra-pasteurization. Do not run this test if the liquid column has been split or the capillary tube is broken.
Frequency: Upon installation; at least once each three (3) months thereafter; whenever the thermometer has been repaired and/or replaced; or whenever the regulatory seal on a digital sensing element or a digital control box has been broken.
Criteria: Within ± 0.25ºC (± 0.5ºF) for pasteurization and ultra-pasteurization indicating thermometers and ± 0.5ºC (± 1ºF) for airspace thermometers, in a specified scale range; provided, that on a batch pasteurizer used solely for thirty (30) minute pasteurization of milk and/or milk products at temperatures above 71°C (160°F), the indicating thermometer shall be accurate to within ± 0.5°C (± 1°F).
Apparatus:
-
Test thermometer meeting the specifications cited in Section I of this appendix.
-
Water, oil or other suitable media bath and agitator.
-
Suitable means of heating the media bath.
Method: Both the indicating and/or airspace thermometer, if applicable, and test thermometer shall be exposed to water, oil, or other suitable media of a uniform temperature. The indicating thermometer and/or airspace thermometer, if applicable, reading is compared to the reading of the test thermometer.
Procedure:
-
Prepare a media bath by raising the temperature of the media to within 2°C (3°F) of the lowest sealed cut-out pasteurization or ultra-pasteurization temperature or minimum legal indicating or airspace temperature for batch pasteurization.
-
Stabilize the media bath temperature and agitate rapidly.
-
Continue agitation and insert the indicating and/or airspace thermometer, if applicable, and test thermometer to the indicated immersion point.
-
Compare the thermometer readings at a temperature within the test range.
-
Repeat the comparison of the thermometer readings.
-
If the results of this test are outside the Criteria noted above, the indicating thermometer or airspace thermometer, if applicable, shall be adjusted by milk plant personnel to agree with the test thermometer, retest and record the action taken on the appropriate form.
-
When compliance is achieved and/or verified, record the thermometer readings from both comparisons and record the thermometer identification or location on the appropriate form.
-
Re-seal as appropriate the sensing elements and control boxes of the digital thermometers.
Action: If the pasteurization or ultra-pasteurization system fails this test, the pasteurization or ultra-pasteurization system shall not be allowed to operate until the cause of this failure has been corrected and compliance has been verified by the Health Officer; or in the case of HACCP listed milk plants, qualified industry personnel, acceptable to the Health Officer, in compliance with Rule 420-3-16-.10(21-22) or on an emergency basis, an industry temporary testing and sealing program authorized by the Health Officer in compliance with Rule 420-3-16-.10(21-22).
TEST 2
TEMPERATURE RECORDING AND RECORDER-CONTROLLER THERMOMETERS - TEMPERATURE ACCURACY
Reference: Rule 420-3-16-.10(17-18) and Rule 420-3-16-.10(21-22)
Application: To all temperature recording and recorder-controller thermometers used to record milk and/or milk product temperatures during pasteurization and/or ultra-pasteurization, except those which are electronic or computer controlled.
Frequency: Upon installation; at least once each three (3) months thereafter; whenever the sensing element has been repaired and/or replaced; or whenever the regulatory seal has been broken.
Criteria: Within ± 0.5°C (± 1°F), in a specified scale range as described in Procedure 1 below; provided, that on a batch pasteurizer used solely for thirty (30) minute pasteurization of milk and/or milk products at temperatures above 71°C (160°F), the temperature recording thermometer shall be accurate to within ± 1°C (± 2°F) between 71°C (160°F) and 77°C (170°F).
Apparatus:
-
The indicating thermometer which was previously tested against a known accurate test thermometer.
-
Water, oil, or other suitable media bath and agitator.
-
Suitable means of heating the media bath.
-
Ice.
Note: When this test is performed on temperature recorder-controllers used with HHST pasteurization systems that operate at or above the boiling point of water, an oil or other suitable media bath shall be substituted for the processing (operating) temperature water mentioned in Procedures 1, 4, 5, 6, and 7 as well as the boiling water mentioned in Procedures 2, 3 and 5. The temperature of the oil bath that is used in place of the boiling water shall be above the normal operating range but below the highest temperature division on the chart.
Method: The testing of a temperature recording or recorder-controller thermometer for temperature accuracy involves the determination of whether or not the temperature pen-arm will return to within ± 0.5ºC (± 1ºF) or ± 1°C (± 2°F) as provided for in the Criteria above, of its previous setting, after exposure to high heat and melting ice.
Procedure:
- Heat a media bath to a constant temperature utilizing one (1) of the following temperatures:
a. Lowest sealed cut-out pasteurization temperature; or
b. Minimum legal indicating or airspace pasteurization temperature for batch pasteurization; provided, that on a batch pasteurizer used solely for thirty (30) minute pasteurization of milk and/or milk products at temperatures above 71°C (160°F), this test shall be conducted with a media bath temperature above 71°C (160°F) and below 77°C (170°F).
Immerse the temperature recording or recorder-controller thermometer sensing element into the media bath. After a stabilization period of five (5) minutes, if necessary adjust the temperature re-cording or recorder-controller thermometer pen to read exactly as the previously tested indicating thermometer. The media bath shall be rapidly agitated throughout this stabilization period.
-
Prepare a second media bath by heating the media bath to the boiling point of water, or in the case of HHST pasteurization systems, to a temperature above the normal operating range but below the highest temperature division on the chart, and maintain temperature. Prepare a third media bath with ice and water. Place all media baths within working distance of the temperature recording or recorder-controller thermometer temperature-sensing element(s).
-
Immerse the temperature recording or recorder-controller thermometer sensing element into the hotmedia bath as prepared in Procedure 2, above, for not less than five (5) minutes.
-
Remove the temperature recording or recorder-controller thermometer sensing element from the hot media bath and immerse it in the media bath as prepared in Procedure 1 above. Allow a five (5) minute stabilization period for both the indicating and temperature recording or recorder-controller thermometers. Compare the readings of the indicating and temperature recording or recorder-controller thermometers. The temperature recording or recorder-controller thermometer reading shall be within ± 0.5ºC (± 1ºF) or ± 1°C (± 2°F) as provided for in the Criteria above, of the indicating thermometer reading.
-
Remove the temperature recording or recorder-controller thermometer sensing element from the media bath in the temperature range for the process being used and immerse it in the ice and water bath for not less than five (5) minutes.
-
Remove the temperature recording or recorder-controller thermometer sensing element from the ice and water bath and immerse it in the media bath as prepared in Procedure 1 above. Allow a five (5) minute stabilization period for both the indicating and temperature recording or recorder-controller thermometers. Compare the readings of the indicating and temperature recording or recorder-controller thermometers. The temperature recording or recorder-controller thermometer reading shall be within ± 0.5°C (± 1°F) or ± 1°C (± 2°F) as provided for in the Criteria above, of the indicating thermometer reading.
-
When compliance is achieved and/or verified, re-seal the thermometer sensing elements and recorder-controller as necessary and record the indicating and temperature recording thermometer or recorder-controller thermometer readings obtained from Procedures 1, 4, and 6 above on the appropriate form.
Action: If the temperature recording or recorder-controller thermometer pen does not return to ± 0.5°C (± 1°F) or ± 1°C (± 2°F) as provided in Procedures 4 and 6 above, the temperature recording or recorder-controller thermometer shall be repaired or replaced by milk plant personnel. If the pasteurization or ultra-pasteurization system fails this test, the pasteurization or ultra-pasteurization system shall not be allowed to operate until the cause of this failure has been corrected and compliance has been verified by the Health Officer; or in the case of HACCP listed milk plants, qualified industry personnel acceptable to the Health Officer in compliance with Rule 420-3-16-.10(21-22); or on an emergency basis, an industry temporary testing and sealing program authorized by the Health Officer in compliance with Rule 420-3-16-.10(21-22).
TEST 3
TEMPERATURE RECORDING AND RECORDER-CONTROLLER THERMOMETERS - TIME ACCURACY
Reference: Rule 420-3-16-.10(17-18) and Rule 420-3-16-.10(21-22)
Application: To all temperature recording and recorder-controller thermometers used to record the time of pasteurization and/or ultra-pasteurization.
Frequency: Upon installation; at least once each three (3) months thereafter; whenever the temperature recorder-controller thermometer or programmable recording thermometer has been repaired and/or replaced; or whenever the regulatory seal on a temperature recorder-controller thermometer or programmable recording thermometer or sensing element has been broken.
Criteria: The recorded time of pasteurization or ultra-pasteurization shall not exceed the true elapsed time.
Apparatus: An accurate time measuring device.
Method: A comparison of the recorded time over a period of not less than thirty (30) minutes with an accurate time measuring device.
Procedure:
-
Determine if the recording chart is appropriate for the temperature recording or recorder-controller thermometer. Ensure that the recording chart pen is aligned with the time arc of the recording chart at both the center and the outside edge.
-
Inscribe a reference mark at the pen point on the recording chart and record the time.
-
At the end of thirty (30) minutes utilizing an accurate time measuring device, inscribe a second reference mark at the pen point position on the recording chart.
-
Determine the distance between the two (2) reference marks and compare the distance with the time-scale divisions on the recording chart at the same temperature.
-
Re-seal the sensing elements and recorder-controller as necessary; enter the results on the recording chart and initial the recording chart; and record the beginning and ending times on the appropriate Form.
Action: If the recorded time is incorrect, the temperature recording or recorder-controller thermometer device shall be adjusted or repaired by milk plant personnel. If the pasteurization or ultra-pasteurization system fails this test, the pasteurization or ultra-pasteurization system shall not be allowed to operate until the cause of this failure has been corrected and compliance has been verified by the Health Officer; or in the case of HACCP listed milk plants, qualified industry personnel acceptable to the Health Officer in compliance with Rule 420-3-16-.10(21-22); or on an emergency basis, an industry temporary testing and sealing program authorized by the Health Officer in compliance with Rule 420-3-16-.10(21-22).
TEST 4
TEMPERATURE RECORDING AND RECORDER-CONTROLLER THERMOMETERS - CHECKED AGAINST INDICATING THERMOMETER
Reference: Rule 420-3-16-.10(17-18) and Rule 420-3-16-.10(21-22)
Application: To all temperature recording and recorder-controller thermometers used to record milk and/or milk product temperatures during pasteurization or ultra-pasteurization, and for batch pasteurizer digital combination airspace/recording thermometers with a continuous recording of the airspace temperature and where the airspace temperature is read and recorded on the recording chart only at the start of the pasteurization holding period.
Frequency: Upon installation; at least once each three (3) months thereafter; whenever the temperature recording or recorder-controller thermometer has been repaired and/or replaced; whenever the regulatory seal has been broken; and daily and immediately after a recording chart has been changed by milk plant personnel.
Criteria: The temperature recording thermometer and recorder-controller thermometer shall not read higher than the indicating or airspace thermometer which were previously tested against a known accurate test thermometer.
Apparatus: No supplementary materials required.
Method: This test requires only that the reading of the temperature recording thermometer, recorder-controller thermometer, or airspace recording thermometer be compared with the indicating thermometer at a time when both are exposed to a stabilized temperature at or above the minimum legal pasteurization temperature.
Procedure:
-
When the indicating and temperature recording or recorder-controller thermometer temperature readings are stabilized at or above the minimum legal pasteurization temperature, read the indicating thermometer.
-
For batch pasteurizers, when the airspace indicating and recording temperature readings are stabilized at or above the minimum legal pasteurization temperature, read the airspace thermometer.
-
Immediately enter the results; the time at which this comparison was made; and initial the recording chart. This may be accomplished by inscribing a line intersecting the recorded temperature arc at the pen location or any other method acceptable to the Health Officer.
-
Record the observed indicating and temperature recording thermometer or recorder-controller thermometer readings on the appropriate form.
Action: If the temperature recording thermometer or recorder-controller thermometer reads higher than the indicating thermometer, the pen or temperature adjusting mechanism shall be adjusted by milk plant personnel to agree with the indicating thermometer. If after adjustment the temperature recording thermometer or recorder-controller thermometer fails this test, the pasteurization or ultra-pasteurization system shall not be allowed to operate until the cause of this failure has been corrected and compliance has been verified by the Health Officer; or in the case of HACCP listed milk plants, qualified industry personnel acceptable to the Health Officer in compliance with Rule 420-3-16-.10(21-22), or on an emergency basis, an industry temporary testing and sealing program authorized by the Health Officer in compliance with Rule 420-3-16-.10(21-22).
TEST 5
FDD - PROPER ASSEMBLY AND FUNCTION
Reference: Rule 420-3-16-.10(18); Rule 420-3-16-.10(21-22)
Application: 5.1 to 5.4 and 5.6 to 5.8 below apply to all FDDs used with continuous-flow pasteurization systems. 5.5 and 5.9 below apply only to FDDs used with HTST pasteurization systems.
Frequency: Upon installation; at least once each three (3) months thereafter; whenever the FDD has been repaired and/or replaced; or whenever the regulatory seal(s) has been broken.
Criteria: The FDD shall function as required in all operating situations and shall de-energize the timing pump and all other flow-promoting devices capable of causing flow through the FDD, in the event of a FDD malfunction or when the FDD is incorrectly assembled.
5.1 LEAKAGE PAST THE VALVE SEAT(S)
Apparatus: Suitable tools for the disassembly of the FDD and any connected sanitary piping.
Method: Observe the valve seat(s) for leakage.
Procedure:
- With the pasteurization system operating on water, place the FDD in the diverted-flow position.
a. For single stem FDDs, disconnect the forward-flow sanitary piping and observe the valve seat for leakage. Check the leak escape ports to see if they are open; or
b. For dual stem FDDs, observe the leak-detect line discharge or sight glass for leakage.
- Record the results of the test on the appropriate form.
Action: If leakage is observed, suitable repairs shall be made to the FDD by milk plant personnel. If after adjustment and/or repair the FDD fails this test, the pasteurization system shall not be allowed to operate until the cause of this failure has been corrected and compliance has been verified by the Health Officer; or in the case of HACCP listed milk plants, qualified industry personnel acceptable to the Health Officer in compliance with Rules 420-3-16-.10(21-22); or on an emergency basis, an industry temporary testing and sealing program authorized by the Health Officer in compliance with Rules 420-3-16-.10(21-22).
5.2 OPERATION OF THE VALVE STEM(S)
Apparatus: Suitable tools for tightening the packing nut on the valve stem of a single stem FDD.
Method: Observe the valve stem(s) for ease of movement.
Procedure:
-
For single stem FDDs, tighten the valve stem packing nut as much as possible. Operate the pasteurization system at maximum operating pressure and place the FDD in both forward and diverted-flow several times. The valve stem shall move freely in both forward and diverted-flow positions when the stem-packing nut is fully tightened. Note the freedom of action of the valve stem.
-
For dual stem FDDs, operate the pasteurization system at maximum operating pressure and place the FDD in both forward and diverted-flow several times. The valve stems shall move freely in both forward and diverted-flow positions. Note the freedom of action of the valve stems.
-
Record the results of the test on the appropriate form.
Action: If the valve stem(s) action is sluggish, suitable adjustment or repair shall be made by milk plant personnel. If after adjustment and/ pasteurization system shall not be allowed to operate until the cause of this failure has been corrected and compliance has been verified by the Health Officer; or in the case of HACCP listed milk plants, qualified industry personnel acceptable to the Health Officer in compliance with Rule 420-3-16-.10(21-22); or on an emergency basis, an industry temporary testing and sealing program authorized by the Health Officer in compliance with Rule 420-3-16-.10(21-22).
5.3 DEVICE ASSEMBLY - SINGLE STEM FDD
Apparatus: Suitable tools for the disassembly of the FDD and any connected sanitary piping.
Method: When the FDD is improperly assembled and in diverted-flow, below the cut-out temperature, observe the function of the timing pump and all other flow-promoting devices capable of causing flow through the FDD.
Procedure:
-
With the pasteurization system in operation, in “Process” mode, and below the cut-in temperature, unscrew by one-half (1/2) turn, the 13H hex nut that holds the top of the valve to the valve body. This shall de-energize the timing pump and all other flow-promoting devices which are capable of causing flow through the FDD. In addition, separators and/or downstream vacuum sources shall be effectively valved-out of the pasteurization system. This test shall be conducted without any sanitary piping connected to the forward-flow port of the FDD. This allows for the movement of the top of the valve when the hex nut is loosened. Re-tighten the 13H hex nut.
-
With the pasteurization system in operation, in “Process” mode, and below the cut-in temperature, remove the connecting key which is located at the base of the valve stem. The timing pump and all other flow-promoting devices which are capable of causing flow through the FDD shall be de-energized. In addition, separators and/or downstream vacuum sources shall be effectively valved-out of the pasteurization system.
-
Attempt to restart each flow-promoting device capable of causing flow through the FDD. None of these flow-promoting devices shall start or operate. Separators and/or downstream vacuum sources shall remain effectively valved-out of the pasteurization system.
-
Record the results of the test on the appropriate form.
Action: If any flow-promoting device fails to respond as indicated above, an immediate check of the FDD assembly and wiring is required by milk plant personnel to locate and correct the cause of the failure. If after adjustment and/or repair the FDD fails this test, the pasteurization system shall not be allowed to operate until the cause of this failure has been corrected and compliance has been verified by the Health Officer; or in the case of HACCP listed milk plants, qualified industry personnel acceptable to the Health Officer in compliance with Rule 420-3-16-.10(21-22); or on an emergency basis, an industry temporary testing and sealing program authorized by the Health Officer in compliance with Rule 420-3-16-.10(21-22).
5.4 DEVICE ASSEMBLY - DUAL STEM DEVICE
Note: the test procedure presented in this section is typical of tests accepted by FDA for various specific types of FDDs. Testing details, which may vary, are provided in individual FDD operator’s manuals that have been reviewed by the FDA and are specified by part number in FDA’s M-bs. In each of these M-b accepted test methods, if the words "metering pump" or "timing pump" are used they shall be understood to mean "timing pump and all other flow-promoting devices, which are capable of causing flow through the FDD.”
Apparatus: No supplementary materials required.
Method: Observe the function of the timing pump and all other flow-promoting devices which are capable of causing flow through the FDD when the FDD is improperly assembled.
Procedure:
-
With the FDD in diverted-flow caused by temperature, and the FDD is properly assembled, move the FDD to the forward-flow position by moving the switch to the “Inspect” mode and disconnect the valve stem from the actuator of the valve being tested.
-
Move the FDD to the diverted-flow position by moving the switch to the “Product” mode and turn on the timing pump and all other flow-promoting devices which are capable of causing flow through the FDD. The timing pump and all other flow-promoting devices shall be de- energized and shall not run. If any flow-promoting device which is capable of causing flow through the FDD starts momentarily and then stops running, it may indicate the improper wiring of the one (1) second time delay as allowed for in 16p.(B)2.b.(10). In addition, separators and/or downstream vacuum sources shall remain effectively valved-out of the pasteurization system. Move the switch to the “Inspect” mode and properly reassemble the FDD. Start the timing pump and all other flow-promoting devices which are capable of causing flow through the FDD to determine if the FDD has been properly reassembled.
-
Repeat this procedure for the other actuator.
-
Record the results of the test on the appropriate form.
Action: If any of the flow-promoting devices which are capable of causing flow through the FDD fail to respond as indicated, an immediate check of the FDD assembly and wiring shall be conducted by milk plant personnel to locate and correct the problem. If after adjustment and/or repair the FDD fails this test, the pasteurization system shall not be allowed to operate until the cause of this failure has been corrected and compliance has been verified by the Health Officer; or in the case of HACCP listed milk plants, qualified industry personnel acceptable to the Health Officer in compliance with Rule 420-3-16-.10(21-22); or on an emergency basis, an industry temporary testing and sealing program authorized by the Health Officer in compliance with Rule 420-3-16-.10(21-22).
5.5 MANUAL DIVERSION
Apparatus: No supplementary materials required.
Method: Observe that the appropriate responses in Procedures 1 and 2, as required below, have occurred during the activation and deactivation of manual diversion.
Procedure:
- With the HTST pasteurization system in operation and the FDD in the forward-flow position, activate the manual divert control.
a. The FDD shall assume the diverted-flow position.
b. Any flow-promoting device downstream from the FDD, which is capable of causing flow through the FDD shall be de-energized.
c. Any separator and/or vacuum source downstream from the FDD shall be effectively valved-out.
- If a booster pump is installed in the HTST pasteurization system and the pasteurization system is in operation with the FDD in the forward-flow position:
a. Activate the manual divert control. The booster pump shall be de-energized. The required minimum pressure differential of at least 6.9 kPa (1 psi) between raw milk and/or milk product and pasteurized milk and/or milk product in the regenerator shall be maintained.
b. After the raw pressure reaches zero (0) psi, deactivate the manual divert control and observe that the required minimum pressure differential of at least 6.9 kPa (1 psi) between raw milk and/or milk product and pasteurized milk and/or milk product in the regenerator has been maintained.
Action: If the above described required actions do not occur, or the required pressure differential between raw and pasteurized milk and/or milk product is not maintained, the HTST pasteurization system shall be immediately reviewed and evaluated by milk plant personnel and the indicated deficiencies corrected or proper adjustments made. If after adjustment and/or repair the FDD fails this test, the pasteurization system shall not be allowed to operate until the cause of this failure has been corrected and compliance has been verified by the Health Officer; or in the case of HACCP listed milk plants, qualified industry personnel acceptable to the Health Officer in compliance with Rule 420-3-16-.10(21-22); or on an emergency basis, an industry temporary testing and sealing program authorized by the Health Officer in compliance with Rule 420-3-16-.10(21-22).
5.6 RESPONSE TIME
Apparatus:
-
Water, oil or other suitable media bath and agitator.
-
Suitable means of heating the media bath.
-
An accurate time measuring device.
Method: Determine that the elapsed time does not exceed one (1) second between the instant of the activation of the FDD control mechanism at cut-out temperature, on declining temperature, and the instant the FDD takes the fully diverted-flow position.
Procedure:
-
With the water, oil, or suitable media bath at a temperature above cut-out temperature, allow the water, oil, or other suitable media to cool gradually. The moment the cut-out mechanism is activated, start the accurate time measuring device. The moment the FDD takes the fully-diverted position, stop the accurate time measuring device.
-
Record the results of the test on the appropriate form.
Action: If the response time exceeds one (1) second, immediate action shall be taken by milk plant personnel to correct this FDD deficiency. If after adjustment and/or repair the FDD fails this test, the pasteurization system shall not be allowed to operate until the cause of this failure has been corrected and compliance has been verified by the Health Officer; or in the case of HACCP listed milk plants, qualified industry personnel acceptable to the Health Officer in compliance with Rule 420-3-16-.10(21-22); or on an emergency basis, an industry temporary testing and sealing program authorized by the Health Officer in compliance with Rule 420-3-16-.10(21-22).
5.7 TIME DELAY INTERLOCK WITH TIMING PUMP AND OTHER FLOW PROMOTING DEVICES
Application: To all dual stem FDDs with a manual forward-flow control switch.
Apparatus: No supplementary materials required.
Method: Determine that the FDD does not assume a manually induced forward-flow position while the timing pump or any other flow-promoting device which is capable of causing flow through the FDD is operating.
Procedure: With the pasteurization system operating in forward-flow, move the control switch to the "Inspect" position and observe that the following events automatically occur in sequence:
-
The FDD immediately moves to the diverted-flow position and the timing pump and all other flow-promoting devices, which are capable of causing flow through the FDD, are de-energized, or in the case of separators and/or downstream vacuum sources, are effectively valved-out of the pasteurization system.
-
The FDD remains in the diverted-flow position until the timing pump and all other flow-promoting devices which are capable of causing flow through the FDD have completely stopped running or in the case of a separator and/or downstream vacuum sources, are effectively valved-out of the pasteurization system.
-
Then the FDD shall assume the forward-flow position.
-
Record the results of the test on the appropriate form and seal the control enclosure.
Action: If the above sequence of events do not occur, either a timer adjustment or wiring change is required to be made by pasteurization plant personnel. If after adjustment and/or repair the FDD fails this test, the pasteurization system shall not be allowed to operate until the cause of this failure has been corrected and compliance has been verified by the Health Officer; or in the case of HACCP listed milk plants, qualified industry personnel acceptable to the Health Officer in compliance with Rule 420-3-16-.10(21-22); or on an emergency basis, an industry temporary testing and sealing program authorized by the Health Officer in compliance with Rule 420-3-16-.10(21-22).
5.8 CIP TIME DELAY RELAY
Application: To all continuous-flow pasteurization systems in which it is desired to run any flow-promoting devices during the CIP cycle.
Criteria: When the mode switch on the FDD is moved from “Process” to “CIP,” the FDD shall move immediately to the diverted-flow position. It shall remain in the diverted-flow position for at least ten (10) minutes, with all public health controls required in the “Process” mode functioning, before starting its normal cycling in the “CIP” mode. In HTST pasteurization systems, the booster pump shall be de-energized, separators between raw regenerator sections and separators and/or vacuum sources downstream of the FDD shall be effectively valved-out of the pasteurization system during the required ten (10) minute time delay.
Apparatus: An accurate time measuring device.
Method: Determine that the set point on the “CIP” time delay is equal to or greater than the required ten (10) minutes by observing the time when the FDD moves to the forward-flow position or is again capable of moving to the forward-flow position.
Procedure:
- Operate the pasteurization system in forward-flow, with the mode switch on the FDD controls in the “Process” position, using water above the minimum legal pasteurization temperature. For magnetic flow meter based timing systems, operate the system at a flow-rate below the flow alarm set point and above the low-flow or loss-of-signal alarm set point.
Note: The appropriate temperature sensing elements may be placed in a water, oil, or other suitable media bath to simulate the normal pasteurization temperature within the holding tube as an alternative to heating the water in the pasteurization system above the minimum legal pasteurization temperature.
-
Move the mode switch on the FDD control to the “CIP” position. The FDD shall move immediately to the diverted-flow position. Start the accurate time measuring device when the FDD moves to the diverted-flow position. Confirm that all public health controls required in diverted flow in the “Process” mode are functioning.
-
Stop the accurate time measuring device when the FDD moves to the forward-flow position or is again capable of moving to the forward-flow position. At this time, the pasteurization system may be operated without the FDD controls normally required during the “Process” mode during product processing.
-
Record the results of the test on the appropriate form.
-
Re-seal the regulatory enclosure over the time delay.
Action: If the FDD does not remain in the diverted-flow position for at least the required ten (10) minutes after the FDD mode switch is moved from “Process” to “CIP,” increase the set point on the time delay and repeat this test procedure. All public health controls required when the pasteurization system is in “Process” mode and in diverted-flow shall be functional during this required ten (10) minutes. If the above does not occur, either a timer adjustment or wiring change is required to be made by milk plant personnel. If after adjustment and/or repair the FDD fails this test, the pasteurization system shall not be allowed to operate until the cause of this failure has been corrected and compliance has been verified by the Health Officer; or in the case of HACCP listed milk plants, qualified industry personnel acceptable to the Health Officer in compliance with Rule 420-3-16-.10(21-22); or on an emergency basis, an industry temporary testing and sealing program authorized by the Health Officer in compliance with Rule 420-3-16-.10(21-22).
5.9 LEAK-DETECT VALVE FLUSH - TIME DELAY
Application: To HTST continuous-flow pasteurization systems in which the space between the divert and leak-detect valves is not self-draining when the FDD is in the diverted-flow position.
Criteria: The space between the divert and leak-detect valves shall be flushed for at least one (1) second and not more than five (5) seconds after the divert valve moves to the forward-flow position and before the leak-detect valve moves to the forward-flow position.
The maximum of five (5) seconds delay is not applicable if:
-
The minimum acceptable pasteurization holding time in diverted-flow can be achieved without the use of any restriction in the divert line; or
-
The timing system is magnetic flow meter based.
Apparatus: An accurate time measuring device.
Method: Observe the movement of the divert and leak-detect valves to the forward-flow position and measure the time interval between the movement of the two (2) valves.
Procedure:
- Move the FDD from the diverted-flow position to the forward-flow position either by:
a. Raising the temperature above the cut-in set point; or
Note: The appropriate temperature sensing elements may be placed in a water, oil, or other suitable media bath to simulate the normal pasteurization temperature within the holding tube as an alternative to heating the water in the pasteurization system above the minimum legal pasteurization temperature.
b. Operating the HTST pasteurization system above the cut-in temperature in manual divert mode and then deactivate the manual divert control.
-
When the divert valve begins to move to the forward-flow position, start the accurate time measuring device.
-
When the leak-detect valve begins to move to the forward-flow position, stop the accurate time measuring device.
-
Record the elapsed time on the appropriate form.
-
If the elapsed time is at or above one (1) second and at or below five (5) seconds, except as noted in the exceptions in the Criteria above, seal the time delay as required.
Action: If the elapsed time is less than one (1) second or greater than five (5) seconds, except as noted in the exceptions in the Criteria above, appropriate changes to the pasteurization system or pasteurization system’s FDD controls shall be made by milk plant personnel. If after adjustment and/or repair the FDD fails this test, the pasteurization system shall not be allowed to operate until the cause of this failure has been corrected and compliance has been verified by the Health Officer; or in the case of HACCP listed milk plants, qualified industry personnel acceptable to the Health Officer in compliance with Rule 420-3-16-.10(21-22); or on an emergency basis, an industry temporary testing and sealing program authorized by the Health Officer in compliance with Rule 420-3-16-.10(21-22).
TEST 6
BATCH (VAT) PASTEURIZER LEAK-PROTECTOR OUTLET VALVE
Reference: Rule 420-3-16-.10(17) and Rule 420-3-16-.10(21-22)
Application: To all batch (vat) pasteurizers that have an outlet valve.
Frequency: Upon installation; and at least once each three (3) months thereafter.
Criteria: No leakage past the outlet valve seat in the closed position.
Apparatus: No supplementary materials required.
Method: By observing whether or not leakage past the outlet valve seat occurs when pressure is exerted against the upstream face of the outlet valve.
Procedure:
-
Utilizing milk, milk products, or water, fill the batch (vat) pasteurizer to the normal operation level.
-
Observe the outlet valve in the closed position and determine whether or not milk, milk product, or water, respectively, is leaking past the outlet valve seat into the valve outlet.
-
Record the results of the test on the appropriate form.
Action: If leakage past the outlet valve seat occurs in the closed position, the outlet valve plug shall be repaired or replaced by milk plant personnel. If the outlet valve fails this test, the batch (vat) pasteurizer shall not be allowed to operate until the cause of this failure has been corrected and compliance has been verified by the Health Officer; or in the case of HACCP listed milk plants, qualified industry personnel acceptable to the Hea
420-3-16-.10(21-22); or on an emergency basis, an industry temporary testing and sealing program authorized by the Health Officer in compliance with Rules 420-3-16-.10(21-22).
TEST 7
INDICATING THERMOMETERS LOCATED WITHIN HTST PASTEURIZATION SYSTEMS - THERMOMETRIC RESPONSE
Reference: Rule 420-3-16-.10(18) and Rule 420-3-16-.10(21-22)
Application: To all HTST pasteurization systems, except for those in which the FDD is located downstream of the pasteurized regenerator section(s) and/or the final cooler section.
Frequency: Upon installation; at least once each three (3) months thereafter; whenever the indicating thermometer has been repaired and/or replaced; or whenever the regulatory seal on a digital sensing element or digital control box has been broken.
Criteria: Four (4) seconds or less.
Apparatus:
-
Accurate time measuring device.
-
The indicating thermometer, which was previously tested against a known accurate test thermometer.
-
Water, oil or other suitable media bath and agitator.
-
Suitable means of heating the media bath.
-
Ice and water media bath.
Method: The measuring of the time required for the reading of the indicating thermometer being tested to increase 7°C (12°F) through a specified temperature range. This temperature range shall include the minimum legal pasteurization temperature(s). If there are multiple cut-in temperatures and one (1) or more are separated by more than 7°C (12°F), this test shall also be conducted for any cut-in temperature(s) not included within the initial 7°C (12°F) range as addressed in Procedure 1 below.
Procedure:
-
Immerse the indicating thermometer in the media bath which has been heated to a temperature at least 11°C (19°F) higher than the minimum scale reading on the indicating thermometer. The media bath temperature shall be 4°C (7°F) higher than the highest pasteurization temperature set point (cut-in temperature) for which the indicating thermometer is being used.
-
Immerse the indicating thermometer in an ice and water media bath for several seconds to cool it.
Note: Continuous agitation of the heated media bath during the performance of Procedures 3, 4 and 5 is required. The elapsed time between the end of Procedure 1 and the beginning of Procedure 3 shall not exceed fifteen (15) seconds, unless a constant temperature media bath is used to prevent the heated media bath from cooling significantly.
-
Insert the indicating thermometer into the heated media bath to the proper indicating thermometer bulb immersion depth.
-
Start the accurate time measuring device when the indicating thermometer reads 11°C (19°F) below the heated media bath temperature.
-
Stop the accurate time measuring device when the indicating thermometer reads 4°C (7°F) below the heated media bath temperature.
-
Record the results of the test on the appropriate form.
For Example: For an indicating thermometer used at pasteurization temperature set points of 71.7°C (161°F) and 74.4°C (166°F), a media bath at a temperature of 78.3°C (173°F) could be used. 11°C (19°F) lower than a 78.3°C (173°F) media bath would be 67.8°C (154°F); 4°C (7°F) lower than a 78.3°C (173°F) media bath would be 74.4°C (166°F). Hence, after immersing the indicating thermometer that has been previously cooled in the ice and water media bath into the 78.3°C (173°F) bath, the accurate time measuring device is started when the thermometer reads 67.8°C (154°F) and the accurate time measuring device is stopped when it reads 74.3°C (166°F).
Note: The example included the pasteurization temperature set points of 71.7°C (161°F) and 74.4°C (166°F). If the pasteurization temperature set points had been 71.7°C (161°F) and 79.4°C (175°F), it would not have been possible to include both set points within a 7°C (12°F) span. With these set points of 71.7°C (161°F) and 79.4°C (175°F), the test would have to be conducted separately for each set point.
Action: If the response time exceeds four (4) seconds, the indicating thermometer shall be repaired or replaced by milk plant personnel. If the thermometer fails this test, the pasteurization system shall not be allowed to operate until the cause of this failure has been corrected and compliance has been verified by the Health Officer; or in the case of HACCP listed milk plants, qualified industry personnel acceptable to the Health Officer in compliance with Rule 420-3-16-.10(21-22); or on an emergency basis, an industry temporary testing and sealing program authorized by the Health Officer in compliance with Rule 420-3-16-.10(21-22).
TEST 8
TEMPERATURE RECORDER-CONTROLLER THERMOMETERS - THERMOMETRIC RESPONSE
Reference: Rule 420-3-16-.10(18) and Rule 420-3-16-.10(21-22)
Application: To all HTST continuous-flow pasteurization systems, except for those in which the FDD is located downstream of the pasteurized regenerator section(s) and/or the final cooler section.
Frequency: Upon installation; at least once each three (3) months thereafter; whenever the temperature recorder-controller thermometer has been repaired and/or replaced; or whenever the regulatory seal has been broken.
Criteria: Five (5) seconds or less.
Apparatus:
-
Accurate time measuring device.
-
The indicating thermometer, which was previously tested against a known accurate test thermometer.
-
Water, oil or other suitable media bath and agitator.
-
Suitable means of heating the media bath.
Method: Measure the time interval between the instant when the temperature recorder-controller thermometer reads 7°C (12°F) below the cut-in temperature and the moment of cut-in by the temperature recorder-controller. This time interval measurement is made when the temperature recorder-controller sensing element is immersed in a rapidly agitated media bath maintained at 4°C (7°F) above the cut-in temperature.
Procedure:
-
Check and, if necessary, adjust the pen-arm setting of the temperature recorder-controller thermometer to read the same as the indicating thermometer at pasteurization temperature.
-
Allow the temperature recorder-controller sensing element to cool to room temperature.
-
Heat the media bath to 4°C (7°F) above the cut-in temperature while continuously agitating the media bath to ensure a uniform temperature.
-
Immerse the temperature recorder-controller sensing element in the media bath. Continue agitation during Procedures 5 and 6 below.
-
Start the accurate time measuring device when the temperature recorder-controller thermometer reaches a temperature of 7°C (12°F) below the cut-in temperature.
-
Stop the accurate time measuring device when the temperature recorder-controller cuts in.
-
Record the results of the test on the appropriate form.
-
Repeat Procedures 1 through 7 for each temperature cut-in set point.
Action: If the response time exceeds five (5) seconds, the temperature recorder-controller shall be repaired or replaced by milk plant personnel. If the temperature recorder-controller fails this test, the pasteurization system shall not be allowed to operate until the cause of this failure has been corrected and compliance has been verified by the Health Officer; or in the case of HACCP listed milk plants, qualified industry personnel acceptable to the Health Officer in compliance with Rule 420-3-16-.10(21-22); or on an emergency basis, an industry temporary testing and sealing program authorized by the Health Officer in compliance with Rule 420-3-16-.10(21-22).
TEST 9
REGENERATOR PRESSURE CONTROLS
Reference: Rule 420-3-16-.10(19) and Rule 420-3-16-.10(21-22)
9.1 PRESSURE SWITCHES
Application: To all pressure switches controlling the operation of a booster pump on HTST pasteurization systems with a regenerator section(s).
Frequency: Upon installation; at least once each three (3) months thereafter; whenever there is any change to the booster pump or the pressure switch circuit; or whenever the regulatory seal has been broken.
Criteria: The booster pump shall not operate unless there is at least a 6.9 kPa (1 psi) pressure differential on the pasteurized milk and/or milk product side of the regenerator section.
Apparatus:
-
A sanitary pressure gauge.
-
Pneumatic testing device, for checking and adjusting the pressure switch settings.
Note: A simple pneumatic testing device may be made from a sanitary tee with a cap on one outlet of the tee that is drilled and tapped and fitted in sequence from the cap with an air bleeder valve, an air pressure reducing valve (suggested range 0-60 psi), and a quick disconnect fitting for attaching a pneumatic device to a milk plant airline.
- A test light of proper voltage placed in-series with the pressure switch contact and in parallel with the booster pump starter.
Method: Check and make the adjustment of the pressure switch to prevent the operation of the booster pump, unless the pressure of the pasteurized milk and/or milk product side of the regenerator section is greater by at least 6.9 kPa (1 psi) than any pressure that may be generated by the booster pump.
Procedure:
- Determine the maximum pressure of the booster pump.
a. Install the sanitary pressure gauge in a tee at the discharge of the booster pump.
b. Operate the pasteurization system on water with the FDD in forward-flow, the timing pump operating at the minimum speed possible, and the booster pump operating at its maximum speed. If a separator and/or vacuum equipment is located between the raw outlet of the regenerator section and the timing pump, the separator and/or vacuum equipment shall be effectively valved-out of the pasteurization system.
c. Determine the maximum pressure indicated by the pressure gauge under these conditions.
- Check and set the pressure switch.
a. Disconnect the pressure switch to be tested from the pasteurization system and connect it to one (1) of the outlets of the pneumatic testing device sanitary tee.
b. Connect the sanitary pressure gauge to the third outlet of the sanitary tee.
c. Close the air pressure regulating valve and fully open the air bleeder valve. Slowly manipulate these valves to bring the air pressure in the pneumatic testing device within the desired range.
Note: By careful manipulation of the air pressure reducing valve and the air bleeder valve, the air pressure in the pneumatic testing device may be regulated slowly and precisely. When operating the pneumatic testing device, care shall be taken to avoid exposing the pressure switch and the sanitary pressure gauge to excessive pressure that might cause damage to the pressure switch.
d. Remove the regulatory seal and cover to expose the adjustment mechanism on the pressure switch.
e. Operate the pneumatic testing device and determine the pressure gauge reading at the booster pump start point on the pressure switch, which will light the test light. If the pressure switch is short circuited, the test light will be lit before the air pressure is applied.
f. The booster pump start point shall be adjusted, if necessary, so as to occur at a pressure gauge reading at least 6.9 kPa (1 psi) greater than the maximum booster pump operating pressure, as determined under Step 1 of this Procedure. If an adjustment is necessary, refer to the manufacturer's instructions for the adjusting procedures. After adjustment, recheck the booster pump start point.
g. Replace the cover, seal the pressure switch, and put the pressure switch sensing element back at its original location.
-
Identify the motor, casing, and impeller of the booster pump.
-
Record the maximum booster pump pressure, the pressure switch setting and the identity of the motor casing and impeller of the booster pump on the appropriate form.
Action: If the pressure switch fails this test, the pasteurization system shall not be allowed to operate until the cause of this failure has been corrected and compliance has been verified by the Health Officer; or in the case of HACCP listed milk plants, qualified industry personnel acceptable to the Health Officer in compliance with Rule 420-3-16-.10(21-22); or on an emergency basis, an industry temporary testing and sealing program authorized by the Health Officer in compliance with Rule 420-3-16-.10(21-22).
9.2 DIFFERENTIAL PRESSURE CONTROLLER
Application: Test 9.2.1 applies to all differential pressure controllers used to control the operation of booster pumps within HTST pasteurization systems or used to control the operation of FDDs on HHST and HTST pasteurization systems with the FDD located downstream of the pasteurized regenerator section(s) and/or the final cooler section.
Test 9.2.2 applies only to HTST pasteurization systems with the FDD located immediately following the holding tube.
Test 9.2.3 applies to the testing of continuous-flow pasteurization systems in which the differential pressure controller is used to control the operation of the FDD.
Frequency: Upon installation; at least once each three (3) months thereafter; whenever the differential pressure controller is adjusted or repaired; or whenever the regulatory seal has been broken.
Criteria: The booster pump shall not operate, or the pasteurization system shall not operate in forward-flow, unless the milk and/or milk product pressure in the pasteurized side of the regenerator section(s) is at least 6.9 kPa (1 psi) greater than the milk and/or milk product pressure in the raw side of the regenerator section(s). When the differential pressure controller is used to control the FDD on HHST pasteurization systems, and improper pressure occurs in the regenerator section(s), the FDD shall move to the diverted-flow position and remain in diverted-flow until the proper pressures are re-established in the regenerator section(s) and all milk and/or milk product-contact surfaces between the holding tube and the FDD have been held at or above the minimum legal pasteurization temperature continuously and simultaneously for at least the required time.
Apparatus:
-
A sanitary pressure gauge.
-
Pneumatic testing device described in Test 9.1 PRESSURE SWITCHES can be used for checking and adjusting the differential pressure switch setting.
-
Water, oil or other suitable media bath and agitator.
-
Suitable means of heating the media bath (refer to Test 9.2.2).
-
Test light (refer to Test 9.2.3).
Method: The differential pressure switch is checked and adjusted to prevent the operation of the booster pump, or prevent forward-flow, unless the milk and/or milk product pressure in the pasteurized side of the regenerator section(s) is at least 6.9 kPa (1 psi) greater than the pressure in the raw side of the regenerator section(s).
9.2.1 CALIBRATION OF THE DIFFERENTIAL PRESSURE CONTROLLER SENSING ELEMENTS
Procedure:
-
Loosen the sanitary pipeline connections to both differential pressure controller pressure sensing elements and wait for any liquid to drain through the loose sanitary pipeline connections. Both pointers or digital displays shall be within 3.5 kPa (0.5 psi) of 0 kPa (0 psi). If not, adjust the pointer(s) or the digital display(s) to read 0 kPa (0 psi).
-
Remove both differential pressure controller sensing elements from the pasteurization system and mount them on a testing tee which is connected either at the discharge of the booster pump or at the pneumatic testing device. Note the separation between the two (2) pointers or digital displays. A change in elevation of the differential pressure controller sensing elements may cause some change in the 0 kPa (0 psi) readings. Turn on the booster pump switch and activate the test switch/button to operate the booster pump, or if the pneumatic testing device is used in lieu of the booster pump, adjust the air pressure to the normal operating pressure of the booster pump. Note that the pointers or digital display reading separation is within 6.9 kPa (1 psi) of that observed before the pressure was applied.
-
Record the results of the test on the appropriate form.
Action: If the differential pressure controller fails to respond as indicated above, an immediate check of the differential pressure controller is required by milk plant personnel to correct the cause of the failure. If after adjustment and/or repair the differential pressure controller fails this test, the pasteurization system shall not be allowed to operate until the cause of this failure has been corrected and compliance has been verified by the Health Officer; or in the case of HACCP listed milk plants, qualified industry personnel acceptable to the Health Officer in compliance with Rules 420-3-16-.10(21-22); or on an emergency basis, an industry temporary testing and sealing program authorized by the Health Officer in compliance with Rules 420-3-16-.10(21-22).
9.2.2 HTST - INTERWIRING OF THE DIFFERENTIAL PRESSURE CONTROLLER WITH THE BOOSTER PUMP
Method: Determine if the booster pump stops running when the pressure differential is not properly maintained in the regenerator section(s).
Procedure:
- Connect the pasteurized regenerator section differential pressure controller sensing element to a testing tee with the other end of the testing tee capped.
Note: If there is water in the HTST pasteurization system, ensure that the recorder-controller sensing element and the pasteurized regenerator section differential pressure controller sensing element ports are capped before the timing pump is turned on.
-
Turn on the timing pump and the booster pump.
-
Place the recorder-controller sensing element in a hot media bath which is above the cut-in temperature.
-
Increase the air supply on the testing tee to provide an adequate pressure differential to start the booster pump. The booster pump shall start running.
-
Decrease the air supply to the testing tee until the pasteurized milk and/or milk product differential pressure controller sensing element pressure is less than 14 kPa (2 psi) greater than the pressure on the raw milk and/or milk product side differential pressure controller sensing element. The booster pump shall stop running. Ensure that the FDD remains in the forward-flow position and the timing pump continues to operate.
-
Record the results of the test on the appropriate form.
Action: If the booster pump fails to stop running when the pressure differential is not maintained, milk plant personnel shall determine and correct the problem. If after adjustment and/or repair the differential pressure controller fails this test, the pasteurization system shall not be allowed to operate until the cause of this failure has been corrected and compliance has been verified by the Health Officer; or in the case of HACCP listed milk plants, qualified industry personnel acceptable to the Health Officer in compliance with Rule 420-3-16-.10(21-22); or on an emergency basis, an industry temporary testing and sealing program authorized by the Health Officer in compliance with Rule 420-3-16-.10(21-22).
9.2.3 INTERWIRING OF THE DIFFERENTIAL PRESSURE CONTROLLER WITH THE FDD IN AN HHST CONTINUOUS-FLOW PASTEURIZATION SYSTEM
Application: To all differential pressure controllers used to control the operation of FDDs on HHST continuous-flow pasteurization systems with the FDD located downstream of the pasteurized regenerator section(s) and/or final cooler section.
Method: The differential pressure controller is checked and adjusted to prevent forward-flow unless the milk and/or milk product pressure in the pasteurized side of the regenerator section(s) is at least 6.9 kPa (1 psi) greater than the pressure in the raw milk and/or milk product side of the regenerator section(s). In the case of milk and/or milk product-to-water-to-milk or milk product regenerators protected on the pasteurized side of the regenerator section(s), the “water side” of the regenerator section(s) shall be considered to be the "raw product side" for purposes of this test.
Procedure:
-
Wire the test light in series with the signal from the differential pressure controller to the FDD.
-
Calibrate the differential pressure controller and sensing elements. (Use Test 9.2.1.)
-
Adjust the pressure on the differential pressure controller sensing elements to their normal operating pressures, with the pasteurized milk and/or milk product pressure at least 14 kPa (2 psi) higher than the raw milk and/or milk product pressure.
a. The test light shall be lit. If not, increase the pasteurized milk and/or milk product pressure or lower the raw milk and/or milk product pressure until the test light is lit.
b. Gradually lower the pasteurized milk and/or milk product pressure or raise the raw milk and/or milk product pressure until the test light turns off.
c. The test light shall turn off when the pasteurized milk and/or milk product pressure is at least 14 kPa (2 psi) higher than the raw milk and/or milk product pressure.
d. Note the pressure differential at the point the test light turns off.
e. Gradually raise the pasteurized milk and/or milk product pressure or lower the raw milk and/or milk product pressure until the test light turns on.
f. The test light shall not turn on until the pasteurized milk and/or milk product pressure is at least 14 kPa (2 psi) higher than the raw milk and/or milk product pressure. Note the pressure differential at the point the test light turns off.
Note: This test may be completed using a pneumatic testing device capable of producing pressure differentials on the sensing elements duplicating the conditions described above.
- Record the results of the test on the appropriate forms.
Action: If the differential pressure controller fails to respond as indicated above, an immediate check of the differential pressure controller is required by milk plant personnel to locate and correct the problem. If after adjustment and/or repair the differential pressure controller fails this test, the pasteurization system shall not be allowed to operate until the cause of this failure has been corrected and compliance has been verified by the Health Officer; or in the case of HACCP listed milk plants, qualified industry personnel acceptable to the Health Officer in compliance with Rule 420-3-16-.10(21-22); or on an emergency basis, an industry temporary testing and sealing program authorized by the Health Officer in compliance with Rule 420-3-16-.10(21-22).
9.3 ADDITIONAL HTST PASTEURIZATION SYSTEM TESTS FOR BOOSTER PUMPS – INTERWIRING
Application: To all booster pumps used for HTST pasteurization systems where the FDD is located immediately downstream of the holding tube, except that Test 9.3.2 is not required to be performed on magnetic flow meter based timing systems.
Frequency: Upon installation; at least once each three (3) months thereafter; whenever there is any change to the booster pump or the booster pump interwiring; or when the regulatory seal has been broken.
Criteria: The booster pump shall be wired so it cannot operate if the FDD is in the diverted-flow position or if the timing pump is not in operation.
Apparatus:
-
A sanitary pressure gauge.
-
Pneumatic testing device, described in Test 9.1 Pressure Switches, can be used for checking and adjusting the differential pressure controller setting (refer to Test 9.1).
-
Water, oil or other suitable media bath and agitator.
-
Suitable means of heating the media bath.
9.3.1 BOOSTER PUMPS-INTERWIRED WITH FDD
Method: Determine if the booster pump stops running by dropping the temperature and causing the FDD to divert.
Procedure:
- Connect the pasteurized regenerator section(s) differential pressure controller sensing element to a testing tee with the other end of the testing tee capped.
Note: If there is water in the HTST pasteurization system, ensure that the recorder-controller sensing element and the pasteurized regenerator section(s) differential pressure controller sensing element ports are capped before the timing pump is turned on.
-
Turn on the timing pump and the booster pump.
-
Place the recorder-controller sensing element in a hot media bath which is above the cut-in temperature.
-
Increase the air supply on the testing tee to provide an adequate pressure differential to start the booster pump. The booster pump shall start running.
-
Remove the recorder-controller sensing element from the hot media bath.
-
When the FDD moves to the diverted-flow position, the booster pump shall stop running. Ensure that the pressure differential remains greater than or equal to 6.9 kPa (1 psi) and the other flow-promoting devices which are capable of causing flow through the FDD in the timing system continue to operate.
-
Record the results of the test on the appropriate form.
Action: If the booster pump fails to stop running when the FDD is in the diverted-flow position, milk plant personnel shall determine and correct the cause. If after adjustment and/or repair the booster pump fails this test, the pasteurization system shall not be allowed to operate until the cause of this failure has been corrected and compliance has been verified by the Health Officer; or in the case of HACCP listed milk plants, qualified industry personnel acceptable to the Health Officer in compliance with Rule 420-3-16-.10(21-22) or on an emergency basis, an industry temporary testing and sealing program authorized by the Health Officer in compliance with Rule 420-3-16-.10(21-22).
9.3.2 BOOSTER PUMPS - INTERWIRED WITH THE TIMING PUMP
Method: Determine if the booster pump stops running when the timing pump is not running.
Procedure:
- Connect the pasteurized regenerator section(s) differential pressure controller sensing element to a testing tee with the other end of the testing tee capped.
Note: If there is water in the HTST pasteurization system, ensure that the recorder-controller sensing element and the pasteurized regenerator section(s) differential pressure controller sensing element ports are capped before the timing pump is turned on.
-
Turn on the timing pump and the booster pump.
-
Place the recorder-controller sensing element in a hot media bath which is above the cut-in temperature.
-
Increase the air supply on the testing tee to provide an adequate pressure differential to start the booster pump. The booster pump shall start running.
-
Turn off the timing pump. The booster pump shall stop running. Ensure that the pressure differential remains adequate and the FDD remains in the forward-flow position.
-
Record the results of the test on the appropriate form.
Action: If the booster pump fails to stop running when the timing pump is not running, milk plant personnel shall determine and correct the cause. If after adjustment and/or repair the booster pump fails this test, the pasteurization system shall not be allowed to operate until the cause of this failure has been corrected and compliance has been verified by the Health Officer; or in the case of HACCP listed milk plants, qualified industry personnel acceptable to the Health Officer in compliance with Rule 420-3-16-.10(21-22); or on an emergency basis, an industry temporary testing and sealing program authorized by the Health Officer in compliance with Rule 420-3-16-.10(21-22).
TEST 10
MILK OR MILK PRODUCT-FLOW CONTROLS AND THE MILK OR MILK PRODUCT TEMPERATURE AT CUT-IN AND CUT-OUT
References: Rule 420-3-16-.10(18) and Rule 420-3-16-.10(21-22)
Frequency: Milk and/or milk product flow controls shall be tested for the milk and/or milk product temperature at cut-in and cut-out by one (1) of the following applicable tests at the frequency prescribed.
Apparatus:
-
Water, oil or other suitable media bath and agitator.
-
Suitable means of heating the media bath.
-
Test light for Tests 10.2 and 10.3.
10.1 HTST PASTEURIZATION SYSTEMS
Application: To all recorder-controllers used in connection with HTST pasteurization systems, except those in which the FDD is located downstream from the pasteurized regenerator section(s) and/or final cooler section.
Frequency: Upon installation; at least once each three (3) months thereafter; whenever the recorder-controller and/or recorder-controller thermometer has been repaired and/or replaced; or whenever the regulatory seal has been broken; and daily by a milk plant’s pasteurization system operator.
Criteria: Forward-flow cannot be achieved until at least the minimum legal pasteurization temperature has been reached. Flow shall be diverted before the temperature drops below the minimum legal pasteurization temperature.
Method: By observing the actual temperature of the indicating thermometer at the instant forward-flow starts (cut-in) and forward-flow stops (cut-out).
Procedure:
- Cut-in Temperature:
a. While milk, milk product, or water is completely flooding the sensing elements of the recorder-controller and the indicating thermometer, which was previously tested against a known accurate test thermometer, increase the heat gradually so as to raise the temperature of the milk, milk product, or water at a rate not to exceed 0.5°C (1°F) per thirty (30) seconds. If a water, oil, or other suitable media bath is used in place of milk, milk product, or water flowing through the pasteurization system, the water, oil, or other suitable media bath shall be adequately and continuously agitated during this test.
b. Observe the indicating thermometer reading at the moment forward-flow begins, i.e., the FDD moves. Observe that the recorder-controller event pen reading is synchronized with the recording pen on the same reference arc as on the recording chart.
c. Immediately record and identify on the recording chart the observed indicating thermometer temperature reading at cut-in and initial the recording chart. This may be accomplished by inscribing a line intersecting the recorded temperature arc at the pen location or any other method acceptable to the Health Officer.
- Cut-out Temperature:
a. After the cut-in temperature has been determined, and while the milk, milk product, or water is above the cut-in temperature, allow the milk, milk product, or water to cool slowly at a rate not to exceed 0.5°C (1°F) per thirty (30) seconds. If a water, oil, or other suitable media bath is used in place of milk, milk product, or water flowing through the pasteurization system, the water, oil, or other suitable media bath shall be adequately and continuously agitated during this test.
b. Observe the indicating thermometer reading at the moment flow is diverted. Observe that the recorder-controller event pen reading is synchronized with the recording pen on the same reference arc as on the recording chart.
c. Immediately record and identify on the recording chart the observed indicating thermometer temperature reading at cut-out and initial the recording chart. This may be accomplished by inscribing a line intersecting the recorded temperature arc at the pen location or any other method acceptable to the Health Officer.
- Record the results of both the cut-in and cut-out tests on the appropriate form.
Action: If the cut-in and/or cut-out indicating thermometer reading is below the minimum legal pasteurization temperature, the cut-in and/or cut-out setting(s) shall be adjusted by milk plant personnel. If after adjustment the cut-in and/or cut-out temperature(s) fail this test, the pasteurization system shall not be allowed to operate until the cause of this failure has been corrected and compliance has been verified by the Health Officer; or in the case of HACCP listed milk plants, qualified industry personnel acceptable to the Health Officer in compliance with Rule 420-3-16-.10(21-22); or on an emergency basis, an industry temporary testing and sealing program authorized by the Health Officer in compliance with Rule 420-3-16-.10(21-22).
10.2 PASTEURIZATION SYSTEMS USING INDIRECT HEATING
Application: To all HHST and HTST continuous-flow pasteurization systems with the FDD located downstream of the pasteurized regenerator section(s) and/or the final cooler section using indirect heating.
Frequency: Upon installation; at least once each three (3) months thereafter; whenever the recorder-controller and/or recorder-controller thermometer has been repaired and/or replaced; or whenever the recorder-controller thermometer regulatory seal has been broken.
Criteria: The pasteurization system shall not operate in forward-flow unless the minimum legal pasteurization temperature has been achieved in the holding tube and at the FDD. The milk and/or milk product flow shall be diverted before the temperature falls below the minimum legal pasteurization temperature in the holding tube.
Method: The cut-in and cut-out temperatures as read from the indicating thermometer located within the pasteurization system are determined using a media bath and the sensing elements from the holding tube and the FDD.
Procedure:
- Cut-in Temperature:
a. Wire the test light in series with the control contacts of the holding tube recorder-controller sensing element. Immerse the recorder-controller and holding tube indicating sensing elements in the media bath. Raise the media bath temperature at a rate not to exceed 0.5°C (1°F) per thirty (30) seconds. Observe the temperature reading on the indicating thermometer when the test light comes on, which is the cut-in temperature.
b. Record the observed indicating thermometer cut-in reading on the appropriate form.
- Cut-out Temperature:
a. After the cut-in temperature has been determined and while the media bath is above the cut-in temperature, allow the media bath to cool slowly at a rate not to exceed 0.5°C (1°F) per thirty (30) seconds. Observe the temperature reading on the recorder-controller when the test light goes out, which is the cut-out temperature. Determine that the cut-out temperature on the recorder-controller is equivalent to or greater than the minimum legal pasteurization temperature.
b. Record the observed indicating thermometer cut-out reading on the appropriate form.
- Repeat the procedure for the FDD sensing element. Rewire the test light in series with the control contacts for the FDD sensing element.
Action: Whenever adjustment is necessary, refer to the manufacturer’s instructions. Retest the cut-in and cut-out temperatures after any adjustment, repair, replacement, or whenever the regulatory seal has been broken. If after adjustment the cut-in and/or cut-out temperature(s) fail this test, the pasteurization system shall not be allowed to operate until the cause of this failure has been corrected and compliance has been verified by the Health Officer; or in the case of HACCP listed milk plants, qualified industry personnel acceptable to the Health Officer in compliance with Rule 420-3-16-.10(21-22); or on an emergency basis, an industry temporary testing and sealing program authorized by the Health Officer in compliance with Rule 420-3-16-.10(21-22).
10.3 PASTEURIZATION SYSTEMS USING DIRECT HEATING
Application: To all HHST and HTST continuous-flow pasteurization systems with the FDD located downstream of the pasteurized regenerator section(s) and/or the final cooler section using direct heating.
Frequency: Upon installation; at least once each three (3) months thereafter; whenever the recorder-controller and/or recorder-controller thermometer has been repaired and/or replaced; or whenever the recorder-controller thermometer regulatory seal has been broken.
Criteria: The pasteurization system shall not operate in forward-flow unless the minimum legal pasteurization temperature has been achieved in the holding tube, at the vacuum chamber, and at the FDD. The milk and/or milk product flow shall be diverted before the temperature falls below the minimum legal pasteurization temperature in the holding tube.
Method: The cut-in and cut-out temperatures as read from the indicating thermometer located within the pasteurization system are determined using a media bath and the sensing elements from the holding tube, vacuum chamber and the FDD.
Procedure:
- Cut-in Temperature:
a. Wire the test light in series with the control contacts of the holding tube recorder-controller sensing element. Immerse the recorder-controller and holding tube indicating sensing elements in the media bath. Raise the media bath temperature at a rate not to exceed 0.5°C (1°F) per thirty (30) seconds. Observe the temperature reading on the indicating thermometer when the test light comes on, which is the cut-in temperature.
b. Record the observed indicating thermometer cut-in reading on the appropriate form.
- Cut-out Temperature:
a. After the cut-in temperature has been determined and while the media bath is above the cut-in temperature, allow the media bath to cool slowly at a rate not to exceed 0.5°C (1°F) per thirty (30) seconds. Observe the temperature reading on the recorder-controller when the test light goes out, which is the cut-out temperature. Determine that the cut-out temperature on the recorder-controller is equivalent to or greater than the minimum legal pasteurization temperature.
b. Record the observed indicating thermometer cut-out reading on the appropriate form.
- Repeat the procedure for the other two (2) sensing elements, from the vacuum chamber, and the FDD. Rewire the test light in series with the control contacts for each sensing element, respectively.
Action: Whenever adjustment is necessary, refer to the manufacturer’s instructions. Retest the cut-in and cut-out temperatures after any adjustment, repair, replacement, or whenever the regulatory seal has been broken. If after adjustment the cut-in and/or cut-out temperature(s) fail this test, the pasteurization system shall not be allowed to operate until the cause of this failure has been corrected and compliance has been verified by the Health Officer; or in the case of HACCP listed milk plants, qualified industry personnel acceptable to the Health Officer in compliance with Rule 420-3-16-.10(21-22); or on an emergency basis, an industry temporary testing and sealing program authorized by the Health Officer in compliance with Rule 420-3-16-.10(21-22),
TEST 11
CONTINUOUS-FLOW PASTEURIZATION SYSTEM HOLDING TUBES – PASTEURIZATION HOLDING TIME
(Continuous-flow pasteurization system holding tubes shall be tested for pasteurization holding times by one [1] of the following applicable tests.)
Reference: Rule 420-3-16-.10(18) and Rule 420-3-16-.10(21-22)
11.1 HTST PASTEURIZATION SYSTEMS
(Except for magnetic flow meter based timing systems.)
Application: To all HTST continuous-flow pasteurization systems employing a pasteurization holding time of fifteen (15) seconds or longer, except for magnetic flow meter based timing systems.
Frequency: Upon installation; at least once each six (6) months thereafter; whenever any alteration is made affecting the pasteurization holding time, the velocity of the flow, such as the replacement of the timing pump, motor, belt, drive or driven pulleys, or a decrease in the number of HTST pasteurization system heat-exchange plates or the capacity of the holding tube; whenever a check of the capacity of the holding tube indicates a speedup; or whenever the regulatory seal on the timing pump speed setting has been broken.
Criteria: Every particle of milk and/or milk product shall be held for at least a minimum legal pasteurization holding time of fifteen (15) seconds or twenty-five (25) seconds, respectively in both forward-flow and diverted-flow.
Apparatus:
-
An electrical conductivity measuring device, which is capable of detecting a change in conductivity and is equipped with standard electrodes.
-
Table salt (sodium chloride) or other appropriate conductive solution.
-
A suitable apparatus for injecting the salt solution or other appropriate conductive solution into the holding tube.
-
An accurate time measuring device.
Method: The pasteurization holding time is determined by timing the interval for an injected trace substance such as sodium chloride to pass through the entire length of the legal holding tube. Although the time interval of the fastest particle of milk and/or milk product is desired, this conductivity test is performed using water. The results obtained when using water are converted to the milk and/or milk product flow pasteurization holding time, using either the volume or weight formulation, as shown below, since a timing pump may not deliver the same amount of milk and/or milk product as it does water.
Procedure:
- Operate the pasteurization system on water, with all flow-promoting devices which are capable of causing flow through the FDD, operating at their maximum capacity and all flow-impeding devices adjusted or bypassed to provide the minimum amount of resistance to the flow through the pasteurization system. There shall not be any leakage on the suction side of the timing pump.
Note: In pasteurization systems equipped with a pressure relief valve located between the timing pump and the beginning of the holding tube, this test shall not be performed if the pressure relief valve is observed to be leaking.
a. For a variable speed timing pump adjust the timing pump to its maximum capacity, preferably with a new belt and full size impellers.
b. For a homogenizer used as the timing pump, check the homogenizer for its regulatory seal(s) and gears or pulley identification.
c. For alternating current (AC) variable speed timing pump, check the timing pump’s control box for its regulatory seal(s).
Note: For pasteurization systems that employ a liquid ingredient injection (slurry) system as described in Appendix H, the slurry injection pump shall be energized and running at its maximum speed and the slurry supply tank shall be completely filled with water.
-
If utilizing an electrical conductivity measuring device that is equipped with two (2) standard electrodes, install one (1) electrode at the beginning of the legal holding tube and the other electrode at the end of the legal holding tube. If utilizing an electrical conductivity measuring device that is equipped with a single standard electrode, install the electrode at the end of the legal holding tube.
-
Operate the pasteurization system using water at or above the minimum legal pasteurization temperature with the FDD in the forward-flow position.
-
Quickly inject a saturated sodium chloride or other appropriate conductive solution into the inlet at the beginning of the legal holding tube.
-
The accurate time measuring device shall start at the moment when the conductivity solution is injected. This may be accomplished by detecting a change in conductivity at the beginning of the holding tube when utilizing two (2) electrodes or by a switch placed at the beginning of the holding tube synchronized with the injection process when utilizing a single electrode placed at the end of the holding tube.
-
The accurate time measuring device shall stop when it detects a change in conductivity at the end of the legal holding tube.
-
Repeat this test six (6) or more times, until six (6) consecutive results are within 0.5 seconds of each other. The average of these six (6) consecutive tests is the pasteurization holding time for water in forward-flow.
Note: When consistent test readings cannot be obtained, purge the pasteurization system, check the testing instruments and connections, and check for any air leakage on the suction side of the timing pump. Repeat Procedure 7. When consistent readings cannot be obtained after repeating Procedure 7, use the fastest time obtained from any of these tests as the pasteurization holding time for water in forward-flow.
-
Record all of the pasteurization holding time results for water in forward-flow as conducted in Procedure 7 above and the average of these six (6) consecutive tests on the appropriate form.
-
Repeat Procedures 3 through 7 above for the pasteurization holding time for water in diverted-flow.
-
Record all of the pasteurization holding time results for water in diverted-flow as conducted in Procedure 9 above on the appropriate form.
-
Complete a, b, or c below as appropriate:
a. For all gear driven timing pumps, complete Procedures 12 through 16 below.
b. For those homogenizers used as timing pumps, when the measured pasteurization holding time for water is less than 120 percent of the minimum legal pasteurization holding time, complete Procedures 12 through 16 below.
c. For those homogenizers used as timing pumps, when the measured pasteurization holding time for water is 120 percent or more of the minimum legal pasteurization holding time, Procedure 12 is optional and Procedure 13 through 16 below are not required.
- With the timing pump at the same speed and all other flow-promoting devices which are capable of causing flow through the FDD and flow-impeding devices adjusted as cited in Procedure 1, determine the time it takes to fill a 38 liter (10 gallon) can with a measured weight or volume of water, using the pasteurization system discharge outlet with the same head pressure as is normally used during the operation of the pasteurization system. Average the filling times for several trials (minimum of three [3]).
Note: Since flow rates of a large capacity unit make it very difficult to determine the time it takes to fill a 38 liter (10 gallon) can with a measured weight or volume of water, it is recommended that a calibrated tank of considerable size be used. It is also acceptable to use any other means to determine a measured weight or volume of water.
-
Record all of the can fill time results and the average time it takes to fill a 38 liter (10 gallon) can or other means as described in the Note: above with a measured weight or volume of water for Procedure 12 above on the appropriate form.
-
Repeat Procedure 12 above using milk.
-
Record the average time it takes to fill a 38 liter (10 gallon) can or other means used with a measured weight or volume of milk for Procedure 14 above on the appropriate form.
-
Compute the pasteurization holding time for milk from one (1) of the following formulas either by volume or by weight. Compute separately for forward-flow and diverted-flow.
BY VOLUME
The adjusted pasteurization holding time for milk is equal to:
The pasteurization holding time for water, times the quotient of the time it takes to deliver a volume of milk, divided by the time it takes to deliver the same volume of water.
Tm = Tw(Vm/Vw)
Where: Tm = Adjusted product pasteurization holding time for milk.
Tw = Pasteurization holding time for water, the salt (sodium chloride or other appropriate conductive solution) test results.
Vm = Time, usually in seconds, that it takes to pump a known volume of milk.
Vw = Time, usually in seconds, that it takes to pump the same volume of water.
BY WEIGHT (Using specific gravity):
The adjusted pasteurization holding time for milk is equal to:
The specific gravity of milk, times the pasteurization holding time for water, times the quotient of the time it takes to deliver a measured weight of milk, divided by the time it takes to deliver the same weight of water.
Tm = 1.032xTw(Wm/Ww)
Where: Tm = Adjusted product pasteurization holding time for milk.
1.032 = The specific gravity of milk
Note: If another milk product is used, use the appropriate specific gravity.
Tw = Pasteurization holding time for water, the salt (sodium chloride or other appropriate conductive solution) test results.
Wm = Time, usually in seconds, that it takes to pump a measured weight of milk.
Ww = Time, usually in seconds, that it takes to pump the same measured weight of water.
- Record the computed adjusted pasteurization holding time for forward-flow and divert-flow for milk using either the formula for volume or weight as identified in Procedure 16 above on the appropriate form.
Action: When the computed adjusted pasteurization holding time for milk is less than the minimum legal pasteurization holding time, either in forward-flow or diverted-flow, the speed of the timing pump shall be reduced or an adjustment shall be made to the length or diameter of the holding tube and Test 11.1 shall be repeated until a satisfactory pasteurization holding time is achieved. If an orifice (restrictor) is required to be installed in the FDD divert line to comply with the minimum legal pasteurization holding time in diverted-flow, there shall not be any excessive pressure exerted on the underside of the valve seat of the FDD. Variable speed drives shall be sealed for motors on timing pumps that do not provide a constant speed as provided for in Rule 420-3-16-.10(18)(J)2. If after adjustment the pasteurization holding time fails this test, the pasteurization system shall not be allowed to operate until the cause of this failure has been corrected and compliance has been verified by the Health Officer; or in the case of HACCP listed milk plants, qualified industry personnel acceptable to the Health Officer in compliance with Rule 420-3-16-.10(21-22); or on an emergency basis, an industry temporary testing and sealing program authorized by the Health Officer in compliance with Rule 420-3-16-.10(21-22).
11.2A CONTINUOUS-FLOW PASTEURIZATION SYSTEMS UTILIZING A MAGNETIC FLOW METER BASED TIMING SYSTEM – PASTEURIZATION HOLDING TIME
Application: To all HTST continuous-flow pasteurization systems with a magnetic flow meter based timing system used in lieu of a timing pump.
Frequency: Upon installation; at least once each six (6) months thereafter; whenever any alteration is made affecting the pasteurization holding time, the velocity of the flow or the capacity of holding tube; or whenever a check of the capacity indicates a speed up; or whenever the regulatory seal on the flow alarm has been broken.
Criteria: Every particle of milk and/or milk product shall be held for at least a minimum legal pasteurization holding time of fifteen (15) seconds or twenty-five (25) seconds, respectively in both forward-flow and diverted-flow.
Apparatus:
-
An electrical conductivity measuring device which is capable of detecting a change in conductivity and is equipped with standard electrodes.
-
Table salt (sodium chloride) or other appropriate conductive solution.
-
A suitable apparatus for injecting the salt solution or other appropriate conductive solution into the holding tube.
-
An accurate time measuring device.
-
Water, oil or other suitable media bath and agitator.
-
Suitable means of heating the media bath.
Method: The pasteurization holding time is determined by timing the interval for an injected trace substance, such as sodium chloride, to pass through the entire length of the legal holding tube.
Procedure:
Utilize either TEST OPTION I or TEST OPTION II.
Note: In pasteurization systems equipped with a pressure relief valve located between the timing pump and the beginning of the holding tube, this test shall not be performed if the pressure relief valve is observed to be leaking.
TEST OPTION I:
-
Adjust the set point on the high flow alarm above the estimated acceptable flow rate or bypass the high flow alarm.
-
Adjust the set point on the flow recorder-controller to a flow rate estimated to yield an acceptable pasteurization holding time.
-
Install one (1) electrode at the beginning of the legal holding tube and the other electrode at the end of the legal holding tube.
-
Operate the pasteurization system using water at or above the minimum legal pasteurization temperature, with the FDD in the forward-flow position.
Note: The appropriate temperature sensing elements may be placed in a water, oil, or other suitable media bath to simulate the minimum legal pasteurization temperature in the holding tube as an alternative method to the heating of water in the pasteurization system above the minimum legal pasteurization temperature.
-
Quickly inject a saturated sodium chloride or other appropriate conductive solution into the inlet at the beginning of the legal holding tube.
-
The accurate time measuring device shall start when it detects a change in conductivity at the beginning of the legal holding tube.
-
The accurate time measuring device shall stop when it detects a change in conductivity at the end of the legal holding tube.
-
Repeat this test six (6) or more times, until six (6) consecutive results are within 0.5 seconds of each other. The average of these six (6) consecutive tests is the pasteurization holding time for water in forward-flow.
Note: If six (6) consecutive tests cannot be achieved within 0.5 seconds of each other, refer to Action below.
-
Record all of the pasteurization holding time results for water in forward-flow as conducted in Procedure 8 above and the average of these six (6) consecutive tests on the appropriate form.
-
This procedure is not a required test; it is at the option of the Health Officer. With the flow rate recorder-controller at the same set point as in Procedure 2, determine the time it takes to fill a 38 liter (10 gallon) can with a measured weight or volume of water using the pasteurization system discharge outlet with the same head pressure as is normally used during the operation of the pasteurization system. Average the time of several trials (minimum of three [3]). Since flow rates of a large capacity unit make it very difficult to determine the time it takes to fill a 38 liter (10 gallon) can with a measured weight or volume of water, it is suggested that a calibrated tank of considerable size be used. It is also acceptable to use any other means to determine a measured weight or volume of water.
-
If the Health Officer chooses to conduct Procedure 10 above, record all of the can fill time results and the average time it takes to fill a 38 liter (10 gallon) can or other means used with a measured weight or volume of milk for Procedure 10 above on the appropriate form.
TEST OPTION II:
-
If utilizing an electrical conductivity measuring device that is equipped with two (2) standard electrodes, install one (1) electrode at the beginning of the legal holding tube and the other electrode at the end of the legal holding tube. If utilizing an electrical conductivity measuring device that is equipped with a single standard electrode, install the electrode at the end of the legal holding tube.
-
Operate the pasteurization system using water with the FDD in the divert-flow position at a flow rate just above the high flow alarm set point.
-
Quickly inject a saturated sodium chloride or other appropriate conductive solution into the inlet at the beginning of the legal holding tube.
-
The accurate time measuring device shall start at the moment when the conductivity solution is injected. This may be accomplished by detecting a change in conductivity at the beginning of the holding tube when utilizing two (2) electrodes or by a switch placed at the beginning of the holding tube synchronized with the injection process when utilizing a single electrode placed at the end of the holding tube.
-
The accurate time measuring device shall stop when it detects a change in conductivity at the end of the legal holding tube.
-
Repeat this test six (6) or more times, until six (6) consecutive results are within 0.5 seconds of each other. The average of these six (6) consecutive tests is the pasteurization holding time for water in diverted-flow.
Note: If six (6) consecutive tests cannot be achieved within 0.5 seconds of each other, refer to Action below.
-
Record all of the pasteurization holding time results for water in diverted-flow as conducted in Procedure 6 above and the average of these six (6) consecutive tests on the appropriate form.
-
If the minimum legal pasteurization holding time is achieved in diverted-flow when conducting TEST OPTION II, all flows through the pasteurization system below the high flow alarm set point will meet the required minimum legal pasteurization holding time in forward- flow. Proceed to Procedure 10 below.
-
If the test results when conducting TEST OPTION II are not all above the required minimum legal pasteurization holding time in diverted-flow, TEST OPTION I shall be conducted.
-
This procedure is not a required test; it is at the option of the Health Officer. With the flow rate recorder-controller at the same set point as in Procedure 2, determine the time it takes to fill a 38 liter (10 gallon) can with a measured weight or volume of water using the pasteurization system discharge outlet with the same head pressure as is normally used during the operation of the pasteurization system. Average the time of several trials (minimum of three [3]). Since flow rates of a large capacity unit make it very difficult to determine the time it takes to fill a 38 liter (10 gallon) can with a measured weight or volume of water, it is suggested that a calibrated tank of considerable size be used. It is also acceptable to use any other means to determine a measured weight or volume of water.
-
If the Health Officer chooses to conduct Procedure 10 above, record all of the can fill time results and the average time it takes to fill a 38 liter (10 gallon) can or other means used with a measured weight or volume of milk for Procedure 10 above on the appropriate form.
Action: When the computed pasteurization holding time for milk is less than the minimum legal pasteurization holding time in diverted-flow, the set point on the flow rate recorder-controller shall be decreased, or an adjustment shall be made in the length or diameter of the legal holding tube by milk plant personnel to correct the pasteurization holding time, and TEST OPTION I shall be repeated until a satisfactory pasteurization holding time is achieved. If after adjustment the pasteurization system fails this test, the pasteurization system shall not be allowed to operate until the cause of this failure has been corrected and compliance has been verified by the Health Officer; or in the case of HACCP listed milk plants, qualified industry personnel acceptable to the Health Officer in compliance with Rule 420-3-16-.10(21-22); or on an emergency basis, an industry temporary testing and sealing program authorized by the Health Officer in compliance with Rule 420-3-16-.10(21-22).
11.2B CONTINUOUS-FLOW PASTEURIZATION SYSTEMS UTILIZING A MAGNETIC FLOW METER BASED TIMING SYSTEM – HOLDING TUBES AND HIGH FLOW ALARM
Application: To all continuous-flow pasteurization systems using a magnetic flow meter based timing system in lieu of a timing pump.
Frequency: Upon installation; at least once each six (6) months thereafter; whenever any alteration is made affecting the pasteurization holding time, the velocity of the flow, or the capacity of the holding tube; whenever a check of the capacity of the holding tube indicates a speedup; or whenever the regulatory seal on the high flow alarm has been broken.
Criteria: Whenever the high flow rate equals or exceeds the value at which the pasteurization holding time was measured, the high flow alarm shall cause the FDD to assume the diverted-flow position, even though the temperature of the milk and/or milk product in the holding tube is above the minimum legal pasteurization temperature.
Apparatus: No supplementary materials required.
Method: The high flow alarm set point shall be set so that flow is diverted when the flow rate equals or exceeds the value at which the pasteurization holding time was measured or calculated.
Procedure:
- Operate the pasteurization system using water above the minimum legal pasteurization temperature in forward-flow at a flow rate below the high flow alarm set point.
Note: The appropriate temperature sensing elements may be placed in a water, oil, or other suitable media bath to simulate the processing pasteurization temperature within the holding tube as an alternative to heating water in the pasteurization system above the minimum legal pasteurization temperature.
- Slowly raise the flow rate of the pasteurization system until the following occur:
a. The frequency pen(s) on the STLR and the flow rate recorder-controller(s) indicate that the FDD is in the diverted-flow position.
b. Observe that the FDD moved to the diverted-flow position.
- Record the rate of flow; the set point of the high flow alarm; and the temperature on the STLR at the occurrence of flow-diversion for this test on the appropriate form.
Action: If the FDD does not move to the diverted-flow position when the frequency pen of the flow rate recorder-controller indicates a flow-diversion, milk plant personnel shall make a modification to the FDD or the STLR recorder-controller as required. If after adjustment the pasteurization system fails this test, the pasteurization system shall not be allowed to operate until the cause of this failure has been corrected and compliance has been verified by the Health Officer; or in the case of HACCP listed milk plants, qualified industry personnel acceptable to the Health Officer in compliance with Rule 420-3-16-.10(21-22); or on an emergency basis, an industry temporary testing and sealing program authorized by the Health Officer in compliance with Rule 420-3-16-.10(21-22).
11.2C CONTINUOUS-FLOW PASTEURIZATION SYSTEMS UTILIZING A MAGNETIC FLOW METER BASED TIMING SYSTEM – HOLDING TUBES AND LOW FLOW/LOSS-OF-SIGNAL ALARM
Application: To all continuous-flow pasteurization systems using a magnetic flow meter based timing system in lieu of a timing pump.
Frequency: Upon installation; at least once each six (6) months thereafter; whenever any alteration is made affecting the flow rate in the holding tube; or whenever the regulatory seal on the low flow/loss-of-signal flow alarm has been broken.
Criteria: Forward-flow occurs only when flow rates are above the low flow/loss-of-signal alarm set point.
Apparatus: No supplementary materials required.
Method: By observing the actions of the frequency pen on the flow rate recorder-controller and the position of the FDD.
Procedure:
- Operate the pasteurization system using water in forward-flow at a flow rate below the high flow alarm set point and above the low flow/loss-of-signal alarm set point.
Note: The appropriate temperature sensing elements may be placed in a water, oil, or other suitable media bath to simulate the processing pasteurization temperature within the holding tube as an alternative to heating water in the pasteurization system above the minimum legal pasteurization temperature.
-
Disrupt the power to the magnetic flow meter to activate the loss-of-signal alarm or decrease the flow through the flow meter to a flow rate below the low flow alarm set point. Observe that the FDD assumes the diverted-flow position and that the frequency pen(s) on the STLR and the flow rate recorder-controller(s) assumed the diverted-flow position.
-
Record the results of this test and the low flow/loss-of-signal alarm set point, if applicable, on the appropriate form.
Action: If the FDD does not divert or the frequency pens do not assume the diverted-flow position, milk plant personnel shall make an adjustment to the low flow/loss-of-signal alarm or a modification to the FDD, the STLR, or flow rate recorder-controller as required. If after adjustment the pasteurization system fails this test, the pasteurization system shall not be allowed to operate until the cause of this failure has been corrected and compliance has been verified by the Health Officer; or in the case of HACCP listed milk plants, qualified industry personnel acceptable to the Health Officer in compliance with Rule 420-3-16-.10(21-22); or on an emergency basis, an industry temporary testing and sealing program authorized by the Health Officer in compliance with Rule 420-3-16-.10(21-22).
11.2D CONTINUOUS-FLOW PASTEURIZATION SYSTEMS UTILIZING A MAGNETIC FLOW METER BASED TIMING SYSTEM – HOLDING TUBES AND FLOW RATE CUT-IN AND CUT-OUT
Application: To all HTST continuous-flow pasteurization systems using a magnetic flow meter based timing system in lieu of a timing pump.
Frequency: Upon installation; at least once each six (6) months thereafter; whenever any alteration is made affecting the pasteurization holding time, the velocity of the flow or the capacity of the holding tube; whenever a check of the capacity of the holding tube indicates a speedup; or whenever the regulatory seal on the high flow and/or low flow/loss-of-signal alarm(s) has been broken.
Criteria: Forward-flow occurs only when flow rates are below the high flow alarm set point and above the low flow/loss-of-signal alarm set point.
Apparatus: No supplementary materials required.
Method: By observing the flow rate recorder-controller’s readings along with the action of the frequency pen on the flow rate recorder-controller and the position of the FDD.
Procedure:
- Operate the pasteurization system using water above the minimum legal pasteurization temperature in forward-flow at a flow rate below the high flow alarm set point and above the low flow/loss-of-signal alarm set point.
Note: The appropriate temperature sensing elements may be placed in a water, oil, or other suitable media bath to simulate the processing pasteurization temperature within the holding tube as an alternative to heating water in the pasteurization system above the minimum legal pasteurization temperature.
-
Using the flow rate recorder-controller, slowly increase the flow rate until the frequency pen on the flow rate recorder-controller indicates a flow-diversion because the high flow alarm set point had been exceeded. The FDD shall assume the diverted-flow position. Observe the flow rate reading from the flow rate recorder-controller the instant forward-flow cut-out occurs, as indicated by the flow rate recorder-controller’s frequency pen.
-
With the pasteurization system operating on water above the minimum legal pasteurization temperature and with the FDD in the diverted-flow position due to exceeding the high flow alarm set point, slowly decrease the flow rate until the frequency pen on the flow rate recorder-controller indicates the start of the FDD’s forward-flow movement, which indicates the flow rate cut-in point. Because of the time delay described in Test 11.2E, the FDD will not move immediately to the forward-flow position. Observe the flow rate reading from the flow rate recorder-controller the instant flow rate cut-in occurs, as indicated by the flow rate recorder-controller’s frequency pen.
-
Record the flow rate cut-in and cut-out results of this test on the appropriate form.
Action: If the flow rate cut-in or cut-out point(s) occurs at a flow rate equal to or greater than the value at which the pasteurization holding time was measured, milk plant personnel shall adjust the high flow alarm to a lower set point and this test shall be repeated. If after adjustment the pasteurization system fails this test, the pasteurization system shall not be allowed to operate until the cause of this failure has been corrected and compliance has been verified by the Health Officer; or in the case of HACCP listed milk plants, qualified industry personnel acceptable to the Health Officer in compliance with Rule 420-3-16-.10(21-22); or on an emergency basis, an industry temporary testing and sealing program authorized by the Health Officer in compliance with Rule 420-3-16-.10(21-22).
11.2E CONTINUOUS-FLOW PASTEURIZATION SYSTEMS UTILIZING A MAGNETIC FLOW METER BASED TIMING SYSTEM -HOLDING TUBES AND TIME DELAY
Application: To all HTST continuous-flow pasteurization systems with a FDD located at the end of the holding tube that use a MFMBTS in lieu of a timing pump.
Frequency: Upon installation; at least once each six (6) months thereafter; whenever any alteration is made affecting the pasteurization holding time, the velocity of the flow, or the capacity of the holding tube; whenever a check of the capacity of the holding tube indicates a speedup; or whenever the regulatory seal on the flow alarm has been broken.
Criteria: Following the determination of the flow rate cut-in as described in Test 11.2D, forward-flow shall not occur until all milk and/or milk product in the holding tube has been held at or above the minimum legal pasteurization temperature for at least the minimum legal pasteurization holding time.
Apparatus: An accurate time measuring device.
Method: Set the time delay equal to or greater than the minimum legal pasteurization holding time.
Procedure:
- Operate the pasteurization system using water above the minimum legal pasteurization temperature in forward-flow at a flow rate below the high flow alarm set point and above the low flow/loss-of-signal alarm set point.
Note: The appropriate temperature sensing elements may be placed in a water, oil, or other suitable media bath to simulate the processing pasteurization temperature within the holding tube as an alternative to heating water in the pasteurization system above the minimum legal pasteurization temperature.
-
Using the flow rate recorder-controller, slowly increase the flow rate until the frequency pen on the flow rate recorder-controller indicates a flow-diversion and the FDD moves to the diverted-flow position. There shall not be any time delay between the movements of the flow rate recorder-controller’s frequency pen and the FDD.
-
With the pasteurization system operating on water above the minimum legal pasteurization temperature and with the FDD in the diverted-flow position due to exceeding the high flow alarm set point, slowly decrease the flow rate.
-
Start the accurate time measuring device the instant the flow rate recorder-controller’s frequency pen indicates flow rate cut-in.
-
Stop the accurate time measuring device the instant the FDD starts to move to the forward-flow position.
-
Record the results of this test on the appropriate form.
Action: If the time delay is less than the minimum pasteurization holding time, milk plant personnel shall increase the time setting on the time delay and Test 11.2E shall be repeated. If after adjustment the pasteurization system fails this test, the pasteurization system shall not be allowed to operate until the cause of this failure has been corrected and compliance has been verified by the Health Officer; or in the case of HACCP listed milk plants, qualified industry personnel acceptable to the Health Officer in compliance with Rule 420-3-16-.10(21-22); or on an emergency basis, an industry temporary testing and sealing program authorized by the Health Officer in compliance with Rule 420-3-16-.10(21-22).
11.2F CONTINUOUS-FLOW PASTEURIZATION SYSTEMS UTILIZING A MAGNETIC FLOW METER BASED TIMING SYSTEM - HIGH FLOW ALARM RESPONSE TIME
Application: To all continuous-flow pasteurization (HTST) systems using a magnetic flow meter based timing system in lieu of a timing pump.
Frequency: Upon installation; at least once each six (6) months thereafter; whenever any alteration is made affecting the pasteurization holding time, the velocity of the flow, or the capacity of the holding tube; whenever a check of the capacity of the holding tube indicates a speedup; or whenever the regulatory seal on the flow alarm has been broken.
Criteria: When the flow rate equals or exceeds the value at which the pasteurization holding time was measured, the high flow alarm shall cause the FDD to assume the diverted-flow position within one (1) second.
Apparatus: An accurate time measuring device.
Method: Rapidly increase the flow rate to exceed the high flow alarm and verify that the FDD moves to the diverted-flow position within one (1) second.
Procedure:
- Operate the pasteurization system, using water above the minimum legal pasteurization temperature, in forward-flow at a flow rate 25 percent below the high flow alarm set point as determined in Test 11.2B Procedure 2.
Note: The appropriate temperature sensing elements may be placed in a water, oil, or other suitable media bath to simulate the processing pasteurization temperature within the holding tube as an alternative to heating water in the pasteurization system above the minimum legal pasteurization temperature. The observation and recording of the high flow alarm response time shall be conducted as described in Procedures 3 through 6 below.
-
Identify the high flow alarm set point on the flow rate recorder-controller chart. This may be accomplished by inscribing a line intersecting the recorded flow arc at the pen location or any other method acceptable to the Health Officer.
-
Increase the pasteurization system flow rate as rapidly as practical to a point above the high flow alarm set point.
-
Start the accurate time measuring device when the flow rate recorder-controller’s recording pen exceeds the high flow alarm set point.
-
Stop the accurate time measuring device when the FDD has moved to the diverted-flow position.
-
Record the high flow alarm response time on the appropriate form.
Action: If the response time exceeds one (1) second, immediate action shall be taken by milk plant personnel to correct this FDD deficiency. If after adjustment the pasteurization system fails this test, the pasteurization system shall not be allowed to operate until the cause of this failure has been corrected and compliance has been verified by the Health Officer; or in the case of HACCP listed milk plants, qualified industry personnel acceptable to the Health Officer in compliance with Rule 420-3-16-.10(21-22); or on an emergency basis, an industry temporary testing and sealing program authorized by the Health Officer in compliance with Rule 420-3-16-.10(21-22).
11.3 CALCULATED PASTEURIZATION HOLDING TIME FOR HHST PASTEURIZATION SYSTEMS USING INDIRECT HEATING
Application: To all HHST pasteurization systems using indirect heating.
Frequency: Upon installation; at least once each six (6) months thereafter; whenever any alteration is made affecting the pasteurization holding time, the velocity of the flow, such as the replacement of the timing pump, motor, belt, drive or driven pulley, decrease in the number of HHST pasteurization system heat-exchange plates, or the capacity of the holding tube; whenever a check of the capacity of the holding tube indicates a speedup; or whenever the regulatory seal on the timing pump speed setting has been broken.
Criteria: Every particle of milk and/or milk product shall be held for the applicable minimum pasteurization holding time in both the forward-flow and diverted-flow positions.
Apparatus: No supplementary materials required.
Method: For this test, fully developed laminar flow is assumed and the required holding tube length shall be calculated from an experimental determination of the pumping rate. An experimental determination of the pumping rate can be accomplished by determining the time required for the pasteurization system to fill a vessel of a known volume; converting these data by division to obtain the flow rate in gallons per second; and then multiplying this value, by the proper value referenced in Table 14 to determine the required holding tube length.
TABLE 14
| Holding Tube Length - HHST Pasteurization System- Indirect Heating at a Pumping Rate of 1 gallon/second | | | | | --- | --- | --- | --- | | Pasteurization Holding | Tubing Size (inches) | | | | | 2 | 2-1/2 | 3 | | | Holding Tube Length (inches) | | | | 1.0 | 168.0 | 105.0 | 71.4 | | 0.5 | 84.0 | 52.4 | 35.7 | | 0.1 | 16.8 | 10.5 | 7.14 | | 0.05 | 8.4 | 5.24 | 3.57 | | 0.01 | 1.68 | 1.05 | .714 |
Procedure:
- Operate the pasteurization system on water, in forward-flow, with all flow-promoting devices, which are capable of causing flow through the FDD operating at their maximum capacity and all flow-impeding devices adjusted or bypassed to provide the minimum amount of resistance to the flow through the pasteurization system.
There shall not be any leakage on the suction side of the timing pump.
a. For a variable speed timing pump, adjust the timing pump to its maximum capacity, preferably with a new belt and full size impellers.
b. For a homogenizer used as the timing pump, check the homogenizer for its regulatory seal(s) and gears or pulley identification.
c. For AC variable speed timing pump, check the timing pump’s control box for its regulatory seal(s).
Note: For pasteurization systems that employ a liquid ingredient injection (slurry) system as described in Appendix H, the slurry injection pump shall be energized and running at its maximum speed and the slurry supply tank shall be completely filled with water.
-
Measure the time required to deliver a known volume of water at the discharge outlet of the pasteurization system. Repeat the test until the measurements are consistent.
-
Repeat Procedures 1 and 2 in diverted-flow by collecting the water at the pasteurization system’s diverted-flow discharge.
Note: Procedure 3 is not required for HHST pasteurization systems with magnetic flow meter based timing systems.
-
Select the highest flow rate, the shortest delivery time for the known volume, and calculate the flow rate in gallons per second by dividing the known volume by the time required to collect the known volume. Multiply this value with the appropriate value referenced in Table 14 to determine the required holding tube length for the pasteurization system.
-
The holding tube may include fittings. The centerline length of the fitting is treated as an equivalent length of straight pipe. The centerline distance may be measured by forming a flexible steel tape along the centerline of the fitting. Determine the total length of the holding tube by adding the equivalent lengths of the fittings to the measured lengths of straight pipe.
Note: The holding tube shall be arranged to have a continuously upward slope in the direction of flow of not less than 2.1 centimeters (0.25 of an inch) per foot. If the indicating temperature sensing element is located at the beginning of the holding tube, the entire length of the holding tube shall be protected against heat loss by a material that is impervious to water.
- When the actual holding tube length is equivalent to or greater than the calculated minimum holding tube length, record the number and type of fittings, the number and length of straight pipe, the holding tube configuration, and the results on the appropriate Form. If the actual holding tube length is not equivalent or greater than the calculated minimum holding tube length, refer to Action noted below.
Alternate Procedure for Measuring the Flow Rate: Suspend a sanitary dipstick in the constant-level tank and operate the pasteurization system at its maximum flow capacity. Record the time that is required for the water level in the constant-level tank to drop two (2) identified graduations on the dipstick. The volume of water is calculated from the dimensions of the constant-level tank and the drop in water level. The flow rate is determined as follows:
-
Divide the volume of water, in gallons, removed from the constant-level tank by the time, in seconds, required to remove the volume of water.
-
Then use this flow rate to calculate the required holding tube length as provided in Procedures 3 and 4 above.
Alternate Procedures for the Determination of the Holding Tube Length for Non-Standard Pipe Size: The holding tube length may be accurately calculated from the following equation:
L = 588 Qt/D2
Where: L = Holding tube length (inches) Q = Pumping rate (gallons per second) t = Pasteurization holding time standard (seconds) D = Internal diameter of the holding tube (inches)
Note: Table 15 provides the internal pipe diameters for piping in a HHST pasteurization system’s holding tube with nominal external diameters of 2.0, 2.5, 3.0, and 4.0 inches. Internal diameters for pasteurization system’s holding tubes designed for high pressure and for holding tubes with external piping sizes not listed in Table 15, shall be individually determined and the minimum holding tube length calculated using the above formula.
TABLE 15
| Table 15. Dimension for Standard Stainless Steel Sanitary Tubing1 | | | --- | --- | | Nominal External Diameter2 | Internal Diameter2 | | 2.0 | 1.87 | | 2.5 | 2.37 | | 3.0 | 2.87 | | 4.0 | 3.83 |
Abstracted from Table 6.1 “Pipe and Heat Exchanger Tube Dimensions,” Fundamentals of Food Process Engineering, 1979, R. T. Toledo, AVI Press 1Measurements are in inches.
After the minimum required holding tube length is obtained from the calculation above, the length of the holding tube is measured to determine that it is at least as long as the calculated length. Record the number and type of fittings, the number and length of straight pipe, and the holding tube configuration results on the appropriate form.
Action: If the length of the holding tube is shorter than the calculated required minimum length, reseal the timing system at a slower maximum speed based on new calculations with this slower maximum speed or have milk plant personnel lengthen the holding tube, or both, and repeat the test procedure previously used. If after adjustment the pasteurization system fails this test, the pasteurization system shall not be allowed to operate until the cause of this failure has been corrected and compliance has been verified by the Health Officer; or in the case of HACCP listed milk plants, qualified industry personnel acceptable to the Health Officer in compliance with Rule 420-3-16-.10(21-22); or on an emergency basis, an industry temporary testing and sealing program authorized by the Health Officer in compliance with Rule 420-3-16-.10(21-22).
11.4 CALCULATED PASTEURIZATION HOLDING TIME FOR HHST PASTEURIZATION SYSTEMS USING DIRECT HEATING
Application: To all HHST pasteurization systems using direct heating.
Frequency: Upon installation; at least once each six (6) months thereafter; whenever any alteration is made affecting the pasteurization holding time, the velocity of the flow, such as replacement of the timing pump, motor, belt, drive or driven pulley, decrease in number of heat-exchange plates, or the capacity of the holding tube; whenever a check of the capacity of the holding tube indicates a speedup; or whenever the regulatory seal on the timing pump speed setting has been broken.
Criteria: Every particle of milk and/or milk product shall be held for the appropriate minimum pasteurization holding time in both the forward-flow and diverted-flow positions.
Apparatus: No supplementary materials required.
Method: For this test, fully developed laminar flow and a temperature increase by the steam injection of 49°C (120°F) are assumed and the processor chooses the temperature-time standard and the required holding tube length is calculated from an experimental determination of the pumping rate.
Procedure:
- Operate the pasteurization system on water in forward-flow with all flow-promoting devices which are capable of causing flow through the FDD operating at their maximum capacity and all flow-impeding devices adjusted or bypassed to provide the minimum amount of resistance to the flow through the pasteurization system. There shall not be any leakage on the suction side of the timing pump.
a. For a variable speed timing pump, adjust the timing pump to its maximum capacity, preferably with a new belt and full size impellers.
b. For a homogenizer used as the timing pump, check the homogenizer for its regulatory seal(s) and gears or pulley identification.
c. For AC variable speed timing pump, check the timing pump’s control box for its regulatory seal(s).
d. When vacuum equipment is present, operate the vacuum equipment at maximum vacuum rate.
Note: For pasteurization systems that employ a liquid ingredient injection (slurry) system as described in Appendix H, the slurry injection pump shall be energized and running at its maximum speed and the slurry supply tank shall be completely filled with water.
-
Measure the time required to deliver a known volume of water at the discharge outlet of the pasteurization system. Repeat the test until the measurements are consistent.
-
Repeat Procedures 1 and 2 in diverted-flow by collecting the water at the pasteurization system’s diverted-flow discharge.
Note: Procedure 3 is not required for HHST pasteurization systems with magnetic flow meter based timing systems.
- Select the highest flow rate, the shortest delivery time for the known volume and calculate the flow rate in gallons per second by dividing the known volume by the time required to collect the known volume. Multiply this value with the appropriate value referenced in Table 16 to determine the required holding tube length for the pasteurization system.
TABLE 16
| Holding Tube Length - HHST Pasteurization System- Direct Heating at a Pumping Rate of 1 gallon/second | | | | | --- | --- | --- | --- | | Pasteurization Holding | Tubing Size (inches) | | | | | 2 | 2-1/2 | 3 | | | Holding Tube Length (inches) | | | | 1.0 | 188.0 | 118.0 | 80.0 | | 0.5 | 94.0 | 59.0 | 40.0 | | 0.1 | 18.8 | 11.8 | 8.0 | | 0.05 | 9.4 | 5.90 | 4.0 | | 0.01 | 1.88 | 1.18 | 0.8 |
- The holding tube may include fittings. The center line length of the fitting is treated as an equivalent length of straight pipe. The center line distance may be measured by forming a flexible steel tape along the center line of the fitting. Determine the total length of the holding tube by adding the equivalent lengths of the fittings to the measured lengths of straight pipe.
Note: The holding tube shall be arranged to have a continuously upward slope in the direction of flow of not less than 2.1 centimeters (0.25 of an inch) per foot. If the indicating temperature sensing element is located at the beginning of the holding tube, the entire length of the holding tube shall be protected against heat loss by a material that is impervious to water.
- When the actual holding tube length is equivalent to or greater than the calculated minimum holding tube length, record the number and type of fittings, the number and length of straight pipe, the holding tube configuration, and the results on the appropriate form. If the actual holding tube length is not equivalent or greater than the calculated minimum holding tube length, refer to Action noted below.
Alternate Procedure for Measuring the Flow Rate: Suspend a sanitary dipstick in the constant-level tank and operate the pasteurization system at its maximum flow capacity. Record the time that is required for the water level in the constant-level tank to drop two (2) identified graduations on the dipstick. The volume of water is calculated from the dimensions of the constant-level tank and the drop in water level. The flow rate is determined as follows:
-
Divide the volume of water, in gallons, removed from the constant-level tank by the time, in seconds, required to remove the volume of water.
-
Then use this flow rate to calculate the required holding tube length as provided in Procedures 3 and 4 above.
Alternate Procedures for the Determination of the Holding Tube Length for Non-Standard Pipe Size:
The holding tube length may also be accurately calculated from the following equation:
L = (588 Qt x 1.12)/D2
Where: L = Holding tube length (inches) Q = Pumping rate (gallons per second) t = Pasteurization holding time standard (seconds) 1.12 = 12% expansion for steam D = Internal diameter of the holding tube (inches)
Note: Table 15 provides the internal pipe diameters for piping in a HHST pasteurization system’s holding tube with nominal external diameters of 2.0, 2.5, 3.0, and 4.0 inches. Internal diameters for pasteurization system’s holding tubes designed for high pressure and for holding tubes with external piping sizes not listed in Table 15 shall be individually determined and the minimum holding tube length calculated using the above formula.
After the minimum required holding tube length is obtained from the calculation above, the length of the holding tube is measured to determine that it is at least as long as the calculated length. Record the number and type of fittings, the number and length of straight pipe, and the holding tube configuration results on the appropriate form.
Action: If the length of the holding tube is shorter than the calculated required minimum length, reseal the timing system at a slower maximum speed based on new calculations with this slower maximum speed or have milk plant personnel lengthen the holding tube, or both, and repeat the test procedure previously used. If after adjustment the pasteurization system fails this test, the pasteurization system shall not be allowed to operate until the cause of this failure has been corrected and compliance has been verified by the Health Officer; or in the case of HACCP listed milk plants, qualified industry personnel acceptable to the Health Officer in compliance with Rule 420-3-16-.10(21-22); or on an emergency basis, an industry temporary testing and sealing program authorized by the Health Officer in compliance with Rule 420-3-16-.10(21-22).
11.5 HHST PASTEURIZATION SYSTEMS HOLDING TIME USING DIRECT STEAM INFUSION HEATING WITH A STEAM PRESSURE RELIEF POP-OFF VALVE AND A VACUUM CHAMBER ORIFICE IN PLACE OF A TIMING PUMP
Application: To all HHST pasteurization systems using direct steam infusion heating and using a steam pressure relief pop-off valve and a vacuum chamber orifice in place of a timing pump.
Frequency: Upon installation; at least once each three (3) months thereafter; whenever the steam infusion shell or feed line, pressure relief pop-off valve, or vacuum chamber orifice has been repaired or replaced; or whenever the regulatory seal has been broken.
Criteria: Every particle of milk and/or milk product shall be held for the applicable minimum pasteurization holding time in both the forward-flow and diverted-flow positions.
Apparatus: No supplementary materials required.
Method:
-
The steam infusion shell or feed line shall be equipped with a pressure relief pop-off valve. This pressure relief pop-off valve shall be located and sized so that the total pressure inside the steam infusion shell or feed line can never exceed the set point on this pressure relief pop-off valve.
-
An orifice or restriction which is permanently installed in a noticeable fitting shall be placed in the holding tube just prior to the vacuum chamber. The opening in the orifice or restriction shall be sized to ensure a minimum milk and/or milk product residence pasteurization holding time at least as long as that specified in the chosen HHST pasteurization standard.
-
The size of the opening in the orifice or restriction and the setting of the pressure relief valve shall be determined by trial and error. Once an appropriate maximum flow rate has been determined and a minimum legal pasteurization holding time has been calculated, both the orifice or restriction and the steam pressure setting on the pressure relief pop-off valve shall be sealed by the Health Officer so that neither can be changed or altered.
Procedure:
- Operate the pasteurization system on water in forward-flow with all flow-promoting devices, which are capable of causing flow through the FDD operating at their maximum capacity and all flow-impeding devices adjusted or bypassed to provide the minimum amount of resistance to the flow through the pasteurization system.
There shall not be any leakage on the suction side of the timing pump.
a. For a variable speed timing pump, adjust the timing pump to its maximum capacity, preferably with a new belt and full size impellers.
b. For a homogenizer used as the timing pump, check the homogenizer for its regulatory seal(s) and gears or pulley identification.
c. For AC variable speed timing pump, check the timing pump’s control box for its regulatory seal(s).
Note: For pasteurization systems that employ a liquid ingredient injection (slurry) system as described in Appendix H, the slurry injection pump shall be energized and running at its maximum speed and the slurry supply tank shall be completely filled with water.
-
The steam pressure in the steam infusion shell or feed line shall be raised to a level just below the pressure relief pop-off point of the pressure relief pop-off valve.
-
Any back-pressure valves or other variable restrictions in the holding tube shall be placed into the fully open position.
-
All air bleeds to the vacuum chamber shall be closed so that the vacuum chamber will be operating under maximum vacuum.
-
Operate the pasteurization system at its maximum flow for approximately fifteen (15) minutes to purge air from the pasteurization system.
-
Measure the time required to deliver a known volume of water at the discharge outlet of the pasteurization system. Repeat the test until the measurements are consistent.
-
Repeat Procedures 1 through 5 in diverted-flow by collecting the water at the pasteurization system’s diverted-flow discharge.
Note: Procedure 7 is not required for HHST pasteurization systems with magnetic flow meter based timing systems.
-
Select the highest flow rate, the shortest delivery time for the known volume, and calculate the flow rate in gallons per second by dividing the known volume by the time required to collect the known volume. Multiply this value with the appropriate value referenced in Table 16 to determine the required holding tube length for the pasteurization system.
-
The holding tube may include fittings. The centerline length of the fitting is treated as an equivalent length of straight pipe. The centerline distance may be measured by forming a flexible steel tape along the centerline of the fitting. Determine the total length of the holding tube by adding the equivalent lengths of the fittings to the measured lengths of straight pipe.
Note: The holding tube shall be arranged to have a continuously upward slope in the direction of flow of not less than 2.1 centimeters (0.25 of an inch) per foot. If the indicating temperature sensing element is located at the beginning of the holding tube, the entire length of the holding tube shall be protected against heat loss by a material that is impervious to water.
- If the actual holding tube length is equivalent to or greater than the calculated minimum holding tube length, record the number and type of fittings, the number and length of straight pipes, and the holding tube configuration and results on the appropriate form.
Action: If the length of the holding tube is shorter than the calculated required minimum length, reseal the timing system at a slower maximum speed based on new calculations with this slower maximum speed or have milk plant personnel lengthen the holding tube, or both, and repeat the test procedure previously used. If after adjustment the pasteurization system fails this test, the pasteurization system shall not be allowed to operate until the cause of this failure has been corrected and compliance has been verified by the Health Officer; or in the case of HACCP listed milk plants, qualified industry personnel acceptable to the Health Officer in compliance with Rule 420-3-16-.10(21-22); or on an emergency basis, an industry temporary testing and sealing program authorized by the Health Officer in compliance with Rule 420-3-16-.10(21-22).
TEST 12
THERMAL-LIMIT-CONTROLLER FOR CONTROL - SEQUENCE LOGIC
References: Rule 420-3-16-.10(18) and Rule 420-3-16-.10(21-22)
Thermal-limit-controllers used with HTST and HHST pasteurization systems that have the FDD located downstream of the pasteurized regenerator section(s) and/or cooler section shall be tested by one (1) of the following applicable tests at the frequency prescribed.
12.1 PASTEURIZATION - INDIRECT HEATING
Application: To all HTST and HHST pasteurization systems that have the FDD located downstream of the pasteurized regenerator section(s) and/or cooler section and using indirect heating.
Frequency: Upon installation; at least once each three (3) months thereafter; whenever the thermal-limit-controller has been repaired or replaced; or whenever the regulatory seal has been broken.
Criteria: The pasteurization system shall not operate in forward-flow until the milk and/or milk product-contact surfaces downstream from the holding tube have been sanitized. Upon start-up, milk and/or milk product-contact surfaces shall be exposed to fluid at the applicable required pasteurization temperature for at least the applicable required pasteurization or sterilization time. If any public health control causes the FDD to assume the diverted-flow position due to incorrect temperature, pressure, or flow, forward-flow shall not be re-achieved until the milk and/or milk product-contact surfaces downstream from the holding tube have been re-sanitized or re-sterilized as appropriate.
Apparatus: A constant temperature bath of water, oil, or other suitable media and the test light from the pneumatic testing device described in Test 9.1 PRESSURE SWITCHES may be used to check the control-sequence logic of the thermal-limit-controller.
Method: The control-sequence logic of the thermal-limit-controller is determined by monitoring the electric signal from the thermal-limit-controller during a series of immersions and removals of the two (2) sensing elements located at the FDD and in the holding tube from a media bath heated above the cut-in temperature.
Procedure:
- Heat the media bath to a constant temperature, a few degrees above the cut-in temperature of the thermal-limit-controller. Wire the test light in series with the signal from the thermal-limit-controller to the FDD.
Note: Some processors may have time delays built into their control logic in excess of that required for public health reasons. If so equipped, by-pass these time delays or account for their effect in delaying forward-flow.
-
Immerse the sensing element from the FDD into the media bath, which is above the cut-in temperature. The test light shall remain unlit, indicating diverted-flow. Leave this sensing element in the media bath.
-
Immerse the sensing element from the holding tube into the media bath. The test light shall light up, indicating forward-flow after a minimum time delay of one (1) second for continuous-flow pasteurization systems.
-
Remove the sensing element from the FDD from the media bath. The test light shall remain lit, indicating forward-flow.
-
Remove the sensing element from the holding tube from the media bath. The test light shall turn off immediately, indicating diverted-flow.
-
Re-immerse the sensing element from the holding tube into the media bath. The test light shall remain unlit, indicating diverted-flow.
-
Record the results of the test on the appropriate form.
Action: If the control-sequence logic of the thermal-limit-controller does not follow these Procedures, the instrument shall be reconfigured to conform to this logic. If after reconfiguration, the pasteurization system fails this test, the pasteurization system shall not be allowed to operate until the cause of this failure has been corrected and compliance has been verified by the Health Officer; or in the case of HACCP listed milk plants, qualified industry personnel acceptable to the Health Officer in compliance with Rule 420-3-16-.10(21-22); or on an emergency basis, an industry temporary testing and sealing program authorized by the Health Officer in compliance with Rule 420-3-16-.10(21-22).
12.2 PASTEURIZATION - DIRECT HEATING
Application: To all HTST and HHST pasteurization systems that have the FDD located downstream of the pasteurized regenerator section(s) and/or cooler section and using direct heating.
Frequency: Upon installation; at least once each three (3) months thereafter; whenever the thermal-limit-controller has been repaired or replaced; or whenever the regulatory seal has been broken.
Criteria: The pasteurization system shall not operate in forward-flow until the milk and/or milk product-contact surfaces downstream from the holding tube have been sanitized. Upon start-up, milk and/or milk product-contact surfaces shall be exposed to fluid at the applicable required pasteurization temperature for at least the applicable required pasteurization or sterilization time. If the milk and/or milk product temperature falls below the applicable pasteurization standard in the holding tube, forward-flow shall not be re-achieved until the milk and/or milk product-contact surfaces downstream from the holding tube have been re-sanitized or re-sterilized as appropriate.
Apparatus: A constant temperature bath of water, oil, or other suitable media and the test light from the pneumatic testing device described in Test 9.1 PRESSURE SWITCHES can be used to check the control-sequence logic of the thermal-limit-controller.
Method: The control-sequence logic of the thermal-limit-controller is determined by monitoring the electric signal from the thermal-limit-controller during a series of immersions and removals of the three (3) sensing elements, located at the FDD, vacuum chamber, and in the holding tube from a media bath heated above the cut-in temperature.
Procedure:
- Heat a media bath to a constant temperature, a few degrees above the cut-in temperature on the thermal-limit-controller. Wire the test light in series with the signal from the thermal-limit-controller to the FDD.
Note: Some processors have time delays built into their control logic in excess of that required for public health reasons. If so equipped, bypass these time delays or account for their effect in delaying forward-flow. Before performing this test, make sure the pressure switches which shall be closed to achieve forward-flow have also been bypassed.
-
Immerse the sensing element from the FDD into the media bath, which is above the cut-in temperature. The test light shall remain unlit, indicating diverted-flow. Remove this sensing element from the media bath.
-
Immerse the sensing element from the vacuum chamber into the media bath. The test light shall remain unlit, indicating diverted-flow. Remove this sensing element from the media bath.
-
Immerse the two (2) sensing elements from the vacuum chamber and the FDD into the media bath. The test light shall remain unlit, indicating diverted-flow. Leave these two (2) sensing elements in the media bath.
-
Immerse the third sensing element from the holding tube into the media bath. The test light shall light up, indicating forward-flow, after a minimum time delay of one (1) second for continuous-flow pasteurization systems.
-
Remove the sensing element from the FDD from the media bath. The test light shall remain lit, indicating forward-flow.
-
Remove the sensing element from the vacuum chamber from the media bath. The test light shall remain lit, indicating forward-flow.
-
Remove the remaining sensing element from the holding tube from the media bath. The test light shall immediately turn off, indicating diverted-flow.
-
Re-immerse the sensing element from the holding tube into the media bath. The test light shall remain unlit, indicating diverted-flow.
-
Record the results of the test on the appropriate form.
Action: If the control-sequence logic of the thermal-limit-controller does not follow these Procedures, the instrument shall be reconfigured to conform to this logic. If after reconfiguration the pasteurization system fails this test, the pasteurization system shall not be allowed to operate until the cause of this failure has been corrected and compliance has been verified by the Health Officer; or in the case of HACCP listed milk plants, qualified industry personnel acceptable to the Health Officer in compliance with Rule 420-3-16-.10(21-22); or on an emergency basis, an industry temporary testing and sealing program authorized by the Health Officer in compliance with Rule 420-3-16-.10(21-22).
TEST 13
SETTING OF CONTROL SWITCHES FOR MILK AND/OR MILK PRODUCT PRESSURE IN THE HOLDING TUBE
Reference: Rule 420-3-16-.10(18) and Rule 420-3-16-.10(21-22)
Application: To all HHST pasteurization systems which are capable of operating with milk and/or milk product in forward-flow mode with less than 518 kPa (75 psig) pressure in the holding tube.
Frequency: Upon installation; at least once each three (3) months thereafter; whenever the pressure switch has been repaired or replaced; whenever the operating temperature is changed; or whenever the pressure switch regulatory seal has been broken.
Criteria: The pasteurization system shall not operate in forward-flow unless the product pressure in the holding tube is at least 69 kPa (10 psi) above the boiling pressure of the milk and/or milk product.
Apparatus: The sanitary pressure gauge and the pneumatic testing device described in Test 9.1 PRESSURE SWITCHES can be used for checking and adjusting the pressure switch setting.
Method: The pressure switch is checked and adjusted so as to prevent forward-flow unless the milk and/or milk product pressure in the holding tube is at least 69 kPa (10 psi) above the boiling pressure of the milk and/or milk product.
Procedure:
-
Using Figure 57 determine the pressure switch setting necessary for the operating temperature being used in the pasteurization system; do not use the diversion temperature. Install the sanitary pressure gauge and the pressure switch sensing element on the pneumatic testing device.
-
Remove the regulatory seal and cover to expose the adjustment mechanism on the pressure switch. Place the test light in series with the pressure switch contacts or use some other method to monitor the cut-in signal.
-
Apply air pressure to the pressure switch sensing element and determine the pressure gauge reading at the cut-in point of the pressure switch, which shall turn on the test light. If the pressure switch is short circuited, the test light will light up before the air pressure is applied.
-
Determine that the cut-in pressure on the pressure switch is equivalent to or greater than the required pressure from Figure 57. If adjustment is necessary, refer to the manufacturer's instructions.
-
After the necessary adjustment is made, repeat the test.
-
Record the results of the test on the appropriate form.
Action: If forward-flow is achieved with less than 69 kPa (10 psi) above the boiling point of the milk and/or milk product in the holding tube, adjust the pressure setting and retest. If after adjustment the pasteurization system fails this test, the pasteurization system shall not be allowed to operate until the cause of this failure has been corrected and compliance has been verified by the Health Officer; or in the case of HACCP listed milk plants, qualified industry personnel acceptable to the Health Officer in compliance with Rule 420-3-16-.10(21-22); or on an emergency basis, an industry temporary testing and sealing program authorized by the Health Officer in compliance with Rule 420-3-16-.10(21-22).
For each HHST pasteurization system temperature, the milk and/or milk product pressure switch setting is as follows:
Figure 57. Pressure Switch Setting
This pressure switch setting shall be adjusted upward by the difference between the routine local atmospheric pressure and the atmospheric pressure at sea level.
TEST 14
SETTING THE CONTROL FOR THE DIFFERENTIAL PRESSURE CONTROLLER ACROSS THE STEAM INJECTOR
Reference: Rule 420-3-16-.10(18) and Rule 420-3-16-.10(21-22)
Application: To all HTST and HHST continuous-flow pasteurization systems using direct steam injection heating.
Frequency: Upon installation; at least once each three (3) months thereafter; whenever the differential pressure controller has been repaired or replaced; or whenever the differential pressure controller’s regulatory seal has been broken.
Criteria: The pasteurization system shall not operate in forward-flow unless the milk and/or milk product pressure drop across the steam injector is at least 69 kPa (10 psi).
Apparatus: The sanitary pressure gauge and the pneumatic testing device described in Test 9.1 PRESSURE SWITCHES can be used for checking and adjusting the differential pressure controller.
Method: Adjust the differential pressure controller to prevent forward-flow, unless the pressure differential across the steam injector is at least 69 kPa (10 psi).
Procedure:
- Calibration of the Steam Injector Differential Pressure Controller Sensing Elements:
a. Loosen the connection at both pressure sensing elements and allow for any liquid to drain through the loose connections. While the sensing elements are still in their original positions, both pointers or the digital display(s) shall be within 3.5 kPa (0.5 psi) of 0 kPa (0 psi). If not, adjust the pointer(s) or the digital display(s) to read 0 kPa (0 psi).
b. Remove both sensing elements and install them onto a tee or connect them to the pneumatic testing device. Record any difference from the zero (0 kPa [0 psi]) readings in Procedure 1.a. that may have occurred when installing the sensing elements onto the tee. Attach the tee and both sensing elements to the pneumatic testing device described in Test 9.1 PRESSURE SWITCHES and adjust the air pressure to the operating pressure used at the steam injector. Make sure that the pointer(s) or digital display(s) reading separation is within 6.9 kPa (1 psi) of that observed before the pressure was applied. If not, the differential pressure controller requires adjustment or repair.
- Setting of the Steam Injector Differential Pressure Controller:
a. Disconnect the sanitary pressure sensing element that is located after the steam injector from the pneumatic testing device and cap the opening. Leave the pressure sensing element which is installed prior to the steam injector on the pneumatic testing device.
b. Leave the other pressure sensing element open to the atmosphere, but at the same height as the pressure sensing element connected to the pneumatic testing device.
c. Wire the test light in series with the differential pressure controller microswitch or use the method provided by the instrument manufacturer to monitor the cut-in signal.
d. Apply air pressure to the pressure sensing element and determine from the test light the pressure gauge reading at the cut-in point of the differential pressure controller.
e. The differential pressure cut-in on the differential pressure controller shall be at least 69 kPa (10 psi). If adjustment is necessary, refer to the manufacturer's instructions.
f. After adjustment, repeat this test.
- Record the results of the test on the appropriate form.
Action: If after adjustment the pasteurization system fails this test, the pasteurization system shall not be allowed to operate until the cause of this failure has been corrected and compliance has been verified by the Health Officer; or in the case of HACCP listed milk plants, qualified industry personnel acceptable to the Health Officer in compliance with Rule 420-3-16-.10(21-22); or on an emergency basis, an industry temporary testing and sealing program authorized by the Health Officer in compliance with Rule 420-3-16-.10(21-22).
TEST 15
ELECTRO-MAGNETIC INTERFERENCE FROM HAND-HELD COMMUNICATION DEVICES
Application: To all electronic control devices used to assure compliance with public health safeguards on HTST and HHST continuous-flow pasteurization equipment that are installed in milk plants.
Frequency: Upon installation; at least once each three (3) months thereafter; whenever any alteration of the electronic control devices occur; or whenever the type or wattage of the hand-held communication device(s) used in that milk plant is changed. Once a hand-held communication device has been shown to cause a given electronic control device to react adversely, the electronic control device shall be repaired and re-tested using the same type hand-held communication device (refer to the Note below). If any electronic control device is altered or there is a change in the hand-held communication device(s) used, the electronic control device(s) shall be tested.
Criteria: The use of hand-held communication devices shall not have any adverse effect on the electronic control device’s public health safeguards.
Apparatus: One (1) hand-held communication device representing each make and model used in the milk plant. The hand-held communication device(s) shall be operating at maximum output and be fully charged.
Method: By observing the actual effect of the hand-held communication device on an electronic control device, it can be determined if that hand-held communication device can be used near that equipment without compromising any of the electronic control device’s public health safeguards.
Procedure:
-
Position the hand-held communication device 30.5 centimeters (12 inches) in front of the electronic control device where the public health safeguard(s) resides.
-
Place the hand-held communication device in the “send” mode for five (5) seconds and observe the effect on the electronic control device’s public health safeguard(s). There shall not be any adverse effect with the electronic control device. An adverse effect is any change that may adversely affect an electronic control device’s public health safeguard(s).
-
If applicable, repeat the test with the operator access door open.
-
Repeat the above test for each hand-held communication device identified under Apparatus.
-
Repeat the above test for each electronic control device used to regulate a pasteurization system’s public health safeguard(s).
-
Record the make and model of each hand-held communication device tested and the test results on the appropriate form.
Example: For the temperature set point, operate the pasteurization equipment on water in diverted-flow in the “Product” mode, at a steady temperature within 3ºC (5ºF) of the lowest cut-in temperature. In this example, an adverse effect is defined as the forward-flow movement of the FDD or any artificial increase in temperature.
Action: Have the milk plant check for shielding, grounding, and other installation concerns with the electronic control device and retest. Until a solution acceptable to the Health Officer can be found that does not adversely affect the electronic control device’s public health safeguard(s), the hand-held communication device cannot be used in the area of the electronic control device’s public health safeguard(s).
Note: Continuous “Hand-Held Communication Device Free” or “Radio Free” zones, etc., are not acceptable permanent solutions to hand-held communication devices which cause adverse affects to an electronic control device’s public health safeguards.
History
- Author: G. M. Gallaspy, Jr.
- Authority: Code of Ala. 1975, §§22-2-2, 22-20-7.
- Repealed and New Rule: Filed October 18, 2018; effective December 2, 2018.
Ala. Admin. Code r. 420-3-16-AJ Appendix J. Standards for the Fabrication of Single Service Containers and Closures for Milk and Milk Products
PREFACE
Single-service containers and closures have been used in the dairy industry for many years. Industry applied quality assurance controls for manufacturing and handling of the materials have made it possible for these products to reach the point of use in a sanitary condition free from toxic materials which may migrate into milk or milk products.
Within recent years, single-service container manufacturers have introduced new materials, equipment, and design concepts for these containers and closures. Evaluation of the industry's basic manufacturing and handling techniques and establishment of sanitation criteria assure that single-service containers and closures and the materials from which they are formed are safe and in compliance with bacteriological standards of 420-3-16-.10(12).
STANDARDS FOR THE FABRICATION OF SINGLE-SERVICE CONTAINERS AND CLOSURES FOR MILK AND MILK PRODUCTS
A. PURPOSE AND SCOPE
These rules will serve to ensure the production of sanitary containers and closures for milk and milk products, as defined in Rule 420-3-16.
The requirements of these rules shall apply to all blank fabricators, pre-form bottle manufacturers, single-service glass container manufacturers, converters, printers, closure manufacturers, plastic laminators, sheet formers, blow molders, vacuum formers, plastic extruders, injection molders, pre-formers, manufacturers of valves, tubes, dispensing devices, non-sterile sample containers, and any other similar plants. These also apply to fabricating plants producing a component part(s), including fabricators of film and/or closures which may become a product-contact surface and plants assembling components into a final assembled product. These requirements shall not apply to paper mills or resin manufacturing plants.
Milk and food plants manufacturing and/or selling containers to other milk plants, as defined in Rule 420-3-16, excluding milk plants that condense and/or dry milk or milk products, shall meet all the requirements of this rule.
Grade “A” milk plants, as defined in the Grade “A” Pasteurized Milk Ordinance (PMO) excluding milk plants that condense and/or dry milk or milk products, shall use single-service containers and closures from plants certified and listed in the electronic publication of the Sanitation Compliance and Enforcement Ratings of Interstate Milk Shippers (IMS List).
The PMO provides certain criteria for the listing of certified single-service manufacturers in the current publication of the IMS List (refer to Section E).
B. DEFINITIONS
The following definitions shall be employed in the application of these sanitation standards:
-
"Broke and Trim" shall mean paper and paperboard that have been discarded anywhere in the process of manufacture, such as on paper-making machines in the form of trim. This may also include unprinted trim from the converting process, provided the trim has been handled, treated, and transported in a clean, sanitary manner.
-
“Certified Single-Service Consultant (SSC)” shall mean an individual who has been certified by the Public Health Service/Food and Drug Administration (PHS/FDA), has a valid certificate of qualification to conduct the certification and listing of foreign single-service containers and/or closures for milk and/or milk products manufacturers on the IMS List, and does not have direct responsibility for the routine regulatory inspection and enforcement or regulatory auditing of the foreign single-service containers and/or closures manufacturer to be certified.
-
"Closure" shall mean a cap, lid, seal, tube, valve, lid material, or other device in or on a container used for the purpose of enclosing or dispensing the contents.
-
"Coatings" shall mean any layer or covering which is applied to the product-contact surface.
-
"Component Part" shall mean any item that by itself, does not perform any function, but when assembled with one (1) or more component parts or closures, becomes a part of the single- service container or closure. These may include, but are not limited to blanks, sheeting, valves and valve parts, tubes, dispensing devices, and sampling containers. All material used for fabrication of a component part shall meet the requirements of the FFD& CA as amended.
-
"Manufacturer" shall mean any person or company in the business of manufacturing a single-service container or closure for the packaging or sampling of a Grade “A” milk and/or milk product.
-
"Manufacturing Line" shall mean a manufacturing process such as injection molding, extrusion, blow-molding, etc.
-
"Metals" shall mean those metals that are non-toxic, nonabsorbent, and corrosion-resistant under conditions of intended use.
-
"Non-toxic Materials" shall mean materials that are free of substances which may render the product injurious to health or which may adversely affect the flavor, odor, composition, or bacteriological quality of the product and meet the requirements of the FFD&CA as amended.
-
"Paper Stock" shall mean any paper made from the following materials:
a. Paper and paperboard manufactured from clean, sanitary, virgin chemical or mechanical pulp or from "broke and trim" of such paper and paperboard, provided they have been handled, treated, and stored in a clean, sanitary manner or reclaimed fiber using acceptable or approved protocol in compliance with 21 CFR 176.260.
b. Components meeting the requirements of the FFD&CA as amended.
- "Plastic Molding, Forming, Extrusion, and Laminating Resins" shall mean:
a. Resins or an intimate admixture of resins with other ingredients which meet the requirements of the FFD&CA as amended.
b. Plastic composed solely of clean cuttings or regrind, provided they have been handled and maintained in a clean, sanitary manner.
c. Recycled plastic material when it complies with a protocol that has been reviewed and accepted by FDA.
-
"Pre-forms" shall mean a component not in final form for filling.
-
"Product-Contact Surface" shall mean those surfaces of the container or closure with which the product comes in contact.
-
"Production Scrap" shall mean material which remains from the manufacture of single-service containers or closures that has been handled or treated in such a manner that it does not comply with the definition for "broke and trim" or "regrind,” but may be collected for recycling. It may contain material such as containers or trim that have fallen on the floor.
-
"Regrind" shall mean clean plastic material that is trimmed from the container or closure, and imperfectly formed containers or closures, which result from the manufacture of single-service containers and closures, provided it is handled in a clean, sanitary manner. This may be in its trimmed or molded form and ground in a suitable grinder within the plant. It shall not include any material, container, or closure which comes from an unapproved source or whose source chemical content or treatment is unknown, or which may have poisonous or deleterious material retained in the plastic which migrates to the food at levels exceeding regulatory levels. Regrind, when transported from one (1) approved plant to another, shall be shipped in suitable, clean, sealed, properly labeled containers. This definition shall not preclude the use of regrind plastic material when it complies with a protocol that has been reviewed and accepted by FDA.
-
"Sample Set" shall mean:
a. For the rinse test, a minimum of four (4) containers shall be tested.
b. For the swab test, a minimum of four (4), 50 square centimeter areas of surface from separate containers shall be tested. In the case of containers or closures with a product-contact surface area smaller than 50 square centimeters, more than four (4) containers or closures to equal at least 50 square centimeters times four (4) shall be required to be swabbed.
-
"Sanitization" shall mean the application of any effective method or substance to properly cleaned surfaces for the destruction of pathogens and other microorganisms as far as is practicable. Such treatment shall not adversely affect the equipment, the milk and/or milk product, or the health of consumers, and shall be acceptable to the Health Officer. Methods of sanitization shall meet the requirements contained in Appendix F.
-
"Single-Service Articles" shall mean articles that are constructed wholly, in part, or in combination from paper, paperboard, molded pulp, plastic, metals, coatings, or similar materials and intended by the manufacturer for one (1) usage only.
-
"Single-Service Container" shall mean any container having a milk or milk product-contact surface and used in the packaging, handling, or storage of Grade “A” milk and/or milk products which is intended for one (1) use only.
-
“Single-Service Containers and/or Closures Manufacturer Certification” shall mean the certification conducted by a Milk Sanitation Rating Officer (SRO) for U.S. manufacturers of single-service containers and/or closures for milk and/or milk products; or a Third Party Certifier’s (TPC’s) Milk Sanitation Rating Officer (SRO) or a Certified Single-Service Consultant (SSC) for foreign manufacturers of single-service containers and/or closures for milk and/or milk products, which measures the degree to which the provisions of Appendix J of this rule are being complied with by the single-service containers and/or closures manufacturer for inclusion on the IMS List. The certification is based on compliance with the requirements of Appendix J of this rule and is conducted in accordance with the procedures set forth in the Methods of Making Sanitation Ratings of Milk Shippers and the Certifications/Listings of Single-Service Containers and/or Closures for Milk and/or Milk Products Manufacturers (MMSR).
C. BACTERIAL STANDARDS AND EXAMINATION OF SINGLE-SERVICE CONTAINERS AND CLOSURES
-
Paper stock shall meet the bacteriological standard of not more than two hundred fifty (250) colonies per gram as determined by the disintegration test. The paper stock supplier shall certify that their paper stock was manufactured in compliance with this standard. This applies only to the paper stock prior to lamination.
-
Where a rinse test can be used, the residual microbial count shall not exceed fifty (50) per container, except that in containers less than 100 mL, the count shall not exceed ten (10), or when using the swab test, not over fifty (50) colonies per 8 square inches (1 per square centimeter) of product-contact surface in three (3) out of four (4) samples taken at random on a given day. All single-service containers and closures shall be free of coliform organisms.
-
During any consecutive six (6) months, at least four (4) sample sets shall be collected in at least four (4) separate months, except when three (3) months show a month containing two (2) sampling dates separated by at least twenty (20) days, and analyzed at an Official, Commercial, or Industry Laboratory approved by the Milk Laboratory Control Agency specifically for the examinations required under these standards (refer to 420-3-16-.10(12) for sampling of containers and closures in milk plants).
-
When a single-service container or closure is made from one (1) or more component parts as defined in this document, only those final assembled products that may have product-contact surface(s) shall be sampled and tested for compliance with Section C.
-
A sample set from each manufacturing line, as defined in these rules, shall consist of a minimum of four (4) containers or closures, when the rinse test is used, or a minimum of four (4) 50 square centimeters (cm2) areas of surface, when the swab test is used.
-
The following criteria pertain to manufacturers of pre-forms and bottles preformed at one (1) plant and molded at a second plant:
a. The pre-forming plant shall be IMS Listed but sampling of the pre-forms is not required at this plant.
b. If the first pre-forming plant is also molding the containers into their final form, this plant shall be listed and the containers shall be sampled at this plant.
c. If the second plant, where containers are molded into their final form is a single-service manufacturer, this plant shall be listed and the containers shall be sampled at this plant.
d. If the second plant is a milk plant where containers are molded into their final form, for use only in that milk plant, the milk plant listing is sufficient, but the containers shall be sampled at this plant.
Procedures for obtaining samples and for the laboratory examination of these products are contained in the latest edition of SMEDP and shall be in substantial compliance with these methods. Such procedures and examinations shall be evaluated in accordance with the current revision of the EML. A list of approved laboratories may be found in the current IMS List which is published by FDA (http://www.fda.gov/food/guidanceregulation/federalstatefoodprograms/ucm2007965.htm).
D. FABRICATION PLANT STANDARDS
Note: To be used in conjunction with Form ADPH-FML-229 (Alabama Department of Public Health Manufacturing Plant Inspection Report [Single-Service Containers, refer to Appendix M]).
- FLOORS
a. The floors of all fabricating areas shall be smooth, impervious, and maintained in a state of good repair. The floors of storage rooms may be constructed of tightly joined wood.
b. The joints between the walls and floor shall be tight, impervious and shall have covered or sealed joints.
c. Where floor drains are provided, they shall be properly trapped and floors sloped to drain.
- WALLS AND CEILINGS
a. Walls and ceilings of fabricating areas shall have a smooth, cleanable, light-colored surface.
b. Walls and ceilings in fabricating and storage areas shall be kept in good repair.
c. The opening around pipes, tubes, and similar items that extend through the walls and/or ceiling shall be effectively sealed.
- DOORS AND WINDOWS
a. All outside openings shall be effectively protected against the entry of insects, rodents, dust, and airborne contamination.
b. All outer doors shall be tight and self-closing.
- LIGHTING AND VENTILATION
a. All rooms shall be adequately lighted either by natural light, artificial light, or both. A minimum of twenty (20) foot-candles (220 lux) should be maintained in fabricating areas and five (5) foot-candles (55 lux) in storage areas. Packaging, sealing, wrapping, labeling, and similar procedures are considered part of the fabricating area.
b. Ventilation shall be sufficient to prevent excessive odors and the formation of excessive water condensation.
c. The intake of all pressure ventilation systems in fabricating areas, whether they are positive or exhaust, shall be properly filtered.
- SEPARATE ROOMS
a. All fabricating areas shall be separate from non-fabricating areas to protect against contamination; provided, that if the entire plant meets all sanitation requirements and no source of cross contamination exists, separation between areas is not required.
b. All regrinding of plastic and the shredding, packaging, or baling of paper trim shall be conducted in rooms separate from the fabricating room, except that they may be conducted within the fabricating room, provided such operations are kept clean and free of dust.
- TOILET FACILITIES - SEWAGE DISPOSAL
a. Disposal of sewage and other wastes shall be in a public sewage system or in a manner in compliance with applicable state and local regulations.
b. All plumbing shall comply with the applicable state and local regulations.
c. Toilet rooms shall have solid, tight-fitting doors that are self-closing.
d. The toilet room and fixtures shall be maintained in a clean and sanitary condition and kept in good repair.
e. Each toilet room shall be well lighted and adequately ventilated. Air ventilation ducts from toilet facilities shall vent to the outside.
f. Proper handwashing facilities with hot and cold and/or warm running water shall be provided in toilet rooms.
g. All windows shall be effectively screened when open.
h. Signs shall be posted in all toilet rooms reminding employees to wash their hands before returning to work.
i. Eating and/or storage of food are prohibited in toilet rooms.
- WATER SUPPLY
a. The water supply, if from a public system, shall be approved as safe by the applicable Government Authority responsible for water quality, and in the case of individual water systems, comply with at least the specifications outlined in Appendix D. and the bacteriological standards outlined in Appendix G.
b. There shall be no cross-connection between a safe water supply and any unsafe or questionable water supply or any source of pollution through which the safe water supply might become contaminated.
c. Samples for bacteriological testing of individual water supplies are taken upon the initial approval of the physical structure; each twelve (12) months thereafter; and when any repair or alteration of the water supply system has been made. The examination of the sample shall be conducted in an Officially Designated Laboratory.
d. Water baths utilizing re-circulated water for cooling product-contact surfaces shall comply with the bacteriological standards outlined in Appendix G. and shall be tested semi-annually.
e. Records of all required water tests shall be maintained at a location acceptable to the Health Officer for a period of two (2) years.
- HANDWASHING FACILITIES
a. Hot and cold and/or warm running water, soap, individual sanitary towels or other approved hand-drying devices shall be convenient to all fabricating areas; provided, that solvent or soft soap dispensers, containing sanitizers, may be used if water is not available. When individual sanitary towels are used, covered trash containers shall be provided.
b. Handwashing facilities shall be kept clean.
- PLANT CLEANLINESS
a. The floors, walls, ceilings, overhead beams, fixtures, pipes and ducts of production, storage, regrind, baling and compacting rooms shall be clean.
b. All production areas, warehouse, toilet, lunch and locker rooms shall be free of evidence of insects, rodents, and birds.
c. Machines and appurtenances shall be kept clean; provided, that minor accumulations of paper, plastic, or metal dust and other production soils incidental to normal fabricating operations do not violate this requirement.
- LOCKER AND LUNCHROOMS
a. Locker and lunchrooms shall be separate from plant operations and be equipped with self-closing doors.
b. Eating and/or storage of food are prohibited in fabricating and storage areas.
c. Locker and lunchrooms shall be kept in a clean and sanitary condition.
d. Cleanable refuse containers, properly labeled, shall be provided, which are covered, impervious, leak-proof, and readily accessible.
e. Proper handwashing facilities shall be convenient to locker and lunchrooms.
f. Signs shall be posted reminding employees to wash their hands before returning to work.
- DISPOSAL OF WASTES
a. All refuse and garbage shall be stored in covered, impervious, and leak-proof containers. This requirement does not pertain to production scrap.
b. All waste containers shall be clearly labeled for their intended purpose and contents.
c. Where possible, garbage and assorted rubbish should be stored outside the building in covered, impervious, cleanable containers. If stored inside the building, it shall be contained in similar receptacles, but in an area separate from fabricating areas.
- PERSONNEL – PRACTICES
a. Hands shall be thoroughly washed before commencing plant functions and as often as may be required to remove soil and contamination, and before returning to work after visiting the toilet room or lunchroom.
b. All personnel shall wear clean outer garments and effective hair restraints.
c. No person affected with any disease in a communicable form, or while a carrier of such disease, and no person with an infected cut or lesion shall work in any processing area in any capacity where there is a likelihood of such person contaminating product or product-contact surfaces with pathogenic organisms (refer to 420-3-16-.10(16).
d. The use of tobacco products is prohibited in fabricating, regrind, and storage areas.
e. Insecured jewelry shall not be permitted in fabricating areas.
- PROTECTION FROM CONTAMINATION
a. All product-contact surfaces of containers, closures, and all materials in process are covered or otherwise protected to prevent the access of insects, dust, condensation, and other contamination.
b. Whenever air under pressure is directed at resin, regrind, colorants, and similar materials or a product-contact surface, it shall be free of oil, dust, rust, excessive moisture, extraneous materials, and odor and shall otherwise comply with the applicable requirements of Appendix H.
c. Air that is directed at product or product-contact surfaces by fans or blowers shall be filtered and shall otherwise comply with the applicable requirements of Appendix H.
d. Only pesticides approved for use in food plants and registered with the EPA shall be used for insect and rodent control.
e. Pesticides shall be used in accordance with the manufacturer's directions and used so as to preclude the contamination of containers or closures.
f. Single-service articles in process shall be protected from contamination by use of a single-service cover sheet or other protective device. This includes chipboard, dividers, separators, bags, and other items that can become contact surfaces.
g. Single-service containers and closures for milk and milk products shall not be fabricated on equipment used for the manufacture of products made of non-food-grade materials, unless such equipment has been thoroughly cleaned and/or purged of all non-food-grade material by a process that will not contaminate the food-grade material.
h. The manufacture of single-service containers and closures for milk and milk products shall be carried on in such a manner that there shall be no cross contamination of raw material or regrind with non-food-grade materials.
i. Equipment and operations are so located within the plant as to prevent overcrowding and allow for cleaning and maintenance procedures.
j. All toxic chemicals, including cleaning and maintenance compounds, shall be adequately segregated from raw materials and finished product.
k. Food containers manufactured by the facility shall not be used for storing miscellaneous items or chemicals.
- STORAGE OF MATERIALS AND FINISHED PRODUCT
a. Blanks, roll stock, and all other single-service containers, closures, and articles shall be kept in a clean, dry place until used, stored, and handled in a sanitary manner; and away from any wall a sufficient distance to facilitate inspection, cleaning, and pest control activities. Any roll stock having dirty or soiled outer turns and/or edges shall have sufficient turns discarded prior to use and the edges trimmed to provide protection from contamination.
b. Appropriate clean, dry storage facilities shall be provided for single-service containers, closures, paper for wrapping, adhesives, blanks, and other production material to provide protection from splash, insects, dust, and other contamination.
c. Where containers and closures are pre-formed in plants other than the original fabricating facility:
(1) Containers, blanks, and closures shall be stored in the original cartons and sealed until used.
(2) Partially used cartons of containers, blanks, and closures shall be re-sealed until used.
d. Containers used for the storage of resin and other raw materials, regrind, broke and trim, intended for use in the process, shall be covered, clean, impervious, and properly identified. Reuse of storage containers such as gaylords is permitted provided single-use plastic liners are used.
e. In-process storage bins that touch the product-contact surface of containers or closures shall be constructed of cleanable, nonabsorbent material and kept clean.
- FABRICATING EQUIPMENT
The requirements of this section pertain to all equipment and processes used in the fabrication of containers and closures, irrespective of the materials used and whether or not mentioned herein. Some of this equipment includes grinders, rollers, reamers and cutters, molders and fittings, extruders, silos, resin bins and hoppers, printing equipment, blanking equipment, and sealing equipment.
a. Rolls, dies, belts, tables, mandrels, transfer tubing, and all other contact surfaces shall be kept clean, sanitary and reasonably free of accumulation of paper, plastic, or metal dust and other production soils. Equipment designed for milk plant use which is utilized for pre-forming containers shall be clean and sanitized prior to operation.
b. Makeshift devices such as tape, rope, twine, paperboards, etc., shall not be used. All fasteners, guides, hangers, supports, and baffles shall be constructed of impervious, cleanable materials and kept in good repair.
c. Take-off tables and other container-contact surfaces shall be constructed of cleanable material, kept clean, and in good repair.
d. All grinders, shredders, and similar equipment used for regrinding shall be installed above the floor or installed in such a manner that they are protected so that floor sweepings and other contaminants cannot enter the grinder or shredder.
e. Storage tanks, silos, gaylords, or bins used for plastic resins shall be so constructed to protect the resin from contamination. All air vents shall be filtered to prevent the entrance of dust, dirt, or insects. Air tubes used to convey resin shall be in good repair and installed in such a manner that protects the resin from contamination. Air tubes used to convey resin shall have end caps attached by a chain or cable that prevents contamination. This item also applies to all raw materials handled in like manner.
- MATERIALS FOR CONSTRUCTION OF CONTAINERS AND CLOSURES
a. Only resin in compliance with 21 CFR Parts 174-178 shall be used for the construction of containers and/or closures.
Only plastic sheeting and extrusions, plastic laminated paper, roll stock, component part(s), molded or formed parts, metal and paperboard blanks, or combinations thereof, from a manufacturing and/or fabricating plant conforming to these standards, shall be used. Fabricating plants listed in the current IMS List shall be considered in compliance with this item.
b. Only food-grade, non-toxic lubricants shall be used on container or closure-contact surfaces. Excess lubricant shall be removed from surfaces close to shafts, rollers, bearing sleeves, and mandrels. These lubricants shall be handled and stored in a manner that shall prevent cross contamination with non-food-grade lubricants. Such storage areas shall be clean and adequately ventilated.
c. Containers, resin, and flashing on the floor, and floor sweepings of production materials and production scrap are prohibited from being reused. This shall not preclude the use of these materials when they comply with a recycling protocol that has been reviewed and accepted by FDA.
- WAXES, ADHESIVES, SEALANTS, COATINGS, AND INKS
a. Waxes, adhesives, sealants, coatings, and inks used for containers and closures shall be handled and stored in a manner that shall prevent cross contamination with similar non-food- grade materials. Such storage areas shall be clean and adequately ventilated.
b. Unused materials shall be covered, labeled, and properly stored.
c. Waxes, adhesives, sealants, coatings, and inks shall not impart odor or taste to the milk or milk products and shall not contaminate the product with microorganisms or toxic or injurious substances. All materials that are applied to the product-contact surface shall comply with the requirements of 21 CFR Parts 174-178.
d. Transfer containers shall be kept clean and shall be properly identified and covered.
e. Waxing shall be performed so as to assure that containers or closures are completely coated and the wax shall be kept at a temperature of 60°C (140°F) or higher.
- HANDLING OF CONTAINERS AND EQUIPMENT
a. Handling container and closure surfaces shall be kept to a minimum.
b. Handlers shall sanitize their hands frequently or wear clean, single-use gloves. Hand sanitizing dispensers, if used, shall be located convenient to all operations involving manual contact.
- WRAPPING AND SHIPPING
a. Blanks, closures, halves, nested or pre-formed containers, and parts such as valves, hoses, tubes, and other fittings shall be properly packaged or containerized prior to shipping.
b. The outer package or containerized units shall protect the contents from dust and other contamination.
c. Transportation vehicles used to ship finished materials from the single-service container or closure plant or within the plant shall be clean and in good repair and shall not have been used for the transportation of garbage, waste, or toxic materials.
d. Paperboard containers, wrappers, and dividers that contact the surface of the container or closure shall not be reused for this purpose.
e. All packaging materials that contact the product-contact surface of the container or closure shall comply with the requirements of 21 CFR Parts 174-178 and the bacteriological standards of Section C of this appendix, but the materials do not have to be manufactured at a listed single-service plant. Some outer packaging material such as corrugated cardboard boxes used for the packaging of milk carton flats are exempt from this bacteriological standard. The edges of these flats are subject to heat during the forming and sealing of the container.
- IDENTIFICATION AND RECORDS
a. Outer wrappings shall be identified with the name and city of the plant where the contents are fabricated, except those manufactured in, and which are only for use in the same facility. Where several plants are operated by one (1) firm, the common firm name may be utilized, provided that the location of the plant at which the contents were fabricated is also shown either directly or by the Federal Information Processing Standards (FIPS) numerical code on the outer wrapper.
b. Single-service glass containers shall be labeled with wording to designate “single-service use only.”
c. Records of all required bacteriological tests of containers and closures shall be maintained at the plant of manufacture for two (2) years and results shall be in compliance with Section C.
d. It is the responsibility of the inspected/certified and listed plant to maintain records verifying the bacterial and chemical safety of all component parts utilized in the final assembled product.
e. The fabricating plant shall have on file information from suppliers of raw material, waxes, adhesives, sealants, coatings, and inks indicating that the material complies with the requirements of 21 CFR Parts 174-178.
f. The fabricating plant shall have on file information from the suppliers of packaging materials specified in Section 19e of these Standards indicating that the material complies with the requirements of 21 CFR Parts 174-178 and the bacteriological standards of Section C. There are no specifications for sampling frequency. The Health Officer may choose to collect samples of packaging materials to determine compliance with bacteriological standards of this section.
g. Multi-plant corporations may have all the required information at a central location as long as it can be transmitted to the site upon request.
- SURROUNDINGS
a. Exterior surroundings shall be neat and clean and free from conditions that might attract or harbor flies, other insects, and rodents.
b. Driveways, lanes, and areas serving the plant vehicular traffic are graded, drained, and free from pools of standing water.
E. CRITERIA FOR LISTING CERTIFIED SINGLE-SERVICE MANUFACTURERS ON THE IMS LIST
The following criteria have been developed to allow the Health Officer’s flexibility in evaluating and listing single-service manufacturing plants. The Health Officer may choose from the following list of criteria for listing certified single-service manufacturers:
-
Single-service manufacturers that operate in conjunction with an IMS Listed milk plant may be listed for twenty-four (24) months if the single-service plant is inspected at least quarterly using the ADPH-FML-229 Form (Alabama Department of Public Health Manufacturing Plant Inspection Report Single-Service Containers) and records of such inspections and all required tests are maintained by the Health Officer; provided that, single-service manufacturers that operate in conjunction with an IMS HACCP listed milk plant may be listed for twenty-four (24) months if the single-service plant is integrated into the milk plant’s NCIMS HACCP system and if the single-service plant is inspected at the minimum milk plant audit frequency specified in Appendix K, using the ADPH-FML-229 Form (Alabama Department of Public Health Manufacturing Plant Inspection Report Single-Service Containers) and records of such inspections and all required tests are maintained by the Health Officer. The permit for the milk plant shall also include the inspection of the single-service manufacturing areas.
-
Single-service manufacturers that operate in conjunction with an IMS listed milk plant and are not inspected at least quarterly and/or are not included under a permit system may be optionally listed for twelve (12) months.
-
Single-service manufacturers that operate as a separate entity may be listed for twenty-four (24) months if the Health Officer has a permit system and inspects the plant using the ADPH-FML-229 Form (Alabama Department of Public Health Manufacturing Plant Inspection Report Single-Service Containers) at least quarterly. All testing of containers and individual water supplies shall be under the direction of the Health Officer and kept on file.
-
Single-service manufacturers that operate as a separate entity and are not inspected by the Health Officer at least quarterly and/or do not have a permit system may be optionally listed for twelve (12) months.
-
Certification of single-service manufacturing plants may be valid for a period not to exceed one (1) or two (2) years from the earliest survey date, based on the criteria above. The expiration date is one (1) or two (2) years from the earliest survey date. In the case of a one (1) year certification with the earliest survey date of June 15, 2013, the expiration date would be June 14, 2014.
The following procedures shall be followed for listing certified single-service manufacturers on the IMS List:
-
For domestic firms: triplicate copies or USPHS/FDA’s electronic version (transmitted via computer) of FORM FDA 2359d-REPORT OF CERTIFICATION (Fabrication of Single-Service Containers and Closures for Milk and Milk Products) shall be submitted by the SRO to the appropriate Regional Office of the USPHS/FDA for single-service manufacturers who desire to be listed on the IMS List.
-
For foreign firms: duplicate copies or USUSPHS/FDA’s electronic version (transmitted via computer) of FORM FDA 2359d-REPORT OF CERTIFICATION (Fabrication of Single-Service Containers and Closures for Milk and Milk Products) shall be submitted by the TPC or private consultant conducting the certification to CFSAN’s Milk Safety Team (HFS-316), Food and Drug Administration, 5100 Paint Branch Parkway, College Park, MD 20740-3835 for single-service manufacturers who desire to be listed on the IMS List.
-
The Certified Single-Service Manufacturer is not listed on the IMS List unless the “PERMISSION TO PUBLISH” SECTION of FORM FDA 2359d is signed by an officer of the firm authorizing the release.
a. For the submission of USPHS/FDA’s electronic version, a signed copy of FORM FDA 2359d, including Section 12, shall be maintained on file by the Rating Agency and shall be reviewed as part of the Single-Service Listing Audit and/or the Regulatory/Rating Agency Program Evaluation.
b. For the submission of USPHS/FDA’s electronic version, a signed copy of FORM FDA 2359d, including Section 12, shall be maintained on file by the private consulting firm.
- The Certified Single-Service Manufacturer may be listed on the IMS List as a "PARTIAL" listing. A "PARTIAL" listing shall mean that only specific production rooms or fabrication lines or machines have been evaluated in regard to specific containers or closures or specific size of containers or closures and conform to the specifications contained within Appendix J.
History
- Author: G. M. Gallaspy, Jr.
- Authority: Code of Ala. 1975, §§22-2-2, 22-20-7.
- Repealed and New Rule: Filed October 18, 2018; effective December 2, 2018.
Ala. Admin. Code r. 420-3-16-AK Appendix K - HACCP Program
I. THE HACCP SYSTEM INTRODUCTION
HISTORY OF HACCP - The use of the HACCP System is not new to the dairy industry. HACCP is a logical, simple, effective, but highly structured system of food safety control.
The HACCP System was introduced to the food industry as a spin-off of the space program during the 1960s. The National Aeronautics and Space Administration (NASA) used HACCP to provide assurance of the highest quality available for components of space vehicles. This program to develop assurance of product reliability was carried over into the development of foods for astronauts.
The U.S. Army Natick Laboratories, in conjunction with NASA, began to develop the foods needed for manned space exploration. They contracted with the Pillsbury Company to design and produce the first foods used in space. While Pillsbury struggled with certain problems, such as how to keep food from crumbling in zero gravity, they also undertook the task to come as close as possible to 100 percent assurance that the foods they produced would be free of bacterial or viral pathogens.
Using traditional quality control methods for the food industry was soon proven to be unworkable for the task Pillsbury had undertaken. The degree of safety desired was not provided by the current programs, and the product sampling necessary to provide an adequate degree of safety would have been prohibitive to commercialization of space foods. Pillsbury discarded its standard quality control methods and began an extensive evaluation, in conjunction with NASA and Natick Labs, to evaluate food safety. They soon realized that to be successful they would have to have control over their process, raw materials, environment, and their people. In 1971, they introduced HACCP as a preventive system that enables manufacturers to produce foods with a high degree of assurance that the foods were produced safely.
BACKGROUND - HACCP is a management tool that provides a structured and scientific approach to the control of identified hazards. HACCP is a logical basis for better decision-making with respect to product safety. HACCP has international recognition as an effective means of controlling food safety hazards and is endorsed as such by the joint Food and Agriculture Organization (FAO) of the World Health Organization (WHO) Codex Alimentarius Commission. The U.S. National Advisory Committee on Microbiological Criteria for Foods (NACMCF) has also endorsed it.
The HACCP concept will enable those operating and regulating under a HACCP Plan to move to a preventive approach, whereby potential hazards are identified and controlled in the manufacturing environment, i.e., prevention of product failure. HACCP allows for a preventive, systematic approach to food safety.
VOLUNTARY PARTICIPATION - This Appendix describes a NCIMS voluntary HACCP Program alternative to the traditional inspection system. A milk plant, receiving station, or transfer station may not participate in the NCIMS voluntary HACCP Program unless the Health Officer’s responsible for the oversight of the facility agrees to participate with the milk plant(s), receiving station(s), and transfer station(s) in the NCIMS voluntary HACCP Program. Both parties shall provide written commitment to each other that the necessary resources to support participation in the NCIMS voluntary HACCP Program shall be made available.
Management responsible for both the Health Officer and the milk plant, receiving station, and/or transfer station shall be willing to provide the resources required to develop and implement a successful HACCP System.
HACCP PRINCIPLES - Following are the seven (7) HACCP principles to be included in a HACCP Plan:
-
Conduct a hazard analysis.
-
Determine the critical control points.
-
Establish critical limits.
-
Establish monitoring procedures.
-
Establish corrective actions.
-
Establish verification procedures.
-
Establish record-keeping and documentation procedures.
PREREQUISITE PROGRAMS (PPs) - Prior to the implementation of a HACCP Plan, there is a requirement for milk plants, receiving stations, and transfer stations to develop, document and implement written PPs. PPs provide the basic environment and operating conditions that are necessary for the production of safe, wholesome food. Many of the conditions and practices are specified in federal and state regulations and guidelines.
PPs and the HACCP System in total, address public health concerns such as those identified in 21 CFR Part 7, Recalls; Part 110, Good Manufacturing Practices (GMPs); Part 113, Thermally Processed Low-Acid Foods Packaged in Hermetically Sealed Containers; Part 131, Milk and Cream; the Grade “A” PMO; and the current edition of the NACMCF HACCP Principles and Application Guidelines.
SUMMARY - The seven (7) principles of HACCP are also called the HACCP Plan. When combined with the PPs, they constitute a HACCP System. The NCIMS voluntary HACCP Program described in this Appendix includes the HACCP System and other prescribed Grade “A” PMO criteria, such as drug residue testing and trace back; use of milk only from supplies that have been awarded a milk sanitation compliance rating of 90 percent or better or from an acceptable IMS HACCP listed source; and the labeling requirements of Section 4. When properly implemented, the NCIMS voluntary HACCP Program described in this appendix will provide assurance of milk and milk product safety that is equivalent to that provided under the traditional inspection system.
II. IMPLEMENTATION OF A HACCP SYSTEM
PRELIMINARY STEPS - Preliminary steps as listed in the NACMCF document should be followed when producing a HACCP Plan. Complete, up-to-date process flow diagrams are required for all milk and milk products manufactured. Flow diagrams may be combined when processes, products, and hazards are similar.
PREREQUISITE PROGRAM - HACCP is not a stand-alone program, but is part of a larger control system. PPs are the universal procedures used to control the conditions of the milk plant environment that contribute to the overall safety of the milk or milk product. They represent the sum of programs, practices, and procedures that shall be applied to produce and distribute safe milk and milk products in a clean, sanitary environment. They differ from CCPs in that they are basic sanitation programs that reduce the potential occurrence of a milk or milk product safety hazard. Frequently, both HACCP Plan CCPs and PPs control measures are necessary to control a food safety hazard.
HACCP may be implemented only in a facility that is constructed and operated to provide a sanitary environment. Milk plant, receiving station, or transfer station premises, building construction, maintenance, and housekeeping shall be maintained in a manner sufficient to provide such an environment. These factors shall be controlled by effective milk plant, receiving station, or transfer station programs or by PPs, as the milk plant, receiving station, or transfer station chooses.
The exact set of PPs will vary since their application is milk or milk product and process specific. The existence and effectiveness of PPs should be assessed during the design and implementation of each HACCP Plan. PPs should be documented and regularly audited. An audit review consists of verifying that the company has a program implemented that indicates how the company monitors and controls each of the PPs. PPs are established and managed separately from the HACCP Plan.
- Required PPs - The following required PPs shall have a brief written description or checklist that the PPs can be audited against to ensure compliance. PPs shall include procedures that can be monitored; records that specify what is monitored; and how often it will be monitored.
Each milk plant, receiving station, or transfer station shall have and implement PPs that address conditions and practices before, during, and after processing. The PPs shall address:
a. Safety of the water that comes into contact with milk or milk products or product-contact surfaces, including steam and ice.
b. Condition and cleanliness of equipment product-contact surface.
c. Prevention of cross-contamination from insanitary objects and/or practices to milk or milk products or product-contact surfaces, packaging material and other food-contact surfaces, including utensils, gloves, outer garments, etc., and from raw product to processed product.
d. Maintenance of handwashing, hand sanitizing, and toilet facilities.
e. Protection of milk or milk product, packaging material, and product-contact surfaces from adulteration with lubricants, fuel, pesticides, cleaning compounds, sanitizing agents, condensate and other chemical, physical, and biological contaminants.
f. Proper labeling, storage, and use of toxic compounds.
g. Control of employee health conditions, including employee exposure to high risk situations that could result in the microbiological contamination of milk or milk products, packaging materials, and product-contact surfaces.
h. Pest exclusion from the milk plant.
In addition to the required PPs specified above, any other PPs that are being relied upon in the hazard analysis to reduce the likelihood of hazards such that they are not reasonably likely to occur, shall also be monitored, audited, and documented as required PPs.
-
Monitoring and Correction - The milk plant, receiving station, or transfer station shall monitor the conditions and practices of all required PPs with sufficient frequency to ensure conformance with those conditions and that are appropriate both to the milk plant, receiving station, or transfer station and to the safety of the milk or milk product being processed. Each milk plant, receiving station, or transfer station shall document the correction of those conditions and practices that are not in conformance. Devices such as indicating and recording thermometers that are used to monitor PPs shall be calibrated to assure accuracy at a frequency determined by the milk plant, receiving station, or transfer station.
-
Required Records - Each milk plant, receiving station, or transfer station shall maintain records that document the monitoring and corrections required by this appendix. These records are subject to the record keeping requirements of this appendix.
HAZARD ANALYSIS - Each milk plant, receiving station, or transfer station shall develop, or have developed for it, a written hazard analysis to determine whether there are milk or milk product hazards that are reasonably likely to occur for each type of milk or milk product processed or handled by the milk plant, receiving station, or transfer station and to identify the control measures that the milk plant, receiving station, or transfer station can apply to control those hazards.
The hazard analysis shall include hazards that can be introduced both within and outside the milk plant, receiving station, or transfer station environment, including hazards that can occur during handling, transportation, processing, and distribution.
A hazard that is reasonably likely to occur is one for which a prudent milk plant, receiving station, or transfer station operator would establish controls because experience, illness data, scientific reports, or other information provide a basis to conclude that there is a reasonable possibility that, in the absence of these controls, the hazard will occur in the particular type of milk or milk product being processed. The hazard analysis shall be developed by an individual(s) trained in accordance with this appendix and shall be subject to the record keeping requirements as described in this appendix.
- In evaluating what milk or milk product hazards are reasonably likely to occur, at a minimum, consideration should be given to the following:
a. Microbiological contamination.
b. Parasites.
c. Chemical contamination.
d. Unlawful drug and pesticide residues.
e. Natural toxins.
f. Unapproved use of food or color additives.
g. Presence of undeclared ingredients that may be allergens.
h. Physical hazards.
- Milk plant, receiving station, or transfer station operators should evaluate product ingredients, processing procedures, packaging, storage, and intended use; facility and equipment function and design; and milk plant sanitation, including employee hygiene, to determine the potential effect of each on the safety of the finished milk or milk product for the intended consumer.
HACCP PLAN
-
Every milk plant, receiving station, or transfer station shall have and implement a written HACCP Plan whenever a hazard analysis reveals one (1) or more hazards that are reasonably likely to occur. The HACCP Plan shall be developed by an individual(s) who has been trained and shall be subject to record keeping requirements in accordance with this appendix. A HACCP Plan shall be specific to each location and milk or milk product. The plan may group similar types of milk and milk products together, or similar types of production methods together, if the hazards, CCPs, CLs, and procedures required to be identified and performed by 2 of this section are essentially identical, provided that any required features of the plan that are unique to a specific milk or milk product or method are clearly delineated in the plan and are observed in practice.
-
Contents of the HACCP Plan - The HACCP Plan shall, at a minimum:
a. Include complete up-to-date process flow diagrams for all milk and milk products manufactured. Flow diagrams may be combined when processes, milk and milk products, and hazards are similar.
b. List all hazards that are reasonably likely to occur as identified in the hazard analysis specified above, and that shall be controlled for each type of milk or milk product.
c. List the CCPs for each of the identified hazards, including the appropriate:
(1) CCPs designed to control hazards that could occur or could be introduced in the milk plant, receiving station, or transfer station environment.
(2) CCPs designed to control hazards introduced outside the milk plant, receiving station, or transfer station environment, including hazards that occur before arriving at the milk plant, receiving station, and/or transfer station.
(3) List the CLs that shall be met at each of the CCPs.
d. List the procedures and the frequency with which they are to be performed that will be used to monitor each of the CCPs to ensure compliance with the CLs.
e. Include any corrective action plans that have been developed in accordance with the corrective action requirements as described in this Appendix, and that are to be followed in response to deviations from CLs at CCPs.
f. List the verification and validation procedures, and the frequency with which they are to be performed, that the milk plant, receiving station, or transfer station will use in accordance with verification and validation requirements as described in this appendix.
g. Provide a record keeping system that documents the monitoring of the CCPs in accordance with the record requirements as described in this appendix. The records shall contain the actual values and observations obtained during monitoring.
- Sanitation - Sanitation controls may be included in the HACCP Plan. However, to the extent that they are monitored in accordance with the PPs, they need not be included in the HACCP Plan.
CORRECTIVE ACTIONS - Whenever a deviation from a CL occurs, a milk plant, receiving station, or transfer station shall take corrective action by following the procedures set forth in 1 or 2 of this section.
a. Milk plants, receiving stations, or transfer stations may develop written corrective action plans which become a part of their HACCP Plan(s) in accordance with this appendix. These corrective action plans may predetermine the corrective actions that milk plants, receiving stations, and transfer stations will take whenever there is a deviation from a CL. A corrective action plan that is appropriate for a particular deviation is one (1) that describes the steps to be taken and assigns responsibility for taking those steps, to ensure that:
b. No milk or milk product is allowed to enter commerce that is either injurious to health or is otherwise adulterated as a result of the deviation; or
c. If such milk or milk product has entered commerce, it is expeditiously removed; and
d. The cause of the deviation is corrected.
- When a deviation from a CL occurs, and the milk plant, receiving station, or transfer station does not have a corrective action plan that is appropriate for that deviation, the milk plant, receiving station, or transfer station shall:
a. Segregate and hold the affected milk or milk product, at least until the requirements of paragraphs 2.b and 2.c of this section are met.
b. Perform or obtain a review to determine the acceptability of the affected milk or milk product for distribution. The review shall be performed by an individual or individuals qualified by training or experience to perform such a review.
c. Take corrective action, when necessary, with respect to the affected milk or milk product to ensure that no milk or milk product is allowed to enter commerce that is either injurious to health or is otherwise adulterated as a result of the deviation.
d. Take corrective action, when necessary, to correct the cause of the deviation.
e. Perform or obtain timely validation by a qualified individual(s), as required in this appendix, to determine whether modification of the HACCP Plan is required to reduce the risk of recurrence of the deviation, and modify the HACCP Plan as necessary.
- All corrective actions taken in accordance with this section shall be fully documented in records that are subject to verification.
VERIFICATION AND VALIDATION
- Every milk plant, receiving station, or transfer station shall verify that the HACCP System is being implemented according to design, except that the milk plant’s APPS or RPPS, respectively, as defined by these rules, shall be managed separately from the NCIMS HACCP System, even if identified as a CCP in the hazard analysis. The milk plant's APPS or RPPS, respectively, shall be inspected by the FDA, or the state regulatory agency when designated by the FDA, in accordance with the applicable requirements of 21 CFR Parts 108, 110, and 113 at a frequency determined by FDA.
a. Verification activities shall include:
(1) The calibration of CCP process-monitoring instruments, i.e., pasteurization tests, etc.
(2) At the option of the milk plant, receiving station, or transfer station the performance of periodic end-product or in-process testing.
(3) A review, including signing and dating by an individual who has been trained in accordance with the training requirements of this appendix, of the records that document.
(i) The Monitoring of CCPs - The purpose of this review shall be, at a minimum, to ensure that the records are complete and to verify that the recorded document values are within the CLs. This review shall occur at a frequency that is appropriate to the importance of the record and as specified in the HACCP Plan.
(ii) The Taking of Corrective Action - The purpose of this review shall be, at a minimum, to ensure that the records are complete and to verify that appropriate corrective action(s) was taken in accordance with the corrective action requirements cited before. This review shall occur at a frequency that is appropriate to the importance of the record. A centralized deviation log is required.
(iii) The calibrating of any process monitoring instruments used at CCPs and the performance of any periodic end-product or in-process testing that is part of the milk plant, receiving station, or transfer station's verification activities.
The purpose of these reviews shall be, at a minimum, to ensure that the records are complete and that these activities occurred in accordance with the milk plants, receiving stations, or transfer stations written procedures. These reviews shall occur within a reasonable time after the records are made.
- The taking of corrective action procedures whenever any verification procedure establishes the need to take a corrective action.
b. The calibration of CCP process-monitoring instruments, and the performance of any periodic end-product and in-process testing, in accordance with 1.a.(3)ii) and 1.a.(3)iii) of this section, shall be documented in records that are subject to the record keeping requirements in this appendix.
- Validation of the HACCP Plan - Every milk plant, receiving station, or transfer station shall validate that the HACCP Plan is adequate to control hazards that are reasonably likely to occur. This validation shall occur at least once within twelve (12) months after implementation and at least annually thereafter or whenever any changes in the process occur that could affect the hazard analysis or alter the HACCP Plan. Such changes may include changes in the following:
a. Raw materials or source of raw materials; product formulation; processing methods or systems, including computers and their software; packaging; finished product distribution systems; or the intended use or intended consumers of the finished product and consumer complaints.
The validation shall be performed by a qualified individual(s) trained in accordance with the requirements described in this appendix and shall be subject to the record keeping requirements cited below. The HACCP Plan shall be modified immediately whenever a validation reveals that the plan is no longer adequate to fully meet the requirements of this document.
- Validation of the Hazard Analysis - Whenever a milk plant, receiving station, or transfer station does not have a HACCP Plan, because a hazard analysis has revealed no hazards that are reasonably likely to occur, the milk plant, receiving station or transfer station shall reassess the adequacy of the hazard analysis whenever there are any changes in the process that could reasonably affect whether a hazard exists. Such changes may include changes in the following:
a. Raw materials or source of raw materials.
b. Product formulation.
c. Processing methods or systems, including computers and their software.
d. Packaging.
e. Finished product distribution systems; or
f. The intended use or intended consumers of the finished product.
g. Consumer complaints.
A qualified individual(s) trained in accordance with the training requirements of this appendix shall perform the validation.
RECORDS
- Required Records - It is essential that milk plants, receiving stations, and transfer stations use consistent terminology to identify each piece of equipment, record, document, or other program throughout their written HACCP System. A milk plant, receiving station, or transfer station shall maintain the following records documenting the milk plant, receiving station, or transfer station's HACCP System:
a. Records documenting the ongoing application of the PP, including a brief written description, monitoring, and correction records.
b. The written hazard analysis.
c. The written HACCP Plan.
d. Required HACCP documents and forms specified in 1a-c. of this section shall be dated or identified with a version number. Each page shall be marked with a new date or version number whenever that page is updated.
e. A Table of Contents and centralized list of the HACCP program records, by title, documenting the ongoing application of the HACCP System shall be maintained and provided for review.
f. A document change log.
g. Records documenting the ongoing application of the HACCP Plan that include:
(1) Monitoring of CCPs and their CLs, including the recording of actual times, temperatures, or other measurements as prescribed in the milk plant’s, receiving station’s, or transfer station’s HACCP Plan.
(2) Corrective actions, including all actions taken in response to a deviation.
(3) A centralized deviation log is required.
(4) Plan validation dates.
h. Records documenting verification and validation of the HACCP System, including the HACCP Plan, hazard analysis, and PPs.
- General Requirements - Records required by this section shall include:
a. The identity and location of the milk plant, receiving station, or transfer station.
b. The date and time of the activity that the record reflects.
c. The signature or initials of the person(s) performing the operation or creating the record.
d. Where appropriate, the identity of the milk or milk product and the production code, if any. Processing and other information shall be entered on records at the time that it is observed. The records shall contain the actual values and observations obtained during monitoring.
- Documentation
a. The records in paragraphs 1a-c. of this section shall be signed and dated by the most responsible individual onsite at the milk plant, receiving station, or transfer station. This signature shall signify that these records have been accepted by the firm.
b. The records in paragraphs 1a-c. of this section shall be signed and dated:
(1) Upon initial acceptance.
(2) Upon any modification.
(3) Upon verification and validation in accordance with the requirements cited above.
- Record Retention
a. All records required by this section shall be retained at the milk plant, receiving station, or transfer station for perishable or refrigerated products for at least one (1) year after the date that such products were prepared, and in the case of frozen, preserved, or shelf-stable products, for two (2) years after the date that the products were prepared or the shelf-life of the product, whichever is greater, unless longer retention time is required by other regulations.
b. Records that relate to the adequacy of equipment or processes used, such as commissioning or process validation records, including the results of scientific studies and evaluations, shall be retained at the milk plant, receiving station, or transfer station facility for at least two (2) years after the date that the milk plant, receiving station, or transfer station last used such equipment or process.
c. Off-site storage of processing records is permitted after six (6) months following the date that the monitoring occurred, if such records can be retrieved and provided on-site within twenty-four (24) hours of a request for official review. Electronic records are considered to be on-site if they are accessible from an on-site location.
d. If the processing facility is closed for a prolonged period, the records may be transferred to some other reasonably accessible location(s) but shall be immediately returned to the processing facility for official review upon request.
-
Official Review - All records required by this section shall be available for official review at reasonable times.
-
Records Maintained on Computers - The maintenance of records on computers, in accordance with the requirements cited above, is acceptable.
III. EMPLOYEE EDUCATION AND TRAINING
The success of a HACCP System depends on educating and training management and employees in the importance for their role in producing safe milk and milk products. This should also include information in the control of milk borne hazards related to all stages of dairy production and processing. Specific training activities should include working instructions and procedures that outline the tasks of employees monitoring specific CCPs and PPs.
IV. TRAINING AND STANDARDIZATION
HACCP training for industry and regulatory personnel will be based on the current “Hazard Analysis and Critical Control Point Principles and Application Guidelines” of NACMCF, the current FDA HACCP recommendations, and the regulatory requirements of this appendix and related sections of these rules.
The Health Officer personnel responsible for the evaluation, licensing, and regulatory audits of facilities using the NCIMS voluntary HACCP Program shall have equivalent training to the training required to perform traditional NCIMS functions. They shall also have specialized training in conducting HACCP System audits.
Industry, regulatory, rating, and FDA personnel should be trained together.
HACCP TRAINING
- Core Curriculum - The Dairy HACCP Core Curriculum consists of:
a. Basic HACCP training.
b. An orientation to the requirements of the NCIMS voluntary HACCP Program.
Basic HACCP training consists of instruction in the application of the NACMCF Principles of HACCP to Food Safety. This training includes practical exercises in conducting a hazard analysis and evaluating potential hazards; in writing a HACCP Plan; and in the validation of the plan. It should be taught by experienced instructors.
The orientation component ideally is coupled with the basic HACCP training but can be taught separately. The content of the orientation will be conducted under the guidance of the NCIMS. It is intended to familiarize industry and regulatory personnel with specific dairy HACCP concerns and the regulatory requirements under the NCIMS voluntary HACCP Program. It is to be taught by instructors experienced in the application of HACCP under the NCIMS voluntary HACCP Program.
The industry individual(s) performing the functions identified in this Appendix requiring training or listed in Part 2 of this section shall have successfully completed appropriate training in the application of HACCP principles to milk and milk product processing at least equivalent to that received under the Dairy HACCP Core Curriculum. Alternatively, job experience may qualify an individual to perform these functions if the experience has provided knowledge at least equivalent to that provided through the standardized curriculum.
- Industry Personnel - Only industry individuals who have met the requirements of Part 1 of this section shall be responsible for the following functions:
a. Developing PPs.
b. Developing the hazard analysis, including delineating control measures, as required.
c. Developing a HACCP Plan that is appropriate for the specific milk plant, receiving station, or transfer station, in order to meet these requirements.
d. Validating and modifying the HACCP Plan in accordance with the corrective action procedures and the validation activities as specified.
e. Performing required HACCP Plan records reviews.
- Regulatory Personnel - Regulatory personnel performing HACCP audits shall have successfully completed appropriate training in the application of HACCP principles for milk and milk product processing at least equivalent to that received under the Dairy HACCP Core Curriculum.
V. HACCP AUDITS AND FOLLOW-UP ACTIONS
REGULATORY AGENCY AUDITS, ENFORCEMENT AUDITS, ACTIONS AND FOLLOW-UP - Audits shall be conducted of the milk plant, receiving station, or transfer station facility, and the NCIMS voluntary HACCP Program to ensure compliance with the HACCP System and other associated NCIMS regulatory requirements.
The audit may be announced at the discretion of the auditor under certain circumstances, i.e., initial audit, follow-up audit, new construction, pasteurizer checks, etc. When unannounced audits are conducted, the audits shall not be completed until appropriate milk plant personnel have had an opportunity to make all pertinent records available for review by the auditor.
AUDITING PROCEDURES
- Pre-Audit Management Interview - Review and discuss the milk plant HACCP System including:
a. Changes in the management structure.
b. The Hazard Analysis - Ensure that all milk and/or milk product hazards are addressed.
c. Changes in the HACCP Plan.
d. Changes in the PPs.
e. Changes in the flow diagram.
f. Changes in milk or milk products or processes.
-
Review past Audit Reports (AR) and corrections of deficiencies and non-conformities, if any.
-
In-milk plant review of the implementation and verification of the HACCP System.
-
Review records of the HACCP System.
-
Review compliance with other applicable NCIMS regulatory requirements*.
-
Discuss findings and observations.
-
Prepare and issue an AR based on findings of deficiencies and non-conformities. The AR shall include timelines for the correction of all identified deficiencies and non-conformities.
-
Conduct the exit interview.
Note: Examples of Other Applicable NCIMS Requirements:
-
Raw Milk Supply Source.
-
Labeling Compliance.
-
Adulteration.
-
Licensing Requirements.
-
Drug Residue Testing and Trace Back Requirements.
-
Regulatory Samples in Compliance.
-
Approved Laboratory Utilized for the Required Regulatory Tests.
-
Pasteurization Equipment Design and Installation.
THE HEALTH OFFICER ENFORCEMENT ACTION/FOLLOW-UP
The Health Officer shall:
-
Prepare and issue ARs based on findings of deficiencies and non-conformities and other NCIMS requirements.
-
Review the AR with the milk plant and establish time lines for the correction of all identified deficiencies and non-conformities and other NCIMS requirements.
-
Follow-up to ensure corrections are made as a result of the issuance of the AR.
-
Take immediate action when an imminent health hazard is observed to prevent further movement of milk and milk products until such hazards have been eliminated.
-
Initiate regulatory enforcement action such as permit suspension, revocation, hearings, court actions, and/or other equivalent measures when the milk plant, receiving station, or transfer station has failed to recognize or correct a deficiency(ies) or nonconformity(ies).
AUDIT TIMEFRAMES
| Audits | Frequency Minimums | | --- | --- | | First Year after Initial Regulatory Audit | Initial audit; next audit in thirty (30) to forty-five (45) days; and four (4) month intervals thereafter, unless the Health Officer determines that a greater frequency is warranted. | | Subsequent Audits | Every six (6) months unless the Health Officer determines that a greater frequency is warranted*. | | Compliance Follow-Ups | Compliance follow-ups shall be made as frequently as necessary to assure that problems observed by the Health Officer have been resolved. |
*The Health Officer may elect to extend the minimum audit frequency from four (4) to six (6) months as long as the following conditions exist:
-
Item 12b on FORM FDA 2359m-MILK PLANT, RECEIVING STATION, OR TRANSFER STATION NCIMS HACCP SYSTEM AUDIT REPORT is not marked on the regulatory audit for the current HACCP audit.
-
No current two (2) out of four (4) warning letter(s) or three (3) out of five (5) violation letter(s) for finished milk and/or milk product, or violative water sample results.
-
No CLEs on the current or prior audit.
Audit Report Form (refer to Appendix M).
History
- Author: G. M. Gallaspy, Jr.
- Authority: Code of Ala. 1975, §§22-2-2, 22-20-7.
- Repealed and New Rule: Filed October 18, 2018; effective December 2, 2018.
Ala. Admin. Code r. 420-3-16-AL Appendix L - Applicable Regulations, Standards of Identity for Milk and Milk Products, the Federal Food, Drug, and Cosmetic Act, and the Federal Insecticide, Fungicide and Rodenticide Act
| REGULATION/ STANDARD | TITLE | | --- | --- | | 7 CFR 58.334 | Pasteurization | | 7 CFR 58.2601 | Whey | | 21 CFR PART 7 | Enforcement Policy | | 21 CFR PART 11 | Electronic Records; Electronic Signature | | 21 CFR PART 101 | Food Labeling | | 21 CFR PART 108 | Emergency Permit Control | | 21 CFR PART 110 | Current Good Manufacturing Practice In Manufacturing, Packing, or Holding Human Food | | 21 CFR PART 113 | Thermally Processed Low-Acid Foods Packaged In Hermetically Sealed Containers | | 21 CFR PART 114 | Acidified Foods | | 21 CFR 130.10 | Requirements for Foods Named by Use of A Nutrient Content Claim and A Standardized Term | | 21 CFR 131.110 | Milk | | 21 CFR 131.111 | Acidified Milk | | 21 CFR 131.112 | Cultured Milk | | 21 CFR 131.115 | Concentrated Milk | | 21 CFR 131.120 | Sweetened Condensed Milk | | 21 CFR 131.123 | Lowfat Dry Milk | | 21 CFR 131.125 | Nonfat Dry Milk | | 21 CFR 131.127 | Nonfat Dry Milk Fortified With Vitamins A and D | | 21 CFR 131.147 | Dry Whole Milk | | 21 CFR 131.149 | Dry Cream | | 21 CFR 131.150 | Heavy Cream | | 21 CFR 131.155 | Light Cream | | 21 CFR 131.157 | Light Whipping Cream | | 21 CFR 131.160 | Sour Cream | | 21 CFR 131.162 | Acidified Sour Cream | | 21 CFR 131.170 | Eggnog | | 21 CFR 131.180 | Half-and-Half | | 21 CFR 131.200 | Yogurt | | 21 CFR 131.203 | Lowfat Yogurt | | 21 CFR 131.206 | Nonfat Yogurt | | 21 CFR 133.128 | Cottage Cheese | | 21 CFR 133.129 | Dry Curd Cottage Cheese | | 21 CFR 173.310 | Boiler Water Additives | | 21 CFR 174 | Indirect Food Additives-General | | 21 CFR PART 175 | Indirect Food Additives: Adhesives and Components of Coatings | | 21 CFR PART 176 | Indirect Food Additives: Paper and Paperboard Components | | 21 CFR PART 177 | Indirect Food Additives: Polymers | | 21 CFR PART 178 | Indirect Food Additives: Adjuvants, Production Aids, and Sanitizers | | 21 CFR 182.6285 | Dipotassium Phosphate | | 21 CFR 184.1666 | Propylene Glycol | | 21 CFR 184.1979 | Whey | | 21 CFR 184.1979(2) | Concentrated Whey | | 21 CFR 184.1979(3) | Dried or Dry Whey | | 21 CFR 184.1979a | Reduced Lactose Whey | | 21 CFR 184.1979b | Reduced Minerals Whey | | 21 CFR 184.1979c | Whey Protein Concentrate | | 21 CFR 1240.61 | Mandatory Pasteurization for All Milk and Milk Products in Final Package Form Intended for Direct Human Consumption | | 40 CFR PART 141 | National Primary Drinking Water Regulations | | 40 CFR 152.500 | Requirements for Devices | | 40 CFR 156.10 | Labeling Requirements for Devices and Their Products | | 40 CFR 158 | Data Requirements for Registration, Pesticide Assessment Guidelines | | 40 CFR 180.940 | Tolerance Exemptions for Active and Inert Ingredients for Use in Antimicrobial Formulations (Food-Contact Surface Sanitizing Solutions) |
FFD & CA, as amended, Sec. 402. [342] Adulterated Food and Sec. 403. [343] Misbranded Food
History
- Author: G. M. Gallaspy, Jr.
- Authority: Code of Ala. 1975, §22-2-2, §22-20-7.
- Repealed and New Rule: Filed October 18, 2018; effective December 2, 2018.
Ala. Admin. Code r. 420-3-16-AM Appendix M - Reports and Records
The following forms are available at www.alabamapublichealth.gov.
ADPH-FML 201/Revised 2016 Application for Permit for Operation of a Grade A or Manufacturing Milk Dairy Farm ADPH-FML 201a-Revision 8/1/17 Application for Permit for Processing, Handling, Manufacturing, or Distribution of Milk, Milk Products, Frozen Desserts or Single-Service Containers and/or Closures ADPH-FML-INSP.204/Rev. 6-91 Milk Plant and/or Frozen Dessert Plant Inspection Report ADPH-FML-203.03.13.ch Dairy Farm Inspection Report ADPH-FML-229.03.13.ch Manufacturing Plant Inspection Report ADPH-FML-216.03.13.ch Milk Plant Equipment Tests Report ADPH-FML-229.0.14.ch Milk Sample Collector Evaluation Report ADPH-FML-248A.03.13.ch Bulk Milk Hauler Report and Sampler Evaluation Form
http://www.fda.gov/aboutFDA/reportsmanualsforms/forms/default.htm .
FORM FDA 2359 MILK PLANT INSPECTION REPORT FORM FDA 2359a DAIRY FARM INSPECTION REPORT FORM FDA 2359b MILK PLANT EQUIPMENT TEST REPORT FORM FDA 2359c MANUFACTURING PLANT INSPECTION REPORT (Single- Service Milk Containers and Closures) FORM FDA 2359d REPORT OF CERTIFICATION (Fabrication of Single- Service Containers and Closures for Milk and Milk Products) FORM FDA 2359m MILK PLANT, RECEIVING STATION, OR TRANSFER STATION NCIMS HACCP SYSTEM AUDIT REPORT FORM FORM FDA 2399 MILK SAMPLE COLLECTOR EVALUATION REPORT (Dairy Plant Sampling – Raw and Pasteurized Milk) FORM FDA 2399a BULK MILK HAULER/SAMPLER EVALUATION REPORT FORM FDA 2399b MILK TANK TRUCK INSPECTION REPOR
History
- Author: G. M. Gallaspy, Jr.
- Authority: Code of Ala. 1975, §§22-2-2, 22-20-7.
- Repealed and New Rule: Filed October 18, 2018; effective December 2, 2018.
Ala. Admin. Code r. 420-3-16-AN Appendix N - Drug Residue Teting and Farm Surveillance
I. INDUSTRY RESPONSIBILITIES MONITORING AND SURVEILLANCE
Industry shall screen all bulk milk pickup tankers and/or all raw milk supplies that have not been transported in bulk milk pickup tankers, regardless of final use, for Beta lactam drug residues. Additionally, other drug residues shall be screened for by employing a random sampling program on bulk milk pickup tankers and/or all raw milk supplies that have not been transported in bulk milk pickup tankers when the Commissioner of the FDA determines that a potential problem exists as cited in Rule 420-3-16-.07. The random bulk milk pickup tanker and/or all raw milk supplies that have not been transported in bulk milk pickup tankers sampling program shall represent and include, during any consecutive six (6) months, at least four (4) samples collected in at least four (4) separate months, except when three (3) months show a month containing two (2) sampling dates separated by at least twenty (20) days. Samples collected under this random sampling program shall be analyzed as specified by the FDA (refer to Rule 420-3-16-.07).
The bulk milk pickup tanker shall be sampled after the last producer has been picked up and before any additional commingling. These bulk milk pickup tanker samples may be collected using an approved aseptic sampler. The sample shall be representative. Bulk milk pickup tanker testing shall be completed prior to processing the milk. Bulk milk pickup tanker samples confirmed positive for drug residues using approved test methods and/or verified screening positive using test methods not evaluated by the FDA and accepted by the NCIMS without additional confirmation required shall be retained as determined necessary by the Health Officer.
All raw milk supplies that have not been transported in bulk milk pickup tankers shall be sampled prior to processing the milk. The sample(s) shall be representative of each farm bulk milk tank(s)/silo(s), milk plant raw milk tank(s) and/or silo(s), other raw milk storage container(s), etc. Testing of all raw milk supplies that have not been transported in bulk milk pickup tankers shall be completed prior to processing the milk.
Note: On-farm producer/processors that plan to store or ship their raw sheep milk frozen shall sample their raw sheep milk prior to freezing. The sample shall be obtained by a bulk milk hauler or sampler permitted by the Health Officer where the dairy farm is located. The raw sheep milk sample shall then be tested in a certified laboratory or screening facility. If this is the on-farm producer/processor’s only raw sheep milk supply, this testing would suffice for the required Appendix N testing for all raw milk supplies that have not been transported in bulk milk pickup tankers, which are required to be completed prior to processing the milk. In the case of sheep milk dairy farms, the raw milk sample may be frozen in accordance with a sample protocol approved by the Health Officer in which the dairy farm is located as specified in Appendix B and transported to a certified laboratory for testing. The test results, or raw milk samples, shall clearly distinguish the lot number of the frozen raw sheep milk and accompany the frozen raw sheep milk to the plant.
All presumptive positive test results for drug residues using approved test methods or verified screening positive test results using test methods not evaluated by the FDA and accepted by the NCIMS from analysis conducted on commingled raw milk tanks, bulk milk pickup tankers, and/or all raw milk supplies that have not been transported in bulk milk pickup tankers or farm raw milk tanks/silos (only milk offered for sale) samples shall be reported to the regulatory agency in which the testing was conducted. Bulk milk pickup tanker and/or all raw milk supplies that have not been transported in bulk milk pickup tankers samples confirmed positive for drug residues using approved test methods or verified screening positive using test methods not evaluated by FDA and accepted by the NCIMS without additional confirmation required shall be retained or disposed of as determined by the regulatory agency.
Industry plant samplers shall be evaluated according to the requirements specified in Section 6 and at the frequency addressed in Section 5.
REPORTING AND FARM TRACE BACK
When a bulk milk pickup tanker and/or a raw milk supply that has not been transported in bulk milk pickup tankers is found to be presumptive positive for drug residues using approved test methods or verified screening positive for drug residues using test methods not evaluated by the FDA and accepted by the NCIMS, the regulatory agency in which the testing was conducted
shall be immediately notified of the results and the ultimate disposition of the raw milk.
The producer samples from the bulk milk pickup tanker found to be confirmed positive for drug residues using approved test methods or verified screening positive for drug residues using test methods not evaluated by the FDA and accepted by the NCIMS without additional confirmation required shall be individually tested to determine the farm of origin. The samples shall be tested as directed by the regulatory agency.
Upon official notification to the regulatory agency and milk producer of a violative individual producer’s milk, further farm pickups by bulk milk pickup tankers and/or all raw milk supplies that have not been transported in bulk milk pickup tankers and/or farm use of the violative individual producer’s milk shall be immediately discontinued until such time that subsequent tests are no longer positive for drug residues.
RECORD REQUIREMENTS
Results of all testing may be recorded in any format acceptable to the Health Officer that includes at least the following information:
-
Identity of the person doing the test.
-
Identity of the bulk milk pickup tanker or farm bulk milk tank(s)/ silo(s), milk plant raw milk tank(s) and/or silo(s), other raw milk storage container(s), etc. used for the storage of all raw milk supplies that have not been transported in bulk milk pickup tankers being tested*.
-
Date/time the test was performed (time, day, month and year).
-
Identity of the test performed/lot #/any and all controls (+/-).
-
Results of the test.
6 Follow-up testing if the initial test was positive/any and all controls (+/-).
-
Site where test was performed.
-
Prior test documentation shall be provided for a presumptive positive load.
*Include the BTU number(s) of the dairy farms present on the bulk milk pickup tanker and/or all raw milk supplies that have not been transported in bulk milk pickup tankers with the above information.
Records of all sample test results shall be maintained for a minimum of six (6) months by the industry at the location where the test methods were run and/or another location as directed by the regulatory agency and as agreed to by industry. For the laboratory survey, two (2) years of records shall be available at the facility at the time of the survey.
II. REGULATORY AGENCY RESPONSIBILITIES
Upon receipt of notification from industry of a bulk milk pickup tanker and/or a raw milk supply that has not been transported in bulk milk pickup tankers, which contains milk from another regulatory agency’s jurisdiction, is found to be presumptive positive for drug residues using approved test methods or verified screening positive for drug residues using test methods not evaluated by the FDA and accepted by the NCIMS, it is the responsibility of the receiving regulatory agency to notify the regulatory agency(ies) from which the milk originated.
MONITORING AND SURVEILLANCE
Regulatory agencies shall monitor industry surveillance activities during either routine or unannounced on-site quarterly inspections to collect samples from bulk milk pickup tankers and/or all raw milk supplies that have not been transported in bulk milk pickup tankers and to review industry records of their sampling program. Samples should be collected and analyzed from at least 10 percent of the bulk milk pickup tankers and/or all raw milk supplies that have not been transported in bulk milk pickup tankers scheduled to arrive on the day of the inspection. The test method used shall be appropriate for the drug being analyzed and shall be capable of detecting the same drugs at the same concentrations as the test method being used by industry. Alternately, the regulatory agency or Laboratory Evaluation Officer (LEO) may take known samples with them on the audit visit and observe the Industry Analyst (IA) test the samples. Receiving locations that choose to certify all receiving IAs certified under the provisions of the NCIMS Laboratory Certification Program are exempt from the sample collection requirements of this section. Receiving locations where all approved receiving IAs and Industry Supervisors (ISs) successfully participate in a biennial on-site evaluation and annual spilt sample comparisons by LEOs are also exempt from the sample collection requirements of this section.
A review shall include, but not be limited to, the following:
-
Is the program an appropriate routine monitoring program for the detection of drug residues?
-
Is the program utilizing appropriate test methods?
-
Is each producer’s milk represented in a testing program for drug residues and tested at the frequency prescribed in Section I for drug residues?
-
Is the program assuring timely notification to the appropriate regulatory agency of positive results, the ultimate disposition of the bulk milk pickup tanker, and/or a raw milk supply that has not been transported in bulk milk pickup tankers and of the trace back to the farm of origin?
-
Is the dairy farm pickup and/or use of the violative individual producer’s milk suspended until subsequent testing establishes the milk is no longer positive for drug residues?
To satisfy these requirements
a. There shall be an agreement between the Health Officer and industry that specifies how this notification is to take place. This notification shall be “timely” for example by telephone or fax, and supported in writing.
b. The ultimate disposition should either be prearranged in a documented agreement between the Health Officer and the industry, or physically supervised by the Health Officer. The milk should be disposed of in accordance with provisions of M-I-06-5 or an FDA and Health Officer reviewed and accepted specific drug residue milk diversion protocol for use as animal feed.
c. All screening test positive (confirmed) loads using an approved test method shall be broken down (producer trace back) using the same or an equivalent test method (M-I-96-10, latest revision). Confirmation tests (load and producer trace back/permit enforcement action) shall be performed by an Official Laboratory, Officially Designated Laboratory or Certified Industry Supervisor (CIS). Positive producers shall be handled in accordance with this appendix.
d. All verified screening test positive loads using test methods not evaluated by the FDA and accepted by the NCIMS without additional confirmation required shall be broken down (producer trace back) using the same test method. Producer trace back shall be performed as cited in a prior documented agreement with the regulatory agency (refer to Section VI). Verified screening positive producers shall be handled in accordance with this appendix.
e. All screening test positive (confirmed) loads shall be broken down (producer trace back) using the same or an equivalent test method (M-I-96-10, latest revision). Confirmation tests (load and producer trace back/permit action) shall be performed by an Official Laboratory, Officially Designated Laboratory, or Certified Industry Supervisor (CIS). Positive producers shall be handled in accordance with this appendix.
f. When a farm bulk milk tank(s)/silo(s), milk plant raw milk tank(s) and/or silo(s), other raw milk storage container(s), etc. is (are) used for a milk plant’s raw milk supply(ies) that has (have) not been transported in bulk milk pickup tankers, is (are) found to be positive (confirmed) for drug residues, the farm of origin of the drug residue has consequently already been determined and further testing is not required to determine the farm of origin. Confirmation tests shall be performed by an Official Laboratory, Officially Designated Laboratory, or Certified Industry Supervisor. Positive producers shall be handled in accordance with this appendix.
g. The suspension and discontinuance of farm bulk milk tank pick up and/or the use of raw milk supplies that have not been transported in bulk milk pickup tankers is the responsibility of the industry; under the direction and supervision of the Health Officer. At the discretion of the Health Officer, records should be maintained by industry and/or the Health Officer that:
(1) Establish the identity of the producer for raw milk supplies that h pickup tankers that tested positive or the producer and the identity of the load that tested positive.
(2) Establish that milk is not picked up or used from the drug residue positive producer until the regulatory agency has fulfilled their obligations under Section II., as applicable, based on the test method utilized, and has cleared the milk for pick up and/or use.
Sufficient records should be reviewed to assure that all bulk milk pickup tankers and/or all raw milk supplies that have not been transported in bulk milk pickup tankers are sampled before additional commingling at the milk receiving facility and the results were made available to the appropriate BTU(s).
The Health Officer shall also perform routine sampling and testing for drug residues determined to be necessary as outlined in Section 6.
ENFORCEMENT
If testing reveals milk positive for drug residues, the milk shall be disposed of in a manner that removes it from the human or animal food chain, except where acceptably reconditioned under FDA Compliance Policy Guide (CPG 7126.20). The Health Officer shall determine the producer(s) responsible for the violation.
Permit Suspension and the Prevention of the Sale of Milk - Any time milk is found to test as a confirmed positive using an approved test method, the regulatory agency shall immediately suspend the producer’s Grade "A” permit or equally effective measures shall be taken to prevent the sale of milk containing drug residues. Upon official notification to the regulatory agency and milk producer of a confirmed positive, future farm pickups by bulk milk pickup tankers and/or all raw milk supplies that have not been transported in bulk milk pickup tankers and/or farm use of the violative individual producer’s milk are prohibited until subsequent testing reveals the milk is free of drug residue.
Prevention of the Sale of Milk - Any time milk is found to test as a verified screening positive for a drug residue using test methods not evaluated by the FDA and accepted by the NCIMS without additional confirmation required, the regulatory agency shall immediately take effective measures to prevent the sale of the milk containing drug residues.
Penalties for Confirmed Positive Milk - The penalty shall be for the value of all milk on the contaminated load and/or raw milk supply that has not been transported in bulk milk pickup tankers plus any costs associated with the disposition of the contaminated load or raw milk supply that has not been transported in bulk milk pickup tankers. The regulatory agency may accept certification from the violative producer’s milk marketing cooperative or purchaser of milk as satisfying the penalty requirements.
Reinstatement - The Grade “A” producer’s permit may be reinstated, or other action taken, to allow the sale of milk for human food when a representative sample taken from the producer’s milk, prior to commingling with any other milk, is no longer positive for drug residue.
Follow-Up - Whenever a drug residue test is confirmed positive using an approved test method or verified screening positive using test methods not evaluated by the FDA and accepted by the NCIMS, an investigation shall be made to determine the cause. The farm inspection is completed by the regulatory agency or its agent to determine the cause of the residue and actions taken to prevent future violations including:
-
On-farm changes in procedures necessary to prevent future occurrences as recommended by the Health Officer.
-
Discussion and education on the Drug Residue Avoidance Control measures outlined in Appendix C.
Permit Revocation - After a third violation for a drug residue in a twelve (12) month period, the Health Officer shall initiate administrative procedures pursuant to the revocation of the producer’s Grade “A” permit under the authority of Section 3, due to repeated violations.
HEALTH OFFICER RECORDS
In regards to the industry reporting a confirmed positive using an approved test method or verified screening positive using test methods not evaluated by the FDA and accepted by the NCIMS tanker and/or a raw milk supply that has not been transported in bulk milk pickup tankers result, the regulatory agency’s records shall indicate the following:
-
What were the Health Officer's directions?
-
When was the Health Officer notified? By whom?
-
What was the identity of the load or farm bulk milk tank(s)/silo(s), milk plant raw milk tank(s) and/or silo(s), other raw milk storage container(s), etc. when used for a milk plant’s raw milk supply(ies) that has (have) not been transported in bulk milk pickup tankers?
-
What screening and/or confirmatory test(s) were used and who were the analyst(s)?
-
What was the disposition of the adulterated milk?
-
Which producer(s) was responsible?
-
Record of negative test results prior to subsequent milk pickup from the violative producer(s).
III. TESTING PROGRAM FOR DRUG RESIDUES ESTABLISHED DEFINITIONS
For purposes of this appendix the following definitions are to be used:
(1) Presumptive Positive - A presumptive positive test is a positive result from an initial testing of a bulk milk pickup tanker and/or raw milk supply that has not been transported in bulk milk pickup tankers using an M-a-85, latest revision, or M-I-92-11 approved test method, which has been promptly repeated in duplicate with positive (+) and negative (-) controls that give the proper results using the same test method, on the same sample, with one (1) or both of these duplicate retests giving a positive result.
(2) Screening Test Positive (Load or Raw Milk Supply that has not been Transported in Bulk Milk Pickup Tankers Confirmation) - A screening test positive (confirmation) result is obtained when the presumptive positive sample is tested in duplicate, using the same or equivalent (M-I-96-10, latest revision) test method as that used for the presumptive positive, with a positive (+) and negative (-) control that gives the proper results, and either or both of the duplicates are positive. A screening test positive (load or farm bulk milk tank(s)/silo(s), milk plant raw milk tank(s) and/or silo(s), other raw milk storage container(s), etc. when used for a milk plant’s raw milk supply(ies) that has (have) not been transported in bulk milk pickup tankers confirmation) is to be performed by an Official Laboratory, Officially Designated Laboratory or CIS using the same or an equivalent test (M-I-96-10, latest revision).
Note: When a farm bulk milk tank(s)/silo(s), milk plant raw milk tank(s) and/or silo(s), other raw milk storage container(s), etc. is used for a milk plant’s raw milk supply(ies) that has not been transported in bulk milk pickup tankers is found to be positive (confirmed) for drug residues using approved test methods, the farm of origin for the drug residue has consequently already been determined and further testing is not required to determine the farm of origin.
(3) Individual Producer Load - An individual producer bulk milk pickup tanker is a bulk milk pickup tanker or a compartment(s) of a bulk milk pickup tanker that contains milk from only one (1) dairy farm.
(4) Individual On-Farm Producer/Processor’s Raw Milk Supply - An individual on-farm producer/processor’s raw milk supply may be transported in bulk milk pickup tankers; and/or their raw milk supply may be stored in a farm bulk milk tank(s)/silo(s) on the dairy farm that directly feeds the batch (vat) pasteurizer(s) or constant-level tank of a HTST pasteurization system or piped from a farm bulk milk tank(s)/silo(s) to a raw milk tank(s) and/or silo(s) in the milk plant that feeds the batch (vat) pasteurizer(s) or constant-level tank of a HTST pasteurization system; and/or other raw milk storage containers.
(5) Industry Analyst - A person under the supervision of a Certified Industry Supervisor (CIS) or Industry Supervisor (IS) who is assigned to conduct screening of bulk milk pickup tankers and/or all raw milk supplies that have not been transported in bulk milk pickup tankers for Appendix N.
(6) Industry Supervisor/Certified Industry Supervisor - An individual trained by a LEO who is responsible for the supervision and training of Industry Analysts (IA) who test milk tank trucks and/or all raw milk supplies that have not been transported in bulk milk pickup tankers for Appendix N.
(7) Certified Industry Supervisor (CIS) - An Industry Supervisor (IS) who is evaluated and listed by a LEO as certified to conduct drug residue screening tests using approved test methods at industry drug residue screening sites for Grade "A" PMO, Appendix N. enforcement actions (confirmation of bulk milk pickup tankers, farm bulk milk tank(s)/silo(s), milk plant raw milk tank(s) and/or silo(s), or other raw milk storage container(s), etc. when used for a milk plant’s raw milk supply(ies) that has (have) not been transported in bulk milk pickup tankers, producer trace back and/or permit actions).
(8) Verified Screening Positive - A verified screening positive test is a positive result from an initial testing using test methods not evaluated by the FDA and accepted by the NCIMS of a bulk milk pickup tanker and/or raw milk supply that has not been transported in bulk milk pickup tankers, which has been promptly repeated in duplicate with positive (+) and negative (-) controls that give the proper results, using the same test method, on the same sample, with one (1) or both of these duplicate retests giving a positive result.
(9) Producer Trace Back With Permit Suspension Action Not Required - A producer trace back test is performed after a verified screening positive load using test methods not evaluated by FDA and accepted by the NCIMS without additional confirmation required is identified by a laboratory using the same test method as was used to obtain the verified screening positive load. A verified screening positive producer test result is obtained in the same manner as a verified screening positive for a bulk milk pickup tanker. After an initial positive result is obtained on a producer sample, that sample is then tested in duplicate using the same test method as was used to obtain the initial producer positive result. This testing is performed with positive (+) and negative (-) controls and if either or both of the duplicates are positive and the controls give the proper results, the producer sample is a verified screening positive (refer to Section VI).
Note: When a farm bulk milk tank(s)/silo(s), milk plant raw milk tank(s) and/or silo(s), other raw milk storage container(s), etc. is used for a milk plant’s raw milk supply(ies) that has not been transported in bulk milk pickup tankers is found to be verified screening positive for drug residues using only test methods not evaluated by the FDA and accepted by the NCIMS without additional confirmation required, the farm of origin for the drug residue has consequently already been determined and further testing is not required to determine the farm of origin.
CERTIFIED INDUSTRY SUPERVISORS; EVALUATION AND RECORDS
Reference: EML
- Certified Industry Supervisors (CISs)/Industry Supervisors (ISs)/Industry Analysts (IAs) - Regulatory agencies may choose to allow ISs to be certified. Under this program, these CISs may officially confirm presumptive positive bulk milk pickup tanker loads and/or all raw milk supplies that have not been transported in bulk milk pickup tankers, and confirm producer milk for regulatory purposes (producer trace back/permit action) using approved test methods. In the implementation of Appendix N, the LEO shall use the appropriate Appendix N FDA/NCIMS 2400 Form when evaluating Official Laboratories, Officially Designated Laboratories, or CISs, ISs, and IAs.
The Certified Industry Supervisor/Industry Supervisor shall report to the LEO the results of all competency evaluations performed on Industry Analysts. The names of all Certified Industry Supervisors, Industry Supervisors, and Industry Analysts, as well as their training and evaluation status, shall be maintained by the LEO and updated as replacement, additions, and/or removals occur. The LEO shall verify (document) that each Certified Industry Supervisor and/or Industry Supervisor has established a program that ensures the proficiency of the Industry Analysts they supervise. The LEO shall also verify that each Industry Supervisor and Industry Analyst has demonstrated proficiency in performing drug residue analysis at least biennially. Verification may include an analysis of split samples and/or an on-site performance evaluation or another proficiency determination that the LEO and the FDA Laboratory Proficiency Evaluation Team (LPET) agree is appropriate.
Failure by the Industry Supervisor or Industry Analyst to demonstrate adequate proficiency to the LEO shall lead to their removal from the LEO list of Industry Supervisors and/or Industry Analysts. Reinstatement of their testing status shall only be possible by completing retraining and/or successfully analyzing split samples and/or passing an on-site evaluation or otherwise demonstrating proficiency to the LEO (refer to the EML, which describes the certification requirements for Certified Industry Supervisors and the training requirements for Industry Supervisors and Industry Analysts).
-
Sampling and Testing of Bulk Milk Pickup Tankers - The bulk milk pickup tanker shall be sampled after the last producer has been picked up and before any additional commingling. The sample shall be representative. The sample analysis shall be completed before the milk is processed.
-
Sampling and Testing of Raw Milk Supplies that have Not been Transported in Bulk Milk Pickup Tankers - All raw milk supplies that have not been transported in bulk milk pickup tankers shall be sampled prior to processing the milk. The sample(s) shall be representative of each farm bulk milk tank(s)/silo(s), milk plant raw milk tank(s) and/or silo(s), or other raw milk storage container(s) supply. Testing of all raw milk supplies that have not been transported in bulk milk pickup tankers shall be completed prior to processing the milk.
-
Bulk Milk Pickup Tanker Unloaded Prior to Negative Test Result - If the bulk milk pickup tanker is unloaded and commingled prior to obtaining a negative test result and the screening test is presumptive positive using an approved test method or verified screening positive using test methods not evaluated by the FDA and accepted by the NCIMS, the regulatory agency shall be immediately notified. If the bulk milk tanker sample is confirmed positive using an approved test method or verified screening positive using test methods not evaluated by the FDA and accepted by the NCIMS without additional confirmation required then the commingled milk is adulterated and unacceptable for human consumption regardless of any subsequent test results from the commingled milk. The milk shall be disposed of under the supervision of the regulatory agency.
-
Raw Milk Supplies that have Not been Transported in Bulk Milk Pickup Tankers Processed Prior to Negative Results - If the raw milk supply that has not been transported in bulk milk pickup tankers is processed prior to obtaining a negative test result and the screening test is presumptive positive using an approved test method or verified screening positive using test methods not evaluated by FDA and accepted by the NCIMS, the regulatory agency shall be immediately notified. If the sample of the raw milk supply that has not been transported in bulk milk pickup tankers is confirmed positive using an approved test method or verified screening positive using test methods not evaluated by the FDA and accepted by the NCIMS without additional confirmation required then the processed milk is adulterated and unacceptable for human consumption regardless of any subsequent test results from the raw milk supply and/or pasteurized milk or milk products. The processed milk shall be disposed of under the supervision of the regulatory agency.
BULK MILK PICKUP TANKER AND/OR ALL RAW MILK SUPPLIES THAT HAVE NOT BEEN TRANSPORTED IN BULK MILK PICKUP TANKERS SCREENING TEST
-
Performance Tests/Controls - Each lot of test kits purchased shall be tested by positive (+) and negative (-) controls in each screening facility prior to its initial use and each testing day thereafter. Records of all positive (+) and negative (-) control performance tests shall be maintained.
-
Initial Drug Testing Procedures - The following procedures apply to testing bulk milk pickup tankers and/or all raw milk supplies that have not been transported in bulk milk pickup tankers for drug residues following the provisions of Appendix N. Industry analysts may screen tankers and/or all raw milk supplies that have not been transported in bulk milk pickup tankers and receive or reject milk. Milk plants, receiving stations, transfer stations, and other screening locations may choose to participate in the Industry Supervisor Certification Program.
a. Industry Presumptive Positive Options - There are two (2) industry options for the milk represented by a presumptive positive sample:
(1) The regulatory agency involved (origin and receipt) shall be notified. The appropriate regulatory agency shall take control of the presumptive positive load and/or raw milk supply that has not been transported in bulk milk pickup tankers. A written copy of the presumptive positive test results shall follow the initial regulatory agency notification. Testing for confirmation of that presumptive positive load and/or raw milk supply that has not been transported in bulk milk pickup tankers shall be in an Official Laboratory, Officially Designated Laboratory, or by a Certified Industry Supervisor at a location acceptable to the Health Officer. Documentation of prior testing shall be provided to the analyst performing the load and/or raw milk supply that has not been transported in bulk milk pickup tankers confirmation. The presumptive positive load and/or raw milk supply that has not been transported in bulk milk pickup tankers may be re-sampled, at the direction of the regulatory agency, prior to analysis with the same or equivalent test (M-I-96-10, latest revision), as was used to obtain the presumptive positive result. This analysis shall be done in duplicate with positive (+) and negative (-) controls. If either or both of the duplicate samples are positive and the positive (+) and negative (-) controls give the correct reactions, the sample is deemed a Screening Test Positive (Confirmed Load and/or Raw Milk Supply that has Not been Transported in Bulk Milk Pickup Tankers Confirmation). A written copy of the test results shall be provided to the regulatory agency. The milk which that sample represents is no longer available for sale or processing into human food.
(2) The owner of the presumptive positive milk may reject the load and/or raw milk supply that has not been transported in bulk milk pickup tankers without further testing. At that time, the milk represented by the presumptive positive test is not available for sale or processing into human food. The milk cannot be re-screened. The Health Officer involved (origin and receipt) shall be notified. Under this option, producer trace backs shall be conducted for the reject load.
Note: When a farm bulk milk tank(s)/silo(s), milk plant raw milk tank(s) and/or silo(s), other raw milk storage container(s), etc. is used for a milk plant’s raw milk supply(ies) that has not been transported in bulk milk pickup tankers is found to be positive (confirmed) for drug residues, the farm of origin for the drug residue has consequently already been determined and further testing is not required to determine the farm of origin.
- Re-Sampling
a. Presumptive Results Using Approved Test Methods - Occasionally, an error in sampling or a suspicious test result is discovered after a presumptive result is initially obtained using approved test methods. When this happens, the regulatory agency may allow the industry to re-sample the bulk milk pickup tanker and/or raw milk supply that has not been transported in bulk milk pickup tankers. The reasons that made the re-sampling necessary shall be clearly documented in testing records and reported to the regulatory agency. This written record shall be provided to the regulatory agency and shall be maintained with the record of the testing for that load and/or raw milk supply that has not been transported in bulk milk pickup tankers.
b. Screening Test Results Using Approved Test Methods - Re-sampling or additional analysis of screening test results should be discouraged. However, the regulatory agency may direct re-sampling and/ or analysis, when it has determined that procedures for sampling and/or analysis did not adhere to accepted NCIMS practices (SMEDP, FDA/NCIMS 2400 Forms, Appendix N. and the applicable FDA interpretative or informational memoranda). This decision by the regulatory agency shall be based on objective evidence. A regulatory agency allowing re-sampling shall plan a timely follow-up to identify the problem and initiate corrective action to ensure the problem that led to the need for re-sampling is not repeated. If re-sampling and/or analysis are necessary, it shall include a review of the samplers, analysts, and/or laboratories to identify the problem(s) and initiate corrective action to ensure the problem(s) is not repeated. The reasons that made the re-sampling or analysis necessary shall be clearly documented in testing records maintained by the regulatory agency, and shall be maintained with the record of the testing for that load and/or raw milk supply that has not been transported in bulk milk pickup tankers. Producer Trace Back
a. All screening test confirmed positive loads using an approved test method shall be broken down (producer trace back) using the same or an equivalent test method (M-I-96-10, latest revision). Confirmation tests (load and producer trace back/permit action) shall be performed in an Official Laboratory, Officially Designated Laboratory, or by a CIS. Positive producers shall be handled in accordance with this appendix.
Note: When a farm bulk milk tank(s)/silos, milk plant raw milk tank(s) and/or silo(s), other raw milk storage container(s), etc. is used for a milk plant’s raw milk supply(ies) that has not been transported in bulk milk pickup tankers is found to be confirmed positive for drug residues using an approved test method, the farm of origin for the drug residue has consequently already been determined and further testing is not required to determine the farm of origin.
b. All verified screening positive loads using test methods not evaluated by the FDA and accepted by the NCIMS without additional confirmation required shall be broken down (producer trace back) using the same test method. Verification producer trace back tests shall be performed as cited in a prior documented agreement with the regulatory agency (refer to Section VI). Verified screening positive producers shall be handled in accordance with this appendix.
Note: When a farm bulk milk tank(s)/silos, milk plant raw milk tank(s) and/or silo(s), other raw milk storage container(s), etc. is used for a milk plant’s raw milk supply(ies) that has not been transported in bulk milk pickup tankers, is found to be verified screening positive for drug residues using test methods not evaluated by FDA and accepted by the NCIMS without additional confirmation required the farm of origin for the drug residue has consequently already been determined and further testing is not required to determine the farm of origin.
Assuring Representative Samples From Individual - Producer Loads And Multiple-Farm Tank Loads From An Individual Producer Representative samples shall be secured from each farm storage tank(s)/silo(s) of milk prior to loading onto a bulk milk pickup tanker and/or other raw milk supply transportation method at the dairy farm. The representative sample(s) shall travel with the bulk milk pickup tanker and/or other raw milk supply transportation method to a designated location acceptable to the regulatory agency.
Record Requirements - Results of all testing may be recorded in any format acceptable to the Health Officer that includes at least the following information:
-
Identity of the person doing the test.
-
Identity of the bulk milk pickup tanker or farm bulk milk tank(s)/silo(s), milk plant raw milk tank(s) and/or silo, or other raw milk storage container(s), etc. used for the storage of raw milk supplies that have not been transported in bulk milk pickup tankers being tested*.
-
Date/time the test was performed (time, day, month and year).
-
Identity of the test performed/lot #/any and all controls (+/-).
-
Results of the test, if the analysis results are positive the record shall show:
a. The identity of each producer contributing to the positive load.
b. Who at the Health Officer was notified.
c. When did this notification take place.
d. How was this notification accomplished.
-
Follow-up testing if initial test was positive/any and all controls (+/-).
-
Site where test was performed.
-
Prior test documentation shall be provided for a presumptive positive load.
Include the BTU number(s) of the dairy farms present on the bulk milk pickup tanker and/or all raw milk supplies that have not been transported in bulk milk pickup tankers with the above information.
SCREENING TESTS NECESSARY TO IMPLEMENT THE PROVISIONS OF APPENDIX N FOR BULK MILK PICKUP TANKERS AND/OR ALL RAW MILK SUPPLIES THAT HAVE NOT BEEN TRANSPORTED IN BULK MILK PICKUP TANKERS
- Performance Tests/Controls (+/-):
a. Each lot of kits purchased is tested by positive (+) and negative (-) controls.
b. Each screening facility runs a positive (+) and negative (-) control performance test each testing day.
c. All NCIMS approved bulk milk pickup tanker and/or all raw milk supplies that have not been transported in bulk milk pickup tankers screening tests include the following format: All presumptive positive test results shall be repeated in duplicate as soon as possible at the direction of the regulatory agency on the same sample with single positive (+) and negative (-) controls by a certified analyst (Official Laboratory, Officially Designated Laboratory, or Certified Industry Supervisor) using the same or equivalent test (M-I-96-10, latest revision). If the duplicate tests are negative, with appropriate (+/-) control results, the bulk milk pickup tanker and/or all raw milk supplies that have not been transported in raw milk bulk milk pickup tankers is reported as negative. If one (1) or both duplicate test(s) is positive (+), the test result is reported to the regulatory agency in which the testing was conducted, as a screening test positive (confirmed).
d. All test methods used by industry, which have not been evaluated by the FDA and accepted by the NCIMS for bulk milk pickup tanker and/or all raw milk supplies that have not been transported in bulk milk pickup tankers include the following format: One (1) of the options provided for in Section VI of this Appendix shall be followed.
e. All positive (+) controls used for drug residue testing kits are labeled to indicate a specific drug and concentration level for that drug.
(1) For tests that have been validated and only detect Penicillin, Ampicillin, Amoxicillin, and Cephapirin, the positive (+) control is Pen G @ 5 ± 0.5 ppb.
(2) For test kits validated for the detection of Cloxacillin, the positive (+) control may be Cloxacillin @ 10 ± 1 ppb.
(3) For test kits validated for one (1) drug residue only, the positive (+) control is ± 10% of the safe level/tolerance of the drug residue detected.
- Work Area
a. Temperature within specifications of the test kit manufacturer's labeling.
b. Adequate lighting for conducting the test kit procedure.
- Test Kit Thermometers
a. Thermometer traceable to a NIST Certified Thermometer.
b. Graduation interval not greater than 1°C.
c. Dial thermometers are not used to determine the temperatures of samples, reagents, refrigerators, or incubators in milk laboratories.
- Refrigeration
a. Test kit reagent storage temperature specified by manufacturer.
- Balance (Electronic)
a. 0.01 g for preparation of positive (+) controls.
b. Balance with appropriate sensitivity for calibration of pipetting devices within a tolerance of ± 5%. These devices may be calibrated at another location acceptable to the LEO.
- Screening Test Sampling Requirements
a. Temperature of milk in the bulk milk pickup tanker and/or all raw milk supplies that have not been transported in bulk milk pickup tankers determined and recorded.
b. Representative bulk milk pickup tanker and/or all raw milk supplies that have not been transported in bulk milk pickup tankers sample for drug residue testing collected.
c. Samples tested within seventy-two (72) hours of collection.
- Screening Test Volumetric Measuring Devices
a. Single use devices provided by kit manufacturers are acceptable for Appendix N screening analysts.
b. NCIMS certified laboratories require calibrated pipetting/dispensing devices. These devices may be calibrated at another location acceptable to the LEO.
c. Measuring devices with tips bearing calibration lines provided by test kit manufacturers are acceptable for Appendix N screening.
IV. ESTABLISHED TOLERANCES AND/OR SAFE LEVELS OF DRUG RESIDUES
"Target testing levels" are used by the FDA as guides for prosecutorial discretion. They do not legalize residues found in milk that are below the target testing levels. In short, the FDA uses the "target testing levels" as prosecutorial guidelines and in full consistency with CNI v. Young. They do not dictate any result; they do not limit the FDA's discretion in any way; and they do not protect milk producers or milk from court enforcement action.
"Target testing levels" are not and cannot be transformed into tolerances that are established for animal drugs under Section 512 (b) of the FFD&CA as amended. "Target testing levels" do not:
-
Bind the courts, the public, including milk producers, or the FDA, including individual FDA employees.
-
Do not have the "force of law" of tolerances, or of binding rules.
Notification, changes, or additions of "target testing levels" shall be transmitted via Memoranda of Information (M-I's).
V. APPROVED TEST METHODS
Regulatory agencies and industry shall use test methods from M-a-85, latest revision, for analysis of bulk milk pickup tankers and/or all raw milk supplies that have not been transported in raw milk bulk milk pickup tankers for Beta lactams residues, following the testing procedures specified in Section III of this Appendix. AOAC First Action and AOAC Final Action methods are accepted in accordance with Section 6. Enforcement action based on each test method may be delayed until the evaluation is completed and the method is found to be acceptable to the FDA and complies with the provisions of Rule 420-3-16-.07.
One (1) year after two (2) or more drug test methods have been evaluated by the FDA and accepted by the NCIMS for a particular non-Beta lactam drug or drug family, other unevaluated drug test methods for that particular non-Beta lactam drug or drug family are not acceptable for determining a Screening Test Positive (Confirmation) on a milk tank truck load of milk and/or all raw milk supplies that has not been transported in bulk milk pickup tankers. The acceptance of evaluated drug test methods by the FDA and the NCIMS for drugs other than Beta lactams does not mandate any additional screening by industry or regulatory agencies with the evaluated drug test method, unless it is determined by the Commissioner of the FDA that a potential problem exists with other animal drug residues in the milk supply.
New drug test methods which are submitted to NCIMS from the FDA for acceptance shall not detect drug residues at less than 50 percent of the tolerance level or 25 percent of the target testing level* for individual drugs, with the exception of the following that may be accepted for Appendix N and other drug testing:
-
Penicillin G at 2 ppb.
-
Tetracycline drug kits that detect tetracyclines at levels greater than 150 ppb for Chlortetracycline, 119 ppb for Oxytetracycline, and 67 ppb for Tetracycline.
*Target testing levels are set by the FDA based on available science. They are not determined by the detection limits of commercially available test methods.
VI. TEST METHODS FOR NON-BETA LACTAMS RESIDUE TESTING THAT HAVE NOT BEEN EVALUATED BY FDA AND ACCEPTED BY THE NCIMS
Provided, that until at least two (2) test methods are found acceptable by the FDA and the NCIMS for detecting a particular drug or drug family, other than Beta lactams, as cited in M-a-85, latest revision, and M-I-92-11 in raw milk, non-Beta lactam screening test methods, which have not been evaluated and accepted by the FDA and the NCIMS, may be used for the initial screening, provided that the test method manufacturer’s data indicates that testing sensitivity is at or below U.S. target testing/ or tolerance levels.
UTILIZING A DRUG TEST METHOD THAT HAS NOT BEEN EVALUATED BY FDA AND ACCEPTED BY THE NCIMS FOR INITIAL SCREENING FOLLOWED BY A DRUG TEST METHOD THAT HAS BEEN EVALUATED BY FDA AND ACCEPTED BY THE NCIMS (M-a-85, latest revision, and M-I-92-11) FOR DETERMINING A SCREENING TEST POSITIVE (LOAD AND/OR RAW MILK SUPPLY THAT HAS NOT BEEN TRANSPORTED IN BULK MILK PICKUP TANKERS CONFIRMATION)
Test methods not evaluated by the FDA and accepted by the NCIMS may be used for screening bulk milk pickup tankers and/or all raw milk supplies that have not been transported in raw milk bulk milk pickup tankers for non-Beta lactam drug residues with the documented permission of the regulatory agency(ies). In advance of using such a test method, a prior documented agreement shall be obtained among the user of the test method, the milk supplier, and the regulatory agency(ies) to determine the facility and protocols to be used to confirm the presence of a non- Beta lactam drug residue with a test method evaluated by FDA and accepted by the NCIMS as cited in M-a-85, latest revision, and M-I-92-11. An M-I-96-10, latest revision, test method(s) shall be used for confirmation.
One (1) of the following two (2) options (1 or 2) shall be used for confirmation:
-
If the initial test result from a drug test method that has not been evaluated by the FDA and accepted by the NCIMS is found to be positive, testing shall promptly be repeated in duplicate with positive (+) and negative (-) controls that give the proper results using the same test method on the same sample. The initial test result is verified as a screening positive when one (1) or both of these duplicate retests give a positive result. The regulatory agency involved (origin and receipt) shall be notified. The appropriate regulatory agency shall take control of the verified screening positive load and/or raw milk supply that has not been transported in bulk milk pickup tankers. A written copy of the verified screening positive test results shall follow the initial regulatory agency notification. Testing for confirmation of that verified screening positive load and/or raw milk supply that has not been transported in bulk milk pickup tankers shall utilize a test method from M-a-85, latest revision, and M-I-92-11, and shall be conducted in an Official Laboratory, Officially Designated Laboratory, or by a CIS at a location acceptable to the regulatory agency. Documentation of all prior testing shall be provided to the analyst performing the load and/or raw milk supply that has not been transported in bulk milk pickup tanker’s confirmation. The verified screening positive load and/or raw milk supply that has not been transported in bulk milk pickup tankers may be re-sampled, at the direction of the regulatory agency, prior to analysis with an M-I-96-10, latest revision, test method. This analysis shall be done in duplicate with positive (+) and negative (-) controls. If either or both of the duplicate samples are positive and the positive (+) and negative (-) controls give the proper results, the sample is deemed a Screening Test Positive (load and/or raw milk supply that has not been transported in bulk milk pickup tanker’s confirmation). A written copy of the test results shall be provided to the regulatory agency. The milk which that sample represents is no longer available for sale or processing into human food. Producer trace back, reporting, and enforcement as defined in this appendix shall occur.
-
If the initial test result from a drug test method that has not been evaluated by the FDA and accepted by the NCIMS is found to be positive, the sample shall promptly be retested using a test method from M-a-85, latest revision, and M-I-92-11. The initial positive M-a-85 and M-I-92-11 test is found to be a presumptive positive by promptly repeating in duplicate with positive (+) and negative (-) controls that give the proper results, using the same test method, on the same sample, with one (1) or both of these duplicate retests giving a positive result. The regulatory agency involved (origin and receipt) shall be notified. The appropriate regulatory agency shall take control of the presumptive positive load and/or raw milk supply that has not been transported in bulk milk pickup tankers. A written copy of the presumptive positive test results shall follow the initial regulatory agency notification. Testing for confirmation of that presumptive positive load and/or raw milk supply that has not been transported in bulk milk pickup tankers shall be conducted in an Official Laboratory, Officially Designated Laboratory or by a CIS at a location acceptable to the regulatory agency. Documentation of all prior testing shall be provided to the analyst performing the load and/or raw milk supply that has not been transported in bulk milk pickup tanker’s confirmation. The presumptive positive load and/or raw milk supply that has not been transported in bulk milk pickup tankers may be re-sampled, at the direction of the regulatory agency, prior to analysis with an M-I-96-10, latest revision, test method. This analysis shall be done in duplicate with positive (+) and negative (-) controls. If either or both of the duplicate samples are positive and the positive (+) and negative (-) controls give the proper results, the sample is deemed a Screening Test Positive (load and/or raw milk supply that has not been transported in bulk milk pickup tanker’s confirmation). A written copy of the test results shall be provided to the regulatory agency. The milk which that sample represents is no longer available for sale or processing into human food. Producer trace back, reporting, and enforcement as defined in this appendix shall occur.
UTILIZING A DRUG TEST METHOD THAT HAS NOT BEEN EVALUATED BY FDA AND ACCEPTED BY THE NCIMS FOR THE INITIAL SCREENING AND DETERMINING A VERIFIED SCREENING POSITIVE LOAD AND/OR RAW MILK SUPPLY THAT HAS NOT BEEN TRANSPORTED IN BULK MILK PICKUP TANKERS WHEN A DRUG TEST METHOD THAT HAS BEEN EVALUATED BY FDA AND ACCEPTED BY THE NCIMS (M-a-85, latest revision, and M-I-92-11) IS NOT AVAILABLE
Test methods not evaluated by the FDA and accepted by the NCIMS may be used for screening and verifying bulk milk pickup tankers and/or all raw milk supplies that have not been transported in raw milk bulk milk pickup tankers for non-Beta lactam drug residues with the documented permission of the regulatory agency(ies). In advance of using such a test method, a prior documented agreement shall be obtained among the user of the test method, the milk supplier, and the regulatory agency(ies) to determine the facility and protocols to be used to verify the presence of a non-Beta lactam drug residue.
If the initial test result from a drug test method that has not been evaluated by the FDA and accepted by the NCIMS is found to be positive, the sample shall promptly be retested in a facility identified in the prior documented agreement using the same drug test method. The initial positive test is found to be a verified screening positive by promptly repeating in duplicate with positive (+) and negative (-) controls that give the proper results, using the same test, on the same sample, with one (1) or both of these duplicate retests giving a positive result. The regulatory agency involved (origin and receipt) shall be notified. The appropriate regulatory agency may take control of the verified screening positive load and/or raw milk supply that has not been transported in bulk milk pickup tankers. A written copy of the verified screening positive test results shall follow the initial regulatory agency notification. The verified screening positive load and/or raw milk supply that has not been transported in bulk milk pickup tankers shall be disposed of to remove it from the human or animal food chain. Producer trace back shall be conducted by industry using the same drug test method at the direction of the regulatory agency as cited in the prior documented agreement. If the initial producer test result from the drug test method is found to be positive, the sample shall promptly be retested in a facility identified in the prior documented agreement using the same drug test method. The initial positive test is found to be a verified producer screening positive by promptly repeating in duplicate with positive (+) and negative (-) controls that give the proper results, using the same test method, on the same sample, with one (1) or both of these duplicate retests giving a positive result. The regulatory agency shall be notified of the producer trace-back results. The verified screening positive milk is removed from the human and/or animal food chain, which is managed between the user of the test method, the milk supplier, and the dairy producer. Future pickups and/or use of the violative individual producer’s milk are prohibited until subsequent testing, utilizing the same drug test method or equivalent that has not been evaluated by the FDA and accepted by the NCIMS, of a representative sample taken from the producer’s milk, prior to commingling with any other milk, is no longer positive for drug residue. Whenever a drug residue test is verified screening positive, an investigation may be completed by the regulatory agency or its agent to determine the cause of the drug residue and actions taken to prevent future violations.
Note: When a farm bulk milk tank(s)/silo(s), milk plant raw milk tank(s) and/or silo(s), other raw milk storage container(s), etc. is used for a milk plant’s raw milk supply(ies) that has not been transported in bulk milk pickup tankers is found to be confirmed positive for drug residues using an approved test method or verified screening positive for drug residues using test methods not evaluated by FDA and accepted by the NCIMS without additional confirmation required, the farm of origin for the drug residue has consequently already been determined and further testing is not required to determine the farm of origin.
History
- Author: G. M. Gallaspy, Jr.
- Authority: Code of Ala. 1975, §§22-2-2, 22-20-7.
- Repealed and New Rule: Filed October 18, 2018; effective December 2, 2018.
Ala. Admin. Code r. 420-3-16-AO Appendix O - Vitamin Fortification of Fluid Milk Products
PROCESS/METHODS OF VITAMIN ADDITION
Vitamin fortification can be accomplished by the addition of vitamins at many different points in the processing system, preferably after separation, including the pasteurizing vat, to the HTST constant-level tank, or on a continuous basis into the pipeline after standardization and prior to pasteurization in accordance with the manufacturer's recommendations. Both batch addition and addition with metering pumps can be used. The batch procedure requires accurate measurement of the volume of milk to be fortified, accurate measurement of the vitamin concentrate, and proper mixing. When a vitamin metering pump(s) is used with an HTST or HHST unit, the pump(s) shall be installed so as to be activated only when the unit is in forward-flow. The addition of vitamins shall be accomplished prior to pasteurization in accordance with the manufacturer's recommendations.
The problem of under fortification is often related to the point in the system where fortification takes place. Vitamins A and D are fat-soluble and will gradually become more concentrated in the milk fat portion of the milk. Both oil and water base vitamins are susceptible to this migration problem.
If vitamins are added in the proper amount before separation and standardization, and the product is separated and standardized, then the low fat product will tend to be under fortified and the high fat product over fortified. Water-soluble vitamin concentrates can minimize this problem if vitamins are added before separation. Processors who use this procedure should perform confirmatory assays to ensure proper fortification levels of each product.
Many HTST systems are now being used with in-line fat standardization, which also makes possible switching, without stopping, from milk and milk products being fortified with vitamin D to those being fortified with both A and D. These systems require metered injection of the proper vitamins at a point after standardization and before pasteurization. Sanitary positive-displacement pumps are available for this purpose.
There are two (2) types available:
-
The first is a piston type metering pump without valves. It is equipped with a micrometer which allows accurate and reproducible amounts of vitamins to be added based on the rate of product flow through the system.
-
The other type is a peristaltic pump that offers precise control. This precise control is possible since the volume can be controlled by the tubing size and the pump speed. This system simplifies cleaning since only the tube is in contact with the vitamin concentrates.
These pumps have a history of reproducibility and reliability. All metering pumps should be designed to conform with these rules.
The recommended injection point is after separation and prior to homogenization. This allows the homogenization process to distribute the vitamins throughout the milk. A check-valve is recommended to prevent milk from contaminating the vitamin concentrate.
Separate pumps, tubing, and check-valves are recommended when multiple types of vitamin concentrates are injected (refer to Figure 58).
Pumps should be calibrated based on the pasteurization system flow rate. If flow rates change for different milk products, additional vitamin pumps may be needed. Re-calibration of the metering pumps is not recommended without verifying the accuracy. Routine calibration of metering pumps is recommended. The following are recommended to achieve desired vitamin fortification levels:
-
Management shall be committed to proper fortification and concerned with both over and under levels.
-
Design the system correctly for proper addition in which concentrate is added after standardization and before pasteurization.
-
Written procedures and training should be provided to all employees responsible for vitamin fortification for each milk and milk product to be fortified. These procedures should focus on milk or milk product start-up and milk or milk product change-over.
-
Maintain accurate records of vitamins used and milk and milk products produced, checked daily against theoretical use. Care should be taken that adequate fortification of small run milk or milk products like skim milk is not masked by much larger volumes of reduced fat 2 percent or other partly skimmed milk products.
METERING PUMPS
Use an accurate, sanitary, positive-displacement metering pump with a scheduled cleaning procedure after use. For batch addition, use only accurate, calibrated measuring devices such as plastic graduated cylinders or pipettes. Measuring devices should be sized to the amount of concentrate added, i.e., if 8 mL is added, a 10 mL graduated cylinder would be appropriate. Measuring devices should be rinsed with the milk or milk product being fortified to ensure no residual concentrate is left. Use a check-valve on the injection line to prevent milk or milk product from being pushed back into the line. This depends on the pump displacement. Check the meter calibration regularly, including both the pump and the tubing, by determining delivery rate accuracy. Use only properly calibrated tubing for peristaltic pump systems and replace the tubing regularly.
Storage vessels used for supplying vitamin concentrate to metering pumps should be emptied on a regular basis. A regular systematic cleaning and sanitizing schedule shall be maintained for these vessels, pumps, and tubing. Vitamin concentrates should be stored and held in accordance with the manufacturer's recommendations for maximum shelf life.
Vitamin metering pumps should be interwired with the flow divert and recycle valves to prevent operation during divert and/or recycle flows.
Analyze finished products regularly. Results should be reported in International Units (I.U.)/Quart. Because of the sensitivity and difficulty in performing these tests, it is necessary to procure the services of a competent laboratory; one that is familiar with the handling and testing of vitamin fortified dairy products.
Care shall be taken when reprocessing reclaimed product so vitamin A and/or D levels do not exceed the label claims by more than 150 percent.
GOOD MANUFACTURING PRACTICES
Good manufacturing practices require that the vitamin A and D levels be in compliance with 21 CFR 131.110 states: “(b) Vitamin addition (Optional). (1) If added, vitamin A shall be present in such quantity that each quart of the food contains not less than 2000 I.U. thereof within limits of good manufacturing practices. (2) If added, vitamin D shall be present in such quantity that each quart of the food contains 400 I.U. thereof within limits of good manufacturing practice.”
For the purpose of label claims, compliance for nutritional labeling of food 21 CFR 101.9 applies and states:
(3) (i) Class I. Added nutrients in fortified or fabricated foods.
(4) (i) Class I vitamins, mineral, protein, dietary fiber, or potassium. The nutrient content of the composite is at least equal to the value for that nutrient declared on the label.
Therefore, if added, the acceptable range for vitamins A and D in the standardized milk products listed in 21 CFR, 131.110 Milk, 131.111 Acidified Milk, 131.112 Cultured Milk, 131.127 Nonfat Dry Milk Fortified with vitamins A and D (vitamin addition not optional), 131.200 Yogurt, 131.203 Lowfat Yogurt, and 131. 206 Nonfat Yogurt are as follows:
*100-150 percent of label claims = (400 - 600 I.U. per quart for vitamin D and 2000 - 3000 I.U. per quart for vitamin A)
*Within method variability
Fluid milk products found below 100 percent or above 150 percent of the required values or label claims should be resampled and the cause of the problem determined.
Additionally, 21 CFR 130.10 - Requirements for foods named by use of a nutrient content claim and a standardized term states: "That nutrients must be added to the food to restore nutrient levels so that the product is not nutritionally inferior to the standardized food for products which combine a nutrient content claim, i.e., lowfat, non-fat, or reduced fat, with a standardized term, i.e., milk, sour cream, eggnog." Therefore, vitamins A and D shall be added to dairy products from which fat has been removed; such as, reduced fat, lowfat, and nonfat dairy products, in an amount necessary to replace the amount of these vitamins lost in the removal of fat.
TESTING METHODS
Test methods used for the detection of vitamins A and/or D shall be acceptable to the FDA or other official methodologies that give statistically equivalent results to the FDA methods. Vitamin analysis shall be conducted in a laboratory accredited by the FDA and acceptable to the Health Officer (refer to M-a-98, latest revision, for the specific milk and/or milk products that have FDA validated and NCIMS accepted test methods for vitamins).
TYPE OF CONCENTRATES AVAILABLE
A number of different types of concentrates are available. All contain vitamin D and/or vitamin A palmitate with a carrier consisting of any of the following: butter oil, corn oil, evaporated milk, non-fat dry milk, polysorbate 80, propylene glycol, and glycerol monooleate. It is best to store all concentrates under refrigeration unless manufacturer’s directions indicate otherwise. To achieve adequate dispersion, viscous concentrates should be brought to room temperature before addition.
NEED FOR ADDITION
Vitamin A is fat-soluble. It will dissolve when mixed with fat and will not dissolve in water. For this reason, vitamin A is found in whole milk and to a lesser degree in low fat and absent in non-fat milk, unless these products are fortified.
Vitamin D is the major regulator of calcium absorption in the intestine. Fortification of fresh milk with vitamin D is acknowledged to have virtually eliminated rickets in milk drinking children. Since normal levels of vitamin D are necessary for optimal calcium absorption in children, it is also known that these levels are required as one increases in age. It has been associated with reducing the incidence of osteoporosis in premenopausal women.
Vitamin A performs many functions. One is to enable the retina of the eye to respond to dim light. Deficiency of vitamin A produces night blindness. Vitamin A is also involved in the ability of the eye to discern color.
Excessive levels of vitamins A and D in fluid milk can be a potential threat to public health. Over fortification with levels of vitamin A over 6,000 I.U. and vitamin D over 800 I.U. in fluid milk should be referred to FDA for a health hazard review.
PROBLEMS INVOLVED WITH FORTIFICATION
Milk and milk products that contain a large proportion of fat are relatively good dietary sources of vitamin A, but as is the case with other natural foods, the vitamin D content of unfortified milk is quite low. As with other milk components, vitamin A and D levels are affected by breed, season, diet, lactation, and in the case of vitamin D, animal exposure to sunlight.
In general, when lactating animals are transferred from pasture to winter rations in the fall, a decline in the vitamin A and D levels can be expected in the raw milk. This occurs slowly through the winter season until the animals are once more on pasture in the spring. With the proper selection of feed and diet concentrates, this effect can be kept to a minimum. Natural levels of vitamin A range from 400 I.U. in winter to 1200 I.U. in summer, and vitamin D, 5 I.U. in winter to 40 I.U. in summer. These are approximate ranges to indicate possible seasonal variations. Because of seasonal and other variations in natural vitamin levels, it is necessary to monitor the level of fortification to assure that levels are within good manufacturing practices. Vitamin concentrate potency degrades with time. Concentrates should be stored in accordance with manufacturer's recommendation to maintain label potency. Vitamin concentrate potency should be verified by the vitamin supplier.
Vitamin D is very stable in homogenized whole milk and is not affected by pasteurization or other processing procedures. Vitamin D in fortified homogenized whole milk will remain constant with little or no loss of vitamin potency during long periods of proper storage. No loss of vitamin D will be experienced under normal shelf life periods.
Vitamins A and D fortified skim milk products are subject to decreases in vitamin A, because the vitamin is no longer protected by fat as it is in whole milk. In fluid skim or low fat milk, added vitamin A deteriorates gradually during normal storage of the milk at 4.5°C (40°F) in the dark but is destroyed rapidly when the milk is exposed to sunlight in transparent glass bottles or translucent plastic containers. The photo destruction of added vitamin A is dependent on the intensity and wave-length of light and the milk source. The use of amber or brown glass bottles, pigmented plastic containers formulated with specific light barriers and colored paper cartons retard this destruction. Vitamin A losses in reduced fat milk 2 percent from five (5) dairy plants ranged from 8 percent to 31 percent when they were exposed to 200 foot-candles (220 lux) of fluorescent light for twenty-four (24) hours in opaque plastic containers. Use of pigmented containers or gold shields over fluorescent tubes practically eliminated these losses.
Note: Figure 58 details a two (2) speed vitamin fortification installation using two (2) pumps and two (2) vitamin concentrate sources. This enables changing from different vitamin concentrates and different speed pumps via the adjustment of three-way valves.
Recommendations:
-
Use a sanitary check-valve(s) to separate milklines from vitamin concentrates.
-
All milk or milk product-contact surfaces should be of a sanitary design, easily cleanable, and available for inspection.
Figure 58. Vitamin Fortification
History
- Author: G. M. Gallaspy, Jr.
- Authority: Code of Ala. 1975, §§22-2-2, 22-20-7.
- Repealed and New Rule: Filed October 18, 2018; effective December 2, 2018.
Ala. Admin. Code r. 420-3-16-AP Appendix P - Performance-Based Dairy Farm Inspection System
PREFACE
A performance-based inspection system is an option to the traditional routine inspection frequency of at least once every six (6) months on Grade “A” dairy farms. This option provides Regulatory Agencies with a choice. For some regulatory agencies, inspecting every farm routinely twice a year may provide effective regulatory oversight and make efficient use of inspection resources. For other regulatory agencies, an optional system which determines routine farm inspection frequency based on producer milk quality and inspection performance may be more desirable, equally effective, and make the most efficient use of limited inspection resources. The overall inspection effort devoted to a performance-based farm inspection system may be more or less than the traditional inspection system which requires a routine inspection at least once every six (6) months per farm.
INSPECTION INTERVAL AND CRITERIA
Dairy farms shall be categorized at least every three (3) months using the previous twelve (12) month farm inspection and milk quality data. The following criteria shall be used to categorize farms into four (4) inspection intervals as defined below:
MINIMUM ONE (1) YEAR INSPECTION INTERVAL (ONE [1] INSPECTION EACH TWELVE [12] MONTHS)
All criteria below shall have been met for the previous twelve (12) months:
-
No more than one (1) sample with a SPC >25,000, but less than 100,000.
-
All Somatic Cell Count (SCC) samples ≤ 500,000.
-
No cooling temperature violations.
-
No drug residue violations.
-
No “critical control point” violations observed during farm inspections. Critical violations are identified on Form FDA 2359a-Dairy Farm Inspection Report (FDA 2359a) as:
a. 10-Cleaning and 11-Sanitization.
b. 15(d)-Drugs properly labeled and 15(e)-Drugs properly used and stored.
c. 18-Cooling (Significant Violations).
-
No violation that creates a substantial risk of adulteration or an imminent health hazard.
-
No more than five (5) violations documented on any inspection sheet.
-
No consecutive inspection violations on any inspection item.
-
No record of suspended permit, certification or license due to inspection, milk quality, or drug residue deficiencies.
-
Bacteriologically safe water supply at the time of categorization.
Note: Farms in this category who are re-categorized to a six (6) month inspection interval for a single violation of one (1) milk quality parameter (SCC > 500,000 or cooling temperature violation) may be re-categorized to the one (1) year inspection interval if all ten (10) criteria listed above are met for the next six (6) months.
MINIMUM SIX (6) MONTH INSPECTION INTERVAL (ONE [1] INSPECTION EACH SIX (6) MONTHS)
All criteria below shall have been met for the previous twelve (12) months:
-
May have more than one (1) sample with SPC >25,000.
-
May have one (1) or more SCC sample >500,000.
-
No more than one (1) warning letter issued due to non-compliance of two (2) out of four (4) previous official sample results for SPC and SCC.
-
No cooling temperature violations.
-
No drug residue violations.
-
No "critical control point" violations observed during farm inspections. Critical violations are identified on FDA 2359a as:
a. 10-Cleaning and 11-Sanitization.
15(d)-Drugs properly labeled and 15(e)-Drugs properly used and stored.
b. 18-Cooling (Significant Violations).
-
No violation that creates a substantial risk of adulteration or an imminent health hazard.
-
No more than five (5) violations documented on any inspection sheet.
-
No consecutive inspection violations on any inspection item.
-
No record of suspended permit, certification, or license due to inspection, milk quality, or drug residue deficiencies.
-
Bacteriologically safe water supply at the time of categorization.
Note: Farms meeting the criteria for one (1) year or six (6) month inspection intervals but with less than twelve (12) months of farm inspection and milk quality history, i.e., new farms, shall be assigned to a six (6) month inspection interval.
MINIMUM FOUR (4) MONTH INSPECTION INTERVAL (ONE [1] INSPECTION EACH FOUR [4] MONTHS)
Any criteria listed below results in the farm being placed into this inspection interval for twelve (12) months from the next re-categorization:
-
More than one (1) warning letter issued due to non-compliance of two (2) out of four (4) previous official sample results for SPC and SCC.
-
Farm conditions that caused the Health Officer to take official regulatory action, i.e., warning letter, intent to suspend, re-inspection, etc.
-
One (1) drug residue violation.
-
"Critical control point" violations observed during farm inspections. Critical violations are identified on FDA 2359a as:
a. 10-Cleaning and 11-Sanitization.
b. 15(d)-Drugs properly labeled and 15(e)-Drugs properly used and stored.
c. 18-Cooling (Significant Violations).
-
A violation that creates a substantial risk of adulteration or an imminent health hazard.
-
More than five (5) violations on any inspection.
-
Unsafe water supply at the time of categorization.
MINIMUM THREE (3) MONTH INSPECTION INTERVAL (ONE [1] INSPECTION EACH THREE [3] MONTHS)
Any criteria listed below results in the farm being placed into this inspection interval for twelve (12) months from the next re-categorization:
-
More than one (1) drug residue violation.
-
Any farm suspended from the market by the Health Officer during the previous twelve (12) month evaluation period for any reason other than drug residue violations.
-
More than one (1) incident where violative farm conditions or milk quality parameters resulted in the Health Officer taking official regulatory action, i.e., warning letter, intent to suspend, re-inspection, etc.
Note: The above guidelines for Grade “A” farm inspection intervals are not intended to prevent farm inspections at more frequent intervals, if in the judgment of the Health Officer, more frequent intervals are necessary.
History
- Author: G. M. Gallaspy, Jr
- Authority: Code of Ala. 1975, §§22-2-2, 22-20-7.
- Repealed and New Rule: Filed October 18, 2018; effective December 2, 2018.
Ala. Admin. Code r. 420-3-16-AQ Appendix Q - Operation of Automatic Milking Installations for the Production of Grade "A" Raw Milk for Pasteurization, Ultra- Pasteurization, Aseptic Processing and Packaging or Retort Processed After Packaging
This appendix is intended to clarify how AMIs are to be constructed, installed, perform, monitored, maintained, etc. to be considered in compliance with the Grade "A" PMO. It is formatted to follow the items as outlined in Section 7. STANDARDS FOR GRADE “A” RAW MILK FOR PASTEURIZATION, ASEPTIC PROCESSING AND PACKAGING OR RETORT PROCESSED AFTER PACKAGING. Both requirements and recommendations are provided.
GENERAL REQUIREMENTS FOR AMI COMPUTER SYSTEMS
AMIs have computer systems that are programmed for monitoring and/or controlling various sensors, instrumentation, and the operational state of various devices such as pumps and valves; have data collection, storage, and reporting systems; and have communication network capabilities for multiple uses and locations. While electronic and computer systems can furnish a wide range of process verification and anomaly reporting, these are criteria only for compliance with Items 1r, 13r, and 14r.
The dairy farm shall have an identified representative(s) that has been trained by the AMI manufacturer or AMI manufacturer’s designated representative to make program changes to the AMI system.
A manufacturer’s written or electronic documentation addressing the computer system’s monitoring and controlling functions related to Items 1r, 13r, and 14r shall explain the devices controlled, the sensors or instruments monitored, and testing procedures. A document shall bear the name of the identified representative of the dairy farm and shall be available for review at the dairy farm upon request by the regulatory agency, rating agency and/or the FDA.
This documentation shall address Items 1r, 13r, and 14r:
-
The software version used, the devices controlled or monitored and their locations, and the sensors or instruments monitored and their locations.
-
The testing procedures for all of the computer system’s controlled and monitoring devices.
-
The procedure for any changes or maintenance to the computers, devices, instrumentation, sensors hardware, etc.
-
Instructions on how to access the information available on the computer system.
Note: Controls for the devices are verified as directed by the regulatory agency.
The data supporting the electronic reports shall be stored in a database or data archival system. Written or electronic record(s) shall be maintained at the dairy farm identifying changes and verifying compliance with this rule. This record shall contain the name of the identified dairy farm representative assigned to administer the computer system and these record(s) shall be available for review at the dairy farm upon request by the regulatory agency, rating agency and/or the FDA.
A verification of all computer system’s controlled functions shall be conducted and documented at the commissioning of the computer system and at additional frequencies as deemed necessary by the regulatory agency. Computer system controlled functions should be reviewed and verified by the regulatory agency during routine dairy farm inspections and by the rating agency and the FDA.
ITEM 1r. ABNORMAL MILK
AMIs shall have the capability to identify and discard milk from animals that are producing milk with abnormalities. Odor is currently evaluated on a farm bulk milk tank/silo basis and shall not be any different for a herd using AMI technology.
The dairy farm shall have a documented procedure in place describing how abnormal milk is properly detected and diverted; and that equipment used for the milking of healthy animals has not become contaminated. The procedure shall also document that a physical change to the AMI system has occurred.
A verification of all computer system’s controlled functions responsible for properly detecting and diverting abnormal milk shall be conducted and documented at the commissioning of the computer system. This verification means the visual observation by regulatory agency personnel; or documentation indicating the testing that was completed by an AMI manufacturer’s designated representative; or other means accepted by the regulatory agency. Written or electronic information for all required actions shall be maintained at the dairy farm and shall be made available upon request to the regulatory agency, rating agency, and/or the FDA.
Animals producing milk with abnormalities shall be diverted to a holding pen to be milked immediately prior to the milking system being cleaned and sanitized, or the animal(s) are identified through an appropriate identification system so that their milk will be automatically excluded from the milk offered for sale, provided that the parts of the milking system that came into contact with the milk with abnormalities are immediately cleaned and sanitized.
ITEM 2r. MILKING BARN, STABLE, OR PARLOR - CONSTRUCTION
The AMI milker box shall be treated the same as any other milking parlor. The goal is a clean environment in which to milk animals. All ventilation air shall come from outside the cattle housing area. The AMI should be located to provide a clean access for all personnel.
ITEM 3r. MILKING BARN, STABLE, OR PARLOR – CLEANLINESS
The AMI milker box shall be kept as clean as any milking and equipment cleaning area. It is recommended that the milking platform be regularly flushed with water to remove any manure that may have accumulated.
ITEM 9r. UTENSILS AND EQUIPMENT - CONSTRUCTION
AMIs are the same as any other milking system from a sanitary construction and installation standpoint and shall meet the same standards as a conventional milking system in respect to construction, installation, inspectability, the fit and finish of the milk product-contact surfaces, etc.
ITEM 10r. UTENSILS AND EQUIPMENT – CLEANING
AMIs are a continuous milking system and shall be shut down to clean at an interval sufficient to prevent the milking system from building up with soils. It is recommended that this interval not to exceed eight (8) hours.
ITEM 11r. UTENSILS AND EQUIPMENT – SANITIZATION
AMIs shall be sanitized after each cleaning and/or before each use, as is the case with any other milking system.
ITEM 12r. UTENSILS AND EQUIPMENT – STORAGE
AMIs shall have positive air ventilation systems in operation whenever the milking system is being cleaned and/or sanitized. The air for this ventilation system shall come from outside the cattle housing area and shall be as clean and dry as practical. This positive air ventilation system shall also run during milking if needed to minimize odors, moisture, and/or for pest control.
ITEM 13r. MILKING - FLANKS, UDDERS, AND TEATS
AMI manufacturers shall submit data to the FDA to show that the teat prepping system employed in their milking system is equivalent to Item 13r., Administrative Procedures 4 of these rules: “Teats shall be treated with a sanitizing solution just prior to the time of milking and shall be dry before milking.” Each AMI installer shall provide the dairy producer and the Health Officer with a copy of this FDA acceptance, including a detailed description of the accepted equivalent procedure. Each dairy producer shall keep a copy of the accepted teat prep protocol along with the appropriate AMI manufacturer’s teat prep protocol verification procedures on file at the dairy farm.
A verification of all computer system’s controlled functions responsible for proper teat preparation shall be conducted and documented at the commissioning of the computer system. This verification means the visual observation by regulatory agency personnel; or documentation indicating the testing that was completed by an AMI manufacturer’s designated representative; or other means accepted by the regulatory agency. Written or electronic information for all required actions shall be maintained at the dairy farm and shall be made available upon request to the regulatory agency, rating agency, and/or the FDA.
ITEM 14r. PROTECTION FROM CONTAMINATION
The teat cups (inflations) of the milking cluster shall be adequately shielded, or variations may be individually evaluated and found to also be acceptable by the FDA and the Health Officer, during the teat prepping process to assure that contaminants shall not enter through the teat cups and get into the milk.
AMIs are designed to automatically shift from milking to cleaning/sanitizing positions; therefore, adequate separation of milk and CIP solution shall be provided to minimize the risk of cross contamination of milk with cleaning and/or sanitizing solutions. A fail-safe valve system providing protection equivalent to an inter-wired block-and-bleed valve arrangement, as referenced in Item 14r of these rules, shall be located as needed to prevent cross contamination. Separation shall be provided between milk with abnormalities and milk intended for sale, and between cleaning/sanitizing solutions and milk intended for sale.
Each dairy producer shall keep a copy of the AMI manufacturer’s testing verification procedures for the fail-safe valve systems on file at the dairy farm.
AMIs which have a wash line extending into the wash vat that is continuously connected to the milking system shall have a valving arrangement that provides for an air break equal to the diameter of the wash line.
ITEM 18r. RAW MILK COOLING
For AMIs, the raw milk for pasteurization, ultra-pasteurization, aseptic processing, and packaging or retort processed after packaging shall be cooled to 10°C (50°F) within four (4) hours or less after starting the milking operation and the milk shall be cooled within two (2) more hours to 7°C (45°F). The milk in the farm bulk milk tank/silo shall not exceed 7°C (45°F) after that time. Farm bulk milk tank/silo recording thermometers are recommended if not already required by these rules.
History
- Author: G. M. Gallaspy, Jr.
- Authority: Code of Ala. 1975, §§22-2-2, 22-20-7.
- Repealed and New Rule: Filed October 18, 2018; effective December 2, 2018.
Ala. Admin. Code r. 420-3-16-AR Appendix R - Determination of Time/Temperature Control for Safety Milk and/or Milk Products
The Institute of Food Technologists (IFT) prepared and submitted a report as part of a contract with the FDA that contains responses to various questions posed by the FDA about potentially hazardous food (PHF). IFT reviewed the evolution of the term PHF and recommended a change to time/temperature control for safety (TCS) food, as well as a science-based framework for determining the effectiveness of processing technologies that formulate a food.
The report examines intrinsic factors such as aw, pH, redox potential, natural, and added antimicrobial and competitive microorganisms; and extrinsic factors such as packaging, atmospheres, storage conditions, processing steps, and new preservation technologies that influence microbial growth. The report also analyzes microbial hazards related to time/temperature control of foods for safety.
IFT developed a framework that could be used to determine whether a food is a TCS or not. Part of the framework, applicable to Grade “A” milk and milk products includes two tables that consider the interaction of pH and aw in milk and milk products, whether the milk or milk product is pasteurized and subsequently packaged (Table A), or not pasteurized or pasteurized but not packaged (Table B). When further product assessment (PA) is required, the application of microbiological challenge testing (inoculation studies) is discussed along with pathogen modeling programs and reformulation of the milk and/or milk product. An extensive reference list is included in the report.
TCS food is defined in terms of whether or not it requires time/temperature control for safety to limit pathogen growth or toxin formation. The definition does not address foods that do not support growth but may contain a pathogenic microorganism or chemical or physical food safety hazard at a level sufficient to cause foodborne illness or injury. The progressive growth of all foodborne pathogens is considered whether slow or rapid.
The definition of TCS takes into consideration aw, pH, aw and pH interaction, pasteurization, and subsequent packaging for a relatively simple determination of whether the food requires time/temperature control for safety. If a milk or milk product is pasteurized to eliminate pathogenic vegetative cells, it needs to be addressed differently than a raw product or a raw product subjected to inadequate heating. In addition, if a milk or milk product is packaged after pasteurization to prevent re-contamination, higher ranges of pH and/or aw can be tolerated because spore-forming bacteria are the only microbial hazards of concern. Milk and milk products shall be protected from contamination in an area with limited access and packaged at a temperature in compliance with the Grade “A” PMO requirements. In some milk or milk products, it is possible that neither the pH value nor the aw value is low enough by itself to control or eliminate pathogen growth; however, the interaction of pH and aw may be able to accomplish it. This is an example of a hurdle technology. Hurdle technology is utilized when several inhibitory factors are used together to control or eliminate pathogen growth that would otherwise be ineffective when used alone.
Another important factor to consider is combination products. A combination product is one (1) in which there are two (2) or more distinct food components, and an interface between the two (2) components may have a different property than either of the components present. Determine whether the food has distinct components such as cottage cheese curd with fruits and/or vegetables to be added and the creaming mixture, or does it have a uniform consistency such as the cottage cheese creaming mixture or plain yogurt. In these products, the pH at the interface is important in determining if the item is a TCS milk or milk product.
Appropriate evidence acceptable to FDA such as other published scientific research and/or an inoculation study should be used to determine whether a food can be held without time/temperature control when:
-
Combination products are prepared; or
-
Other extrinsic factors (packaging/atmospheres) or intrinsic factors (redox potential, salt content, antimicrobials, etc.) found in the food are used to control or eliminate pathogen growth.
Before using Tables A and B, which are included in the definition of Time/Temperature Control for Safety of Milk and/or Milk Products of these rules, in determining whether a milk or milk product requires TCS, answers to the following questions should be considered:
-
Is the intent to hold the milk or milk product without using time or temperature control? If the answer is “No”, no further action is required. The decision tree is not needed to determine if the item is a TCS milk or milk product.
-
Is the milk or milk product raw or heat-treated, or is the milk or milk product pasteurized?
-
Does the Grade “A” PMO already require TCS for the milk or milk product?
-
Does a product history with good scientific rationale exist indicating a safe history of use?
-
Is the milk and/or milk product processed and packaged so that it does not require TCS; such as aseptically processed and packaged Grade “A” low-acid milk and/or milk products and/or retort processed after packaged Grade “A” low-acid milk and/or milk products?
-
What is the aw and pH of the milk or milk product in question using laboratory results accepted by FDA.
A milk or milk product designated PA (further product assessment required) in either Table A or B should be considered TCS until sufficient information is provided to demonstrate the safety of the product. The PA shall be an evaluation of the milk or milk product group’s ability to not support pathogenic growth. Means to evaluate this assessment include (but are not limited to): literature review of similar milk products, inoculation studies, expert risk assessment, and/or Health Officer assessment.
A milk or milk product designated PA (further product assessment required) in either Table A or B should be considered TCS until sufficient information is provided to demonstrate the safety of the product. The PA will be an evaluation of the product or product group’s ability to not support pathogenic growth. Means to evaluate this assessment include (but are not limited to): literature review of similar products, inoculation studies, expert risk assessment, and/or state regulatory assessment.
INSTRUCTIONS FOR USING TABLES A AND B
- Does the operator want to hold the milk or milk product without using time or temperature control?
a. No: Continue holding the milk or milk product at 7°C (45°F) or less as required in the Grade “A” PMO.
b. Yes: Continue using the decision tree to identify which table to use to determine whether TCS is required.
- Is the milk or milk product pasteurized?
a. No: The milk or milk product is either raw or heat-treated. Proceed to Step 3.
b. Yes: The milk or milk product is pasteurized to the required minimum time and temperature for the milk or milk product as specified in the definition of pasteurization of these rules. Proceed to Step 4.
- Is the milk or milk product treated using some other method equivalent to pasteurization?
a. No: The milk or milk product is raw or heat-treated which may allow vegetative cells and spores to survive. Proceed to Step 6.
b. Yes: If another method equivalent to pasteurization is used to destroy pathogens such as irradiation, high pressure processing, pulsed light, ultrasound, inductive heating, etc., the new technology shall have been recognized by the FDA as providing milk or milk product safety equal to pasteurization, and the effectiveness of the process shall be demonstrated by sufficient evidence or other means proceed to Step 5.
- Is it packaged to prevent re-contamination?
a. No: Re-contamination of the product can occur after pasteurization because it is not immediately packaged. Proceed to Step 6 and use Table B.
b. Yes: If the milk or milk product is packaged immediately after pasteurization to prevent re-contamination, higher ranges of aw and/or pH can be tolerated because spore-forming bacteria are the only microbial hazard. Proceed to Step 6 and use Table A.
- Further PA or plant documentation required.
a. The manufacturer of this product may be able to supply evidence acceptable to the FDA that indicate the milk or milk product can be safely held without TCS.
b. Milk and milk products prepared or processed using new technologies may be held without time/temperature control provided the new technology has been recognized by the FDA as providing milk or milk product safety equal to pasteurization and provided the effectiveness of the use of such technologies is based on evidence accepted by the FDA.
- Using the milk or milk product’s processing parameters, known aw and/or pH values, position the milk or milk product in the appropriate table.
a. Choose the column under “pH Values” that contains the pH value of the milk or milk product in question.
b. Choose the row under “aw Values” that contains the aw value of the milk or milk product in question.
c. Note where the row and column intersect to identify whether the milk or milk product is Non-TCS and therefore does not require time/temperature control, or whether further PA is required. Other factors such as redox potential, competitive microorganisms, salt content, or processing methods may allow the product to be held without time/temperature control; however, evidence acceptable to the FDA is required.
-
Use Table B for milk or milk products that are not pasteurized or pasteurized but not immediately packaged, where both pathogenic spores and vegetative cells may be a concern, or use Table A for milk and milk products that are pasteurized and immediately packaged, where only pathogenic spores are of concern.
-
Determine if the milk or milk product is Non-TCS or needs further PA.
Figure 59. Decision Tree for Using pH, aw, or the Interaction of pH and aw to Determine if a Milk or Milk Product Requires Time/Temperature for Safety
Source Document: Evaluation and Definition of Potentially Hazardous Foods, IFT, 2001 available at http://www.fda.gov/-comm/ift4exec.html.
History
- Author: G. M. Gallaspy, Jr.
- Authority: Code of Ala. 1975, §§22-2-2, 22-20-7.
- Repealed and New Rule: Filed October 18, 2018; effective December 2, 2018.
Ala. Admin. Code r. 420-3-16-AS Appendix S - Aseptic Processing and Packaging Program and Retort Processed After Packaging Program
The Aseptic Processing and Packaging Program is designed to include all Grade “A” low-acid (21 CFR Part 113) aseptically processed and packaged milk and/or milk products.
The Retort Processed after Packaging Program is designed to include all Grade “A” low-acid (21 CFR Part 113) retort processed after packaged milk and/or milk products.
Note: Retort processed after packaging low-acid milk and/or milk products as addressed in the definition of Milk Products of these rules shall be considered to be Grade "A" milk and/or milk products if they are used as an ingredient to produce any milk and/or milk product defined in the definition of milk products of these rules or if they are labeled as Grade “A” as described in Section 4 of these rules.
Inspections of a milk plant or portion of a milk plant that is IMS listed to produce aseptically processed and packaged low-acid milk and/or milk products and/or retort processed after packaged low-acid milk and/or milk products shall be conducted by the Health Officer in accordance with these rules and the information provided below at least once every six (6) months. The milk plant’s APPS or RPPS, respectively, as defined by these rules, shall be exempt from Items 7p, 10p, 11p, 12p, 13p, 15p, 16p, 17p, 18p, and 19p of these rules and shall comply with the applicable portions of 21 CFR Parts 108, 110, and 113. The milk plant's APPS and/or RPPS, respectively, shall be inspected by the FDA, or the State Health Officer when designated by the FDA, in accordance with the applicable requirements of 21 CFR Parts 108, 110, and 113 at a frequency determined by FDA.
When the APPS, as defined by these rules, is utilized to produce aseptically processed and packaged low-acid milk and/or milk products and pasteurized and/or ultra-pasteurized milk and/or milk products, the APPS shall be inspected and tested by the Health Officer in accordance with the requirements cited in Section 7 of these rules.
ASEPTIC PROCESSING AND PACKAGING PROGRAM AND RETORT PROCESSED AFTER PACKAGING PROGRAM CFR/GRADE "A" PMO COMPARISON SUMMARY REFERENCE
| PMO, Section 7 Items | Aseptic Program/Retort Program | Authority | | --- | --- | --- | | 1p. Floors – Construction | Floor drains are not required in storage rooms for aseptic processed and packaged low-acid milk and/or milk products and retort processed after packaged low-acid milk and/or milk products. | PMO | | 2p. Walls and Ceiling - Construction | Ceiling requirements are exempt in aseptically processed and packaged low-acid milk and/or milk products and retort processed after packaged low-acid milk and/or milk products dry storage rooms. (Same as for dry milk or milk products.) | PMO | | 3p. Doors and Windows | None | PMO | | 4p. Lighting and | None | PMO | | 5p. Separate Rooms | Fabrication of containers and closures for aseptic processed and packaged low-acid milk and/or milk products and retort processed after packaged low-acid milk and/or milk products within the APPS and/or RPPS, respectively, is exempt. | PMO | | 6p. Toilet – Sewage Disposal | None | PMO | | 7p. Water Supply* | The APPS and/or RPPS, respectively, is exempt, but shall comply with the CFR. | PMO/CFR | | 8p. Handwashing Facilities | None | PMO | | 9p. Milk Plant Cleanliness | None | PMO | | 10p. Sanitary Piping* | The APPS and/or RPPS, respectively, is exempt, but shall comply with the CFR. | PMO/CFR | | 11p. Construction and Repair of Containers and Equipment* | The APPS and/or RPPS, respectively, is exempt, but shall comply with the CFR. Paper, plastics, foil, adhesives, and other components of containers and closures used in the packaging of milk and/or milk products that have been aseptically processed and packaged or retort processed after packaged are not required to comply with Appendix J of the PMO; are not required to originate from an IMS Listed Source; and are subject to the requirements of the CFR. | PMO/CFR | | 12p. Cleaning and Sanitizing of Containers and Equipment* | The APPS and/or RPPS, respectively, is exempt, but shall comply with the CFR. | PMO/CFR | | 13p. Storage of Cleaned Containers and Equipment* | The APPS and/or RPPS, respectively, is exempt, but shall comply with the CFR. | PMO/CFR | | 14p. Storage of Single-Service Containers, Utensils, and Materials | None | PMO | | 15p.(A) Protection from Contamination* | The APPS and/or RPPS, respectively, is exempt, but shall comply with the CFR. | PMO/CFR | | 15p.(B) Protection from Contamination - Cross Connections* | The APPS and/or RPPS, respectively, is exempt, but shall comply with the CFR. APPS and/or RPPS equipment is exempt from the separation requirements of the PMO in relationship to instrumented steam blocks between milk and milk products and cleaning and/or chemical sanitizing solutions. | PMO/CFR | | 16p. Pasteurization and Aseptic Processing and Packaging (A) through (D)* | The APPS and/or RPPS, respectively, is exempt, but shall comply with the CFR. The Health Officer is not required to conduct the quarterly equipment testing and sealing of aseptic and/or processing equipment. Records and recording charts are not required to be reviewed during routine inspections, ratings or check ratings. | CFR | | 17p. Cooling of Milk and Milk Products* | The APPS and/or RPPS, respectively; aseptic processed and packaged low-acid milk and/or milk product storage; and retort processed after packed low-acid milk and/or milk product storage is exempt, but shall comply with the CFR. | PMO/CFR | | 18p. Bottling, Packaging, and | The APPS and/or RPPS, respectively, is exempt, but shall comply with the CFR. | CFR | | 19p. Capping, Container Closure, and Sealing and Dry Milk Product Storage* | The APPS and/or RPPS, respectively, is exempt, but shall comply with the CFR. | CFR | | 20p. Personnel-Cleanliness | None | PMO | | 21p. Vehicles | None | PMO | | 22p. Surroundings | None | PMO |
*Note: In areas of the milk plant where these items are dedicated only to the APPS and/or RPPS, respectively, as defined by these rules, these Items shall be inspected and regulated in accordance with the applicable FDA regulations (21 CFR Parts 108, 110, and 113).
History
- Author: G. M. Gallaspy, Jr.
- Authority: Code of Ala. 1975, §§22-2-2, 22-20-7.
- Repealed and New Rule: Filed October 18, 2018; effective December 2, 2018.
Continue your research in ChatGPT or Claude
Connect Omnilex to search the legal corpus from your AI assistant.